• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
SIPROTEC 4 7SJ63 Multifunction Protection Relay
SIPROTEC 4 7SJ63 Multifunction Protection Relay

... When the high-impedance measurement principle is applied, all current transformers in the protected area are connected in parallel and operated on one common resistor of relatively high R whose voltage is measured (see Fig. 5/115). In the case of 7SJ6 units, the voltage is measured by detecting the ...
Standard Control Options
Standard Control Options

High-Voltage, Linear High-Brightness LED Driver with Open-LED Fault Detect MAX16839 General Description
High-Voltage, Linear High-Brightness LED Driver with Open-LED Fault Detect MAX16839 General Description

... detected, a 2.8mA current source charges the capacitor between FLTS and ground, up to 15V or to VIN if VIN is less than 15V. If the voltage on FLTS is greater than 1.65V due to the charge retained in the FLTS capacitor, the LED driver is turned off. This provides an open-LED fault-protection feature ...
LIGHTNING IMPULSE TESTS ON AIR
LIGHTNING IMPULSE TESTS ON AIR

Chapter 5 Protection Circuit Design
Chapter 5 Protection Circuit Design

Application Note No. 101
Application Note No. 101

... variations in diode forward voltages VF from one stack to the next. One way to view the situation is as follows: a voltage source (e.g. a standard power supply with low output impedance) in series with a sufficiently high resistance approximates an ideal current source, e.g. the resistor helps to gi ...
Data Sheet
Data Sheet

BD1321G
BD1321G

... (Note 3) The voltage difference between inverting input and non-inverting input is the differential input voltage. Then input terminal voltage is set to more than VSS. (Note 4) An excessive input current will flow when input voltages of more than VDD+0.6V or less than VSS-0.6V are applied. The input ...
MAX8543/MAX8544 Step-Down Controllers with Prebias Startup, Lossless Sensing, Synchronization, and OVP General Description
MAX8543/MAX8544 Step-Down Controllers with Prebias Startup, Lossless Sensing, Synchronization, and OVP General Description

... The MAX8543/MAX8544 current-mode, constant-frequency PWM buck controllers operate from a 3V to 13.2V input supply and generate adjustable 0.8V to 0.9 x VIN output voltages at loads up to 25A. They feature adjustable switching frequency and synchronization for noise-sensitive applications. The MAX854 ...
LM78S40 Switching Voltage Regulator Applications
LM78S40 Switching Voltage Regulator Applications

SE-325 Manual
SE-325 Manual

... voltages up to 5 kV with NGR let-through currents of 5 A or less. Occasionally, alarm-only systems up to 15 kV and up to 10 A are used; however, they are not common because a ground fault on such a system tends to escalate to a phase-to-phase fault before the ground fault can be located and cleared. ...
Pluto Servo Drive Product Manual v.6
Pluto Servo Drive Product Manual v.6

... The Pluto Servo Drive components temperature may exceed 100 ºC during operation. Some components become electrically charged when in operation. The power supply connected to this controller should comply with the parameters specified in this document. When connecting the Pluto Servo Drive to an appr ...
Comparative Analysis Of Current Control Methods For Modular
Comparative Analysis Of Current Control Methods For Modular

... independently to N+1 discrete voltage levels. Zero volts is included as a level; thus, the MMC naming convention is that of an (N+1)-level converter. If a higher number of submodules is used, a higher quality voltage waveform can be produced because of the ability to adjust the output by smaller vol ...
PAM2306 Description Features Pin Assignments Applications
PAM2306 Description Features Pin Assignments Applications

... This formula has a maximum at VIN = 2VOUT, where IRMS = IOUT /2. This simple worst-case condition is commonly used for design because even significant deviations do not offer much relief. Note that the capacitor manufacturer's ripple current ratings are often based on 2000 hours of life. This makes ...
NCP1070, NCP1071, NCP1072, NCP1075, NCP1076, NCP1077 High-Voltage Switcher for
NCP1070, NCP1071, NCP1072, NCP1075, NCP1076, NCP1077 High-Voltage Switcher for

... The NCP107x offers a complete current−mode control solution. The component integrates everything needed to build a rugged and low−cost Switch−Mode Power Supply (SMPS) featuring low standby power. The Quick Selection Table on page 2 details the differences between references, mainly peak current setp ...
Instrument Transformers
Instrument Transformers

and Dual-Channel Antenna LDO With Current
and Dual-Channel Antenna LDO With Current

... The accurate current sense allows detection of open, normal, and short-circuit conditions without the need for further calibration. Current sense can be multiplexed between channels and devices to save ADC resources. Each channel also implements adjustable current limit with an external resistor. Th ...
DC MachinesPPT1 - Electrical and Computer Engineering
DC MachinesPPT1 - Electrical and Computer Engineering

...  For the current-carrying conductor shown in Fig.3.3(a), the force (known as Lorentz force) produced on the conductor can be determined from the following ...
PAM2863 Description Pin Assignments
PAM2863 Description Pin Assignments

BD60A00NUX
BD60A00NUX

... ① Input each control signal after VIN exceeds 2.2V and UVLO is off. ② When input Enable and PWM, the standup time should be placed as Min.100µs from 2.2V to stable voltage for VIN. ③ Since a soft start function stops working at the time of following PWM=H when EN=H is held with PWM=L. After EN=H sho ...
General Description Features and Benefits
General Description Features and Benefits

LM2676 - Texas Instruments
LM2676 - Texas Instruments

... Simple-to-Design, High Efficiency (>90%) StepDown Switching Regulators Efficient System Preregulator for Linear Voltage Regulators Battery Chargers ...
ZXLD1360 Description Pin Assignments Features Typical
ZXLD1360 Description Pin Assignments Features Typical

DC-DC Power Converters
DC-DC Power Converters

Designing Single phase inverter - Faculty of Engineering - An
Designing Single phase inverter - Faculty of Engineering - An

... Program PIC C was used to write the PICs codes. The PICs codes are attached in appendix (A). ...
< 1 ... 57 58 59 60 61 62 63 64 65 ... 489 >

Stepper motor



A stepper motor or step motor or stepping motor is a brushless DC electric motor that divides a full rotation into a number of equal steps. The motor's position can then be commanded to move and hold at one of these steps without any feedback sensor (an open-loop controller), as long as the motor is carefully sized to the application in respect to torque and speed.Switched reluctance motors are very large stepping motors with a reduced pole count, and generally are closed-loop commutated.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report