• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Exp-1 - WordPress.com
Exp-1 - WordPress.com

... resistance could be changed to zero, we could get a maximum phase angle of 90 degrees. But since a voltage cannot be developed across zero resistance, a 90-degree phase shift is not possible. With a small value of resistance the achieved phase shift is less than 90 degrees, but in the phase-shift os ...
Dynamic Resistance
Dynamic Resistance

... In a standard power supply that regulates output voltage the load resistance has a simple calculation: RO = VO / IO LEDs are PN junction diodes with a dynamic resistance that shifts as their forward current changes. When the load is an LED or string of LEDs, the load resistance is replaced with the ...
Rod Control System Load Resistor Kits Nuclear Automation Background
Rod Control System Load Resistor Kits Nuclear Automation Background

... In 1969, the first solid state rod control system was installed in a U.S. nuclear power plant. Over the years, some sites have reported issues with the power supplies used in these systems. Specifically, the Lambda power supplies in the rod control systems have failed internally without causing enou ...
Full-text
Full-text

... of theses three periods the direction of the magnetic flux changes for 360 electric degrees, but the rotor turns for 1800. The next three periods (6 half-periods) a voltage connects sequence: A – C` - B – A` - C – B`, and the magnetic field and also rotor rotate in the opposite direction. In the tim ...
Glossary of Terms - Advanced Protection Technologies
Glossary of Terms - Advanced Protection Technologies

BASIC ELECTRONIC COMPONENTS
BASIC ELECTRONIC COMPONENTS

... Types: There are two types of standard transistors, NPN and PNP, with different circuit symbols. The letters refer to the layers of semiconductor material used to make the transistor. Most transistors used today are NPN because this is the easiest type to make from silicon. The leads are labeled bas ...
350 kVA - 505 Amps per phase
350 kVA - 505 Amps per phase

... caused, for example, by short circuit or out-of-phase paralleling. The SX440 will support a range of electronic accessories, including a 'droop' Current Transformer (CT) to permit parallel operation with other ac generators. If 3-phase sensing is required with the self-excited system, the SX421 AVR ...
MIL-STD-883H METHOD 3020 HIGH IMPEDANCE (OFF
MIL-STD-883H METHOD 3020 HIGH IMPEDANCE (OFF

... 1. PURPOSE. This method establishes the means for assuring circuit performance to the limits specified in the applicable acquisition document in regard to output leakage current when an output is in the high-impedance state with a low-level voltage applied. This current should normally be specified ...
High Voltage Engineering
High Voltage Engineering

... Testing of overhead line insulators, cables, bushings, capacitors, transformers, circuit breakers, test voltage Non-destructive insulation test techniques Loss in dielectric, Measurement of resistivity, dielectric constant and loss factor, high voltage scherring bridge, measurement of large capacita ...
DE-ACCM5G - Dimension Engineering
DE-ACCM5G - Dimension Engineering



Model Question Paper BASIC ELECTRICAL ENGINEERING
Model Question Paper BASIC ELECTRICAL ENGINEERING

A transformer is a device that transfers electrical energy from
A transformer is a device that transfers electrical energy from

... noise from or to ground electronic circuits. Since a transformer cannot pass DC voltage from primary to secondary, any DC voltage (such as noise) cannot be passed, and the transformer acts to isolate this noise. F The ....................................................... (PT) steps down voltage of ...
New SOT Package Supervisors
New SOT Package Supervisors

... High accuracy 0.4V(±1.5%) threshold enables monitoring of core supplies <1.2V Output valid to 0.9V ensures clean power down Preset threshold in 100mV increments from 2.5-5.0V Pin to pin to MAX6305/6 with higher spec. 5 Lead SOT23 package saves board space ...
M045037985
M045037985

... electric vehicles as it has more advantages over induction motors because it has permanent magnets in rotor assembly generates steady magnetic field. The multilevel inverters are preferred over conventional inverters as the voltage stress across each semiconductor switches is the voltage of one capa ...
Test Procedure for the NCP690, 1A, Adjustable LDO  Test Setup:
Test Procedure for the NCP690, 1A, Adjustable LDO Test Setup:

... R1, R2 - Feedback Resistors required to set the Output Voltage. Test Procedure: The feedback resistors R1 and R2 have to be soldered before any measurement could be started (Figure 1). Please use the following equation to determine the appropriate value of feedback resistors to be soldered on the ...
the electric force of a current: weber and the surface charge of
the electric force of a current: weber and the surface charge of

... In the past, many authors, including prominent physicists, held incorrect points of view regarding steady currents and some still do in recent years. The problem seems to stem from the fact that the frame of reference is rigidly chosen as an inertial frame of reference, say, the current carrying wir ...
Barzyk, Dopiera: Significant
Barzyk, Dopiera: Significant

ECE 241L_lab5_old
ECE 241L_lab5_old

Lets start with the step
Lets start with the step

... power brick which charges your laptop. There is one for almost every electronic household device – be it external as an adapter or internal as part of the device itself. ...
Battery Charge Regulator for a photovoltaic power system using
Battery Charge Regulator for a photovoltaic power system using

... It is the first time we learnt about its major stages. it is the first time that we deal with transformer in these details . we have studied the rectifiers in Power Electronics course but it is the first time we see the output at the oslliscope by our work. we notice what useful we get from using a ...
Improved Phase Shedding Techniques in Interleaved Converters
Improved Phase Shedding Techniques in Interleaved Converters

... complicated. Definite controls for detecting the point where current crosses 0 and the point where current reaches the average value need to be defined. Doing so may prove to be cumbersome in analog domain or rather the simulink domain. Hence state machine diagrams are used for implementing this con ...
Managed Rack PDU - AutoCont Control System
Managed Rack PDU - AutoCont Control System

Quotations - School Of Engineering
Quotations - School Of Engineering

... lower in the specimen. With a calibrated torsion spring to give a rotation of 0.1º/ sec, Rate of rotation 1/60rpm, Vane as per IS, suitable for operation on 220V , 50Hz, single phase AC supply. Graduate dial to measure angle of torque. Pavement intensity test apparatus - Digital type with load cells ...
For those who want to break into the field of power quality, the Fluke
For those who want to break into the field of power quality, the Fluke

... Return to the menu screen and select the Power function. Notice that the analyzer has the capability of measuring either single-phase or three-phase power. If three-phase power is selected, the instrument shows how to connect test leads for such measurements. The Power screen also displays the volta ...
< 1 ... 968 969 970 971 972 973 974 975 976 ... 1089 >

Three-phase electric power



Three-phase electric power is a common method of alternating-current electric power generation, transmission, and distribution. It is a type of polyphase system and is the most common method used by electrical grids worldwide to transfer power. It is also used to power large motors and other heavy loads. A three-phase system is usually more economical than an equivalent single-phase or two-phase system at the same line to ground voltage because it uses less conductor material to transmit electrical power.The three-phase system was independently invented by Galileo Ferraris, Mikhail Dolivo-Dobrovolsky, Jonas Wenström and Nikola Tesla in the late 1880s.