• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
DESCRIPTION OF SUPER SWITCH OPERATION The Super switch
DESCRIPTION OF SUPER SWITCH OPERATION The Super switch

... designed to transfer the output load to the other “alternate” input source, as long as the alternate source is within acceptable voltage limits and is synchronized with the preferred source within the selected phase synchronization window. The Superswitch provides fast, break-before-make transfers t ...
A Forward-Body-Bias Tuned 450MHz Gm-C 3rd-Order Low
A Forward-Body-Bias Tuned 450MHz Gm-C 3rd-Order Low

AN-1885 LM22670 Evaluation Board (Rev. D)
AN-1885 LM22670 Evaluation Board (Rev. D)

... TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide adequate design and operating safeguar ...
G032 - Pulse Electronics
G032 - Pulse Electronics

... • Not influenced by external magnetic fields, and can be immune to magnetic tampering • Are non-intrusive – draws no power from the main circuit • Have a very wide Sensing bandwidth extending from 0.1 Hz up to 17 MHz • Measures AC signals superimposed on a large DC Current • Can measure large curren ...
SECTION 16403
SECTION 16403

AP3983E - Diodes Incorporated
AP3983E - Diodes Incorporated

... Operation Description (Cont.) ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

Model 12701 PEAK VOLTAGE CALIBRATOR OPERATING MANUAL
Model 12701 PEAK VOLTAGE CALIBRATOR OPERATING MANUAL

... the starting voltage and the breaking voltage must be understood. Starting Voltage is the potential required to cause a spark initially to jump between an electrode and a metal object. This voltage is usually higher than the voltage required to sustain the spark once it has started. Breaking Voltage ...
Unit 74: Aircraft Electrical Devices and Circuits - Edexcel
Unit 74: Aircraft Electrical Devices and Circuits - Edexcel

... The unit could be delivered through a combination of theory lessons and demonstrations, reinforced through practical work in an electrical workshop or laboratory. It is important that learners have a thorough understanding of circuit theory if they are to be able to understand the operation of compl ...
Current & Voltage in Circuits
Current & Voltage in Circuits

... When components are connected in parallel to each other voltage they will each have the same _________. parallel Lamps are usually connected in __________ to each other as switches this allows them to be controlled individually by _________ blows the others can still continue to and if one lamp ____ ...
Enhancement of Power Quality on Wind Generation Systems by
Enhancement of Power Quality on Wind Generation Systems by

... durations of 0.5 cycles to 1.0 minute. Voltage sags are usually associated with system faults but can also be caused by switching of heavy loads or starting of large motors. A voltage sag lasting for 0.2 s is applied at t=0.3 s at the grid side of the system under study. Without the compensating uni ...
DC Motor Characteristics
DC Motor Characteristics

... independent of velocity, but that the sign of Dc changes withϖ. As the velocity increases, viscous drag increases the mechanical loss due to friction. Examples of viscous drag include lubrication in the bearings and aerodynamic drag caused by the load moving in ...
3A1637
3A1637

... Mounting: The SPD should be installed as close as possible to the device it is protecting. Good installation practice is to keep conductor length as short and straight as possible. The SPDs mount on a 35mm DIN-rail that should be securely mounted to the back of the panel’s interior using ¼ inch bolt ...
MAX258 500mA, Push-Pull Transformer Driver for Isolated Power
MAX258 500mA, Push-Pull Transformer Driver for Isolated Power

... Transformer selection for the MAX258 can be simplified by the use of the ET product. The ET product relates the maximum allowable magnetic flux density in a transformer core to the voltage across a winding and switching period. Inductor magnetizing current in the primary winding changes linearly wit ...
ICS844021-01 - Integrated Device Technology
ICS844021-01 - Integrated Device Technology

... pin and also shows that VDDA requires that an additional10Ω resistor along with a 10µF bypass capacitor be connected to the VDDA pin. ...
Introduction, Features and Applications
Introduction, Features and Applications

... For a given motor, higher driver current will make the motor to output more torque, but at the same time causes more heating in the motor and driver. Therefore, output current is generally set to be such that the motor will not overheat for long time operation. Since parallel and serial connections ...
File
File

... Digital Multimeter Introduction • Choosing the right meter Category 1. With the likely hood of working in multiple different category environments always choose a meter that will be safe for working on the HIGHEST category that could potentially be accessed 2. Choose a Steady State Voltage rating t ...
HS-100 is a low voltage card key switch
HS-100 is a low voltage card key switch

... The HS-100 is a low voltage card key switch that enables or disables power to electric circuits and loads in a hotel guest room or similar site. When a hotel door entry card key (or the key fob HS-FOB) is inserted in the HS-100 card slot the controlled circuits are energized. When the hotel door ent ...
Model 548 Solid State DC Load Switch
Model 548 Solid State DC Load Switch

optimal location of voltage regulators in radial distribution
optimal location of voltage regulators in radial distribution

... analytical tools such as optimal power flow, voltage stability, failure indicators analysis etc, and by the installation of devices such as fixed and controlled capacitors banks, automatic voltage regulators and transformers with on-load tap changers, [2]-[3]. The use of new devices is constrained b ...
ATLAS-CMS Electronics Workshop
ATLAS-CMS Electronics Workshop

... and/or Q0 doublet; attractive if total beam current is limited; transformed to a 50-ns spacing by keeping only 1/2 the number of bunches • 50-ns option: has fewer longer bunches of higher charge ; can be realized with NbTi technology if needed ; compatible with LHCb ; open issues are SPS & beam-beam ...
Aalborg Universitet
Aalborg Universitet

... Vasquez; Guerrero, Josep M. Published in: Proceedings of the 11th International Multi-Conference on Systems, Signals and Devices, SSD 2014 DOI (link to publication from Publisher): ...
AE04603181184
AE04603181184

... non-critical path until positive slack disappears. This to build the CVS structure. Finally, the simulator calculates the final result. Power of the CVS structure and compares it with the power of the replacement proceeds in reverse order from the end of each path 0) initial single-VDD design. The i ...
Electricity generators
Electricity generators

... windings set in longitudinal slits in the armature core and connected to appropriate segments of a multiple commutator. In an armature having only one loop of wire, the current produced will rise and fall depending on the part of the magnetic field through which the loop is moving. A commutator of m ...
emergency power – storage batteries
emergency power – storage batteries

... of power. Note that this type of regulation has a finite response time and does not handle pulsating loads well. DC Inverter – This type of generator supplies DC current that is then converted to 60 Hz 120 VAC power by an electronic inverter. The motor speed can vary with load and can respond more q ...
< 1 ... 671 672 673 674 675 676 677 678 679 ... 1089 >

Three-phase electric power



Three-phase electric power is a common method of alternating-current electric power generation, transmission, and distribution. It is a type of polyphase system and is the most common method used by electrical grids worldwide to transfer power. It is also used to power large motors and other heavy loads. A three-phase system is usually more economical than an equivalent single-phase or two-phase system at the same line to ground voltage because it uses less conductor material to transmit electrical power.The three-phase system was independently invented by Galileo Ferraris, Mikhail Dolivo-Dobrovolsky, Jonas Wenström and Nikola Tesla in the late 1880s.