• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Circuit Analysis
Circuit Analysis

... II. The Digital Multimeter (DMM) The DMM is a powerful tool that can make many kinds of measurements. We will be measuring potential difference or voltage in this activity. Move the selector to 20 V (or 200 V). Switch from Alternating Current to Direct Current ...
Chapter 27 QQ
Chapter 27 QQ

2 marks EC2201
2 marks EC2201

MASTER SYLLABUS 2014-2015 A. Academic Division: Business
MASTER SYLLABUS 2014-2015 A. Academic Division: Business

... RMS values of voltage and current of an AC sine wave using both digital and analog multimeters or clip-on ammeters. Safely measure AC sine wave voltages and phase shifts of voltage and current in RLC circuits on an oscilloscope. Compute the peak voltage, peak-peak voltage, RMS voltage, frequency and ...
Power System Fundamentals
Power System Fundamentals

DSL  Primary Switched Battery Charging and Power Supply Unit GL1024
DSL Primary Switched Battery Charging and Power Supply Unit GL1024

... The battery charging and power supply unit GL1024 is used for charging high-quality lead or nickel-cadmium batteries and/or for supplying 24V DC circuits. The charging unit is especially suitable for use with diesel generators, where operating safety and long-term stability are necessary. The primar ...
Simple, Efficient, High- Brightness-LED Control
Simple, Efficient, High- Brightness-LED Control

... slightly asymmetrical tolerance allows a 18%, +20% variation in the device’s forward voltage at 700 mA. The VF also varies over temperature, with a negative temperature coefficient of -2mV/C. At 100C, this is another 0.15V voltage change. Typical strings of multiple LEDs further magnify these variat ...
PDA
PDA

... for the controller, the voltage obtained from battery needs another treatment. The conventional method is to boost the battery voltage and then reduce it to what we expect. In this manner, regulated voltages are obtained from the battery steadily, regardless of the original level of the battery. ...
A Solution to Simplify 60A Multiphase Designs
A Solution to Simplify 60A Multiphase Designs

... IC have been matched to provide the cleanest and fastest switching possible. Because the traces between them are very small, the stray inductances and capacitive elements on the path from the gate driver to the MOSFET gate are also minimized. This in itself can offer up to 2% efficiency gain at 300k ...
Guidance On Electrical Installation Practices To Reduce EMF From
Guidance On Electrical Installation Practices To Reduce EMF From

... as workstations, a distance of 4 to 5 metres from switchrooms is suggested to provide the additional benefit of avoiding computer monitor interference for old style CRT monitors. • In schools, childcare facilities or similar sensitive premises, install switchboards well away from classrooms and area ...
Effect of harmonics on current ratings and voltage drop
Effect of harmonics on current ratings and voltage drop

... harmonic currents. Multiplying the 50 Hz conductor resistance by the appropriate factor, Cr, from the above table will give the resistance at that frequency. If Cr x Rf is substituted for Rh in equation 2 it is clear that Rf will cancel in the numerator and the denominator. Thus the factors given in ...
Space Vecor Modulated Three Level Neutral Point Clamped Inverter
Space Vecor Modulated Three Level Neutral Point Clamped Inverter

... The vectors are called the basic space vectors which are mentioned by V0, V1, V2, V3, V4, V5, V6, and V7. The same transformation can be applied to the desired output voltage to get the desired reference voltage vector Vref in the d-q plane. The objective of space vector PWM technique is to approxim ...
Kirchhoff`s Laws: Voltage and Current in Circuits
Kirchhoff`s Laws: Voltage and Current in Circuits

... to the current leaving that junction. Stated another way: No matter how many paths into and out of a single point, all the current leaving that point must equal the current arriving at that point. This law is sometimes called the junction rule. Kirchhoff ’s Voltage Law: The algebraic sum of the volt ...
SLC-600-1200-1800 230V, 60Hz
SLC-600-1200-1800 230V, 60Hz

... auto-transformer, which provides four levels of line regulation: two boost-stage and one buck-stage. Even when the input voltage varies between 150 – 280V, the output is regulated to within 200 and 250V, well within the range of most equipment. SLc operation is monitored by four status LEDs, indicat ...
Voltage and Current Quiz Key Equations
Voltage and Current Quiz Key Equations

... 5. A current is running through a wire of finite resistance. What must be true about this wire? a) It must be attached to a light bulb b) It must be attached to a battery c) It must have a different voltage on one end than it does on the other d) None of the above ...
Thyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers

... or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 / 110 / 220 / 400 VDC Output current: up to 3250 A Output power: 100 W - 500 kW ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... Most of the world's electric power supply systems are widely interconnected. This is done for economic reasons, to reduce the cost of electricity and to improve reliability of power supply. Transmission interconnections enable taking advantage of diversity of loads, availability of sources, and fuel ...
HU3313501355
HU3313501355

... Considering the structure of six-switch converter, In each leg, there are two modulating waveforms, one for the rectifier side (Vxr) and one for the inverter side (Vxi), The key point in the modulation of the proposed converter is that the interference of the rectifier and inverter reference wavefor ...
thermal arc 400 se
thermal arc 400 se

... The 400SE is a DC microprocessor controlled I.G.B.T. inverter arc welding power source with constant current (CC) output characteristics designed for Stick and Scratch TIG applications. The 400SE operates from 3 phase 250v/400v, 50/60 Hz. The unit comes in a heavy duty tubular protection frame and h ...
Lab8_Introduction
Lab8_Introduction

AQ33247251
AQ33247251

... The impact of Distributed Generation (DG) units on the voltage stability, power quality and reactive power margins have become significant. It is well known fact that Reactive power is very difficult to transport. At high loadings, relative losses of reactive power on transmission lines are often si ...
Voltage Doublers
Voltage Doublers

Up to 16 Circuits! Expanda
Up to 16 Circuits! Expanda

... Pulse input 16.7 ms (When 30 Hz selected), (Min. input signal width) ON : OFF ratio = 1 : 1 Input signal ...
ECE 331:  Electronics Principles I Fall 2013
ECE 331: Electronics Principles I Fall 2013

HMC358MS8G - Hittite Microwave Corporation
HMC358MS8G - Hittite Microwave Corporation

< 1 ... 902 903 904 905 906 907 908 909 910 ... 1089 >

Three-phase electric power



Three-phase electric power is a common method of alternating-current electric power generation, transmission, and distribution. It is a type of polyphase system and is the most common method used by electrical grids worldwide to transfer power. It is also used to power large motors and other heavy loads. A three-phase system is usually more economical than an equivalent single-phase or two-phase system at the same line to ground voltage because it uses less conductor material to transmit electrical power.The three-phase system was independently invented by Galileo Ferraris, Mikhail Dolivo-Dobrovolsky, Jonas Wenström and Nikola Tesla in the late 1880s.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report