• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
P-Q theory based design of Unified Power Quality Conditioner for
P-Q theory based design of Unified Power Quality Conditioner for

... affecting the performance of the equipment connected to the point of common coupling (PCC). Another problem is, it causes voltage unbalance at both ends of PCC thus affecting the operation of other loads connected to it [6]. The solution is Unified Power Quality Conditioner (UPQC) which is an integr ...
The asynchronous machine model
The asynchronous machine model

A Low Noise Amplifier for Phase Noise Measurements
A Low Noise Amplifier for Phase Noise Measurements

... in the presence high level close-in noise. A fairly high frequency high pass response is also useful when observing “jumpy” oscillators on an oscilloscope. A high-pass rolloff at 2.5 Hz is also recommended since many phase noise measurements only extend down to 10 Hz and the high-pass will reduce th ...
AT6731
AT6731

Minimizing the SET-related effects on the output of a voltage linear
Minimizing the SET-related effects on the output of a voltage linear

Power Quality Improvement in PMBLDCM Drive
Power Quality Improvement in PMBLDCM Drive

talk
talk

... [4] ‘A 90-nm CMOS Two-Stage Low-Noise Amplifier for 3-5-GHz Ultra-Wideband Radio’ , Radio Frequency Integrated Circuits Symposium 2008, p489 – 492. ...
Control Strategy for Power Flow Control
Control Strategy for Power Flow Control

07Circuits
07Circuits

Moreover Corcom filters are being tested at 6 times the nominal
Moreover Corcom filters are being tested at 6 times the nominal

... If not explicitly stated in the various data sheets, the max. permissible operating voltage for filters is 250 VAC, 50/60 Hz. Filters can also be used in DC-networks if above stated operating voltages are not exceeded. 7.6 Climate Class All filters are of Climate Class JPF (Ambient Temperature -10° ...
Series and Shunt Compensation
Series and Shunt Compensation

... From a DC input voltage source, provided by the charged capacitor CS, the converter produces a set of controllable three-phase output voltages with the frequency of the ac power system. Each output voltage is in phase with, and coupled to the corresponding ac system voltage via a relatively small (0 ...
dbmb voltage or power?
dbmb voltage or power?

... Consider a sine wave viewed in the time domain – that is, amplitude vs. time – as might be seen on an oscilloscope. This alternating current waveform’s amplitude or level can be characterized in a variety of ways. One can measure the sine wave’s peak-to-peak, peak, root mean square or average values ...
MICRO-TURBINE GENERATOR SYSTEM
MICRO-TURBINE GENERATOR SYSTEM

... combustor where it is mixed with fuel , ignited and burnt. The ignitor is used only during start up and then the flame is selfsustaining. The combusted gas passes through the turbine nozzle and turbine wheel converting the thermal energy of the hot expanding gases to rotating mechanical energy of th ...
B.J. Pierquet and D.J. Perreault, “A Single-Phase Photovoltaic Inverter Topology with a Series-Connected Power Buffer,” IEEE Transactions on Power Electronics , Vol. 28, No. 10, pp. 4603-4611, Oct. 2013.
B.J. Pierquet and D.J. Perreault, “A Single-Phase Photovoltaic Inverter Topology with a Series-Connected Power Buffer,” IEEE Transactions on Power Electronics , Vol. 28, No. 10, pp. 4603-4611, Oct. 2013.

... inverter, transformation stage, energy buffer, and cycloconverter. Each is connected electrically in series, with a common high-frequency resonant current linking them together. At first glance, this series-connected configuration would seem to impose a heavy conduction-loss penalty. However, scalin ...
glossary of technical terms
glossary of technical terms

... an essential protective component integrated in HVDC convertor valves, used to limit the high rise rate of currents and protect against current surges, and to prevent an off-line convertor thyristor from opening in error which can be caused by a voltage surge ...
A Control Strategy for Hybrid Power Filter to Compensate Four
A Control Strategy for Hybrid Power Filter to Compensate Four

... studied topology [6]–[10]. However, the costs of shunt active filters are relatively high for large-scale system and are difficult to use in high-voltage grids. In addition, their compensating performance is better in the harmonic current source load type than in the harmonic voltage source load typ ...
Power quality: Innovation in harmonic filtering
Power quality: Innovation in harmonic filtering

Improving the Power Factor of Isolated Flyback Converters for
Improving the Power Factor of Isolated Flyback Converters for

File
File

... What is the maximum current that it can take each time? There is a difference between the two leads for the current they can take when unwound because the leads are of different thicknesses. Leads have to be thicker to carry larger currents. ...
A simple way to test buck converter stability
A simple way to test buck converter stability

... sufficient driving capability to drive small MOSFETs with fast rise and fall times. The duty-cycle is normally set at a low level, around 5%. This makes it possible to draw larger pulse currents while limiting the total power in the pulse load resistor and MOSFET. A pulse width of around 150µsec is ...
LK3519521955
LK3519521955

... HVDS project is to reconfigure the existing Low voltage (LT) network as High Voltage Distribution System, wherein the 11kV line is taken as near to the loads as possible and the LT power supply is fed by providing appropriate capacity transformer and minimum length of LT line with an objective to pr ...
A new market for residual current protection
A new market for residual current protection

... The whole installation is controlled by progammable logic controllers (PLCs) fed by 110V centre-tapped power supplies. There are four separate panels and each has RCBO protection on both the primary and secondary side of the transformer. At one time such controls would have been supplied by a 110V p ...
Flash Memory - School of Electrical Engineering and Computer
Flash Memory - School of Electrical Engineering and Computer

... NOR Flash Memory: Block read uses constant voltage level. Power management is required only for write and erase operations Each tasks have deadline time This algorithm based on Earliest Deadline First (EDF) algorithm. That is earliest deadline tasks are scheduled very first First K tasks are operate ...
Innovative CPU Power Controller Architecture Enables Significant
Innovative CPU Power Controller Architecture Enables Significant

ppt
ppt

... order of magnitude of the intrinsic asynchronous circuit operating frequency, the adaptive circuit requires less energy, as long as the average voltage required of the adaptive circuit is less than the intrinsic voltage of the asynchronous circuit. ...
< 1 ... 841 842 843 844 845 846 847 848 849 ... 1089 >

Three-phase electric power



Three-phase electric power is a common method of alternating-current electric power generation, transmission, and distribution. It is a type of polyphase system and is the most common method used by electrical grids worldwide to transfer power. It is also used to power large motors and other heavy loads. A three-phase system is usually more economical than an equivalent single-phase or two-phase system at the same line to ground voltage because it uses less conductor material to transmit electrical power.The three-phase system was independently invented by Galileo Ferraris, Mikhail Dolivo-Dobrovolsky, Jonas Wenström and Nikola Tesla in the late 1880s.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report