• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Document
Document

... it must be recognized that DCM occurs for low values of inductor currents. For regulated output applications, this condition is associated with large resistance (low current) loading, and/or high input voltages. Inductor values should be chosen accordingly, with appropriate safety factors. ...
A Simplified Active Input EMI Filter of Common-mode Voltage Cancellation
A Simplified Active Input EMI Filter of Common-mode Voltage Cancellation

... *Research Center for Communications and Information Technology, Faculty of Engineering, King Mongkut’s Institute of Technology Ladkrabang, Bangkok, Thailand. ** Faculty of Engineering, Srinakharinwirot University, Ongkharak, Thailand. ***Department of Electrical and Electric Engineer, Tokai Universi ...
CAT IV or CAT III?
CAT IV or CAT III?

... environment the overvoltages can be high, dangerous and unpredictable. The users often wear the instrument around the neck or in the hands during the measurements. This is a very inconvenient situation if a breakdown occurs. When a breakdown takes place, a lot of energy is concentrated on the instru ...
POWER PROTECTION
POWER PROTECTION

... year. However, potentially dangerous power fluctuations occur at an average rate of nearly one a day. If you need a UPS and especially power conditioning - consider the PowerSure InterActive from Liebert. Designed with simple controls for easy operation, the PowerSure InterActive provides five minut ...
NIH PROJECT
NIH PROJECT

... Higher Energy density Higher voltage Long operating time Compact ...
AN-781 APPLICATION NOTE
AN-781 APPLICATION NOTE

... The VX1 to VX4 pins are dual-purpose pins. They can be configured as normal voltage monitors. In this instance they have a single programmable range of 0.573 V to 1.375 V (which is identical to the lowest range on the VP1 to VP4 pins). They can also be set up as digital input pins, looking for logic ...
Gain Block Active Bias Circuit AN035
Gain Block Active Bias Circuit AN035

halaman pengesahan - (COT) Publications
halaman pengesahan - (COT) Publications

electric circuit
electric circuit

Mar 2008 - Tiny, Fast and Efficient Comparator Regenerates Clock Signals up to 3MHz
Mar 2008 - Tiny, Fast and Efficient Comparator Regenerates Clock Signals up to 3MHz

... The LTC6702’s push-pull output stage and its ability to operate with either input above the positive supply rail simplifies logic level translation. Many comparators use an open collector or open drain type output stage to enable ...
Node-Voltage Analysis
Node-Voltage Analysis

Quality Control Parameters
Quality Control Parameters

... Inside shipping box, no extra ground shields. AL foil in box connected to tube ground. Our standard ZEUS gas mixture is used. Conditioning phase: Ramp up HV from 1000V in 100 V increments while monitoring the tube current. If the current remains below xxx nA after yyy minutes the voltage is increase ...
A Home Appliance Recognition System Using the Approach of
A Home Appliance Recognition System Using the Approach of

... but also the apparent power steps. It allows the microcontroller to calculate the power factor and then use it together with the active power step as a load signature. For example, if in a given house there are 30 lamps of 15 watts distributed in 10 rooms (10 different circuits) the identification s ...
Fluke 1760 - Access Frontier
Fluke 1760 - Access Frontier

... single- and three-phase electrical measurements, like rms voltage and current were defined long ago, many power quality parameters were not previously defined, forcing manufacturers to develop their own algorithms. With so much variation between instruments, electricians tend to waste too much time ...
Coordinated voltage control of a decoupled three
Coordinated voltage control of a decoupled three

lab sheet - Faculty of Engineering
lab sheet - Faculty of Engineering

... transmission lines of 115 kV and higher are caused by lightning, which results in the flashover of insulators. The high voltage between a conductor and the grounded supporting tower causes ionization, which provides a path to ground for the charge induced by the lightning stroke. Once the ionized pa ...
BUL38D
BUL38D

... speeds and high voltage capability. The device is designed for use in electronic transformer for halogen lamps. ...
AN-8024 Applying Fairchild Power Switch (FPS ) FSBH-series to Standby Auxiliary Power Supply
AN-8024 Applying Fairchild Power Switch (FPS ) FSBH-series to Standby Auxiliary Power Supply

... As can be seen in Equation (5), the voltage stress across MOSFET can be reduced by reducing VRO. This, however, increases the voltage stresses on the rectifier diodes in the secondary side, as shown in Equation (6). Therefore, VRO should be determined by a trade-off between the voltage stresses of M ...
High-Efficiency AC Power Distribution for Data Centers
High-Efficiency AC Power Distribution for Data Centers

Large-Current Driving Applications
Large-Current Driving Applications

DATASHEET: Furman AR-PRO
DATASHEET: Furman AR-PRO

... configuration, accidental connection to 220V occurs surprisingly often). This feature also makes the AR-PRO ideal as a component of a power distribution scheme suitable for worldwide use, accommodating national voltages of 100, 120, 220, 240, or others with equal ease and without need for readjustme ...
Part 4 - iaria
Part 4 - iaria

... Type I Voltage Dips: – Drop in voltage is mainly in one phase-to-neutral voltage – V is the characteristic residual voltage or magnitude of the L-N dip. E is the nominal voltage ...
Control of DFIG-WT under unbalanced grid voltage conditions
Control of DFIG-WT under unbalanced grid voltage conditions

TEST FOR INTRODUCTION TO ELECTRICITY
TEST FOR INTRODUCTION TO ELECTRICITY

DN182 - The LT1167: Single Resistor Sets the Gain of the Best Instrumentation Amplifier
DN182 - The LT1167: Single Resistor Sets the Gain of the Best Instrumentation Amplifier

... of 1 to 100, gain error is less than 0.05%, making the gainset resistor tolerance the dominant source of gain error. The LT1167’s gain nonlinearity is unsurpassed when compared to other monolithic solutions. It is specified at less than 40ppm when operating at a gain of 1000 while driving a 2kΩ load ...
< 1 ... 746 747 748 749 750 751 752 753 754 ... 1089 >

Three-phase electric power



Three-phase electric power is a common method of alternating-current electric power generation, transmission, and distribution. It is a type of polyphase system and is the most common method used by electrical grids worldwide to transfer power. It is also used to power large motors and other heavy loads. A three-phase system is usually more economical than an equivalent single-phase or two-phase system at the same line to ground voltage because it uses less conductor material to transmit electrical power.The three-phase system was independently invented by Galileo Ferraris, Mikhail Dolivo-Dobrovolsky, Jonas Wenström and Nikola Tesla in the late 1880s.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report