www.BDTIC.com/FAIRCHILD 1V5KE6V8(C)A - 1V5KE440(C)A 1500 W Transient Voltage Suppressors 1V5KE6V8(C)A - 1V5KE440(C)A —
... Distributors who are listed by country on our web page cited above. Products customers buy either from Fairchild directly or from Authorized Fairchild Distributors are genuine parts, have full traceability, meet Fairchild's quality standards for handling and storage and provide access to Fairchild's ...
... Distributors who are listed by country on our web page cited above. Products customers buy either from Fairchild directly or from Authorized Fairchild Distributors are genuine parts, have full traceability, meet Fairchild's quality standards for handling and storage and provide access to Fairchild's ...
AP2161/ AP2171 Description Pin Assignments
... Three possible overload conditions can occur. In the first condition, the output has been shorted to GND before the device is enabled or before VIN has been applied. The AP2161/AP2171 senses the short circuit and immediately clamps output current to a certain safe level namely ILIMIT. In the second ...
... Three possible overload conditions can occur. In the first condition, the output has been shorted to GND before the device is enabled or before VIN has been applied. The AP2161/AP2171 senses the short circuit and immediately clamps output current to a certain safe level namely ILIMIT. In the second ...
Datasheet
... Recommended operating conditions; voltages are referenced to GND (ground = 0 V). Tamb = −40 °C to +85 °C ...
... Recommended operating conditions; voltages are referenced to GND (ground = 0 V). Tamb = −40 °C to +85 °C ...
Overview of Silicon Carbide Power Devices
... polytypes. Depending on the polytype crystal structure, the energy gap of silicon carbide varies from 2.2 to 3.3 eV. Among them, 4H and 6H are of interest technologically since large wafers can be made in this material, and hence used for device production. Table I summarizes the characteristics of ...
... polytypes. Depending on the polytype crystal structure, the energy gap of silicon carbide varies from 2.2 to 3.3 eV. Among them, 4H and 6H are of interest technologically since large wafers can be made in this material, and hence used for device production. Table I summarizes the characteristics of ...
Folie 1 - RWTH Aachen University
... If one converter is employed per module, individual modules can be powered on/off In a scenario with one charge pump employed per chip, individual chips can be powered on/off Note: with SP, the whole chain is powered on at once from a constant current source PS. If a module needs to be bypassed, ...
... If one converter is employed per module, individual modules can be powered on/off In a scenario with one charge pump employed per chip, individual chips can be powered on/off Note: with SP, the whole chain is powered on at once from a constant current source PS. If a module needs to be bypassed, ...
SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC
... D. Internal Connections – No plug-in component modules or printed circuit boards shall be used as surge current conductors. All internal components shall be soldered, hardwired with connections utilizing low impedance conductors. E. Monitoring Diagnostics – Each SPD shall provide the following integ ...
... D. Internal Connections – No plug-in component modules or printed circuit boards shall be used as surge current conductors. All internal components shall be soldered, hardwired with connections utilizing low impedance conductors. E. Monitoring Diagnostics – Each SPD shall provide the following integ ...
Folie 1 - RWTH Aachen University
... Multiplicity (modules per cable) as today or higher Open connections (e.g. at PP1) lead to loss of power group Short on module leads to loss of power group Protection needed? Use DC-DC converter to switch off module? ...
... Multiplicity (modules per cable) as today or higher Open connections (e.g. at PP1) lead to loss of power group Short on module leads to loss of power group Protection needed? Use DC-DC converter to switch off module? ...
mc-4210 - h2s modbus addressable sensor
... 4) DS6 is hardwired for Voltage Mode. (DS1-4) Selects sensor full scale range. OFF = 100 PPM, ON = 200 PPM. (DS1-5) Selects sensor calibration gas value. OFF = 100 PPM, ON = 200 PPM. (DS1-6) Enables the sensor setup mode to allow setting the warn and alarm levels using the setup potentiometer (R15). ...
... 4) DS6 is hardwired for Voltage Mode. (DS1-4) Selects sensor full scale range. OFF = 100 PPM, ON = 200 PPM. (DS1-5) Selects sensor calibration gas value. OFF = 100 PPM, ON = 200 PPM. (DS1-6) Enables the sensor setup mode to allow setting the warn and alarm levels using the setup potentiometer (R15). ...
Contents - Center for Occupational Research and Development
... Demonstrate the use of tools, fasteners, and equipment. Demonstrate and explain the use of threaded fasteners. Demonstrate and explain the use of nonthreaded fasteners. Demonstrate and explain the use and types of anchors. Install fasteners and anchors. Demonstrate safe operation of power and powder ...
... Demonstrate the use of tools, fasteners, and equipment. Demonstrate and explain the use of threaded fasteners. Demonstrate and explain the use of nonthreaded fasteners. Demonstrate and explain the use and types of anchors. Install fasteners and anchors. Demonstrate safe operation of power and powder ...
Appendix B: renewable resource Injection Capability at LIPA
... The Long Island Lighting Company d/b/a LIPA (“LIPA” or “Company”), a corporation organized and existing under the laws of the State of New York and a wholly owned subsidiary of the Long Island Power Authority, is a corporate municipal instrumentality and political subdivision of the State of New Yor ...
... The Long Island Lighting Company d/b/a LIPA (“LIPA” or “Company”), a corporation organized and existing under the laws of the State of New York and a wholly owned subsidiary of the Long Island Power Authority, is a corporate municipal instrumentality and political subdivision of the State of New Yor ...
2011 Protection Design Guide for Portable Device
... This is especially critical in the case of fast rise-time transients such as ESD or EFT. Recall that the voltage developed across an inductive load is proportional to the time rate of change in current (V = L di/dt). An ESD induced transient reaches a peak in less than 1ns (per IEC 61000-4-2). Assum ...
... This is especially critical in the case of fast rise-time transients such as ESD or EFT. Recall that the voltage developed across an inductive load is proportional to the time rate of change in current (V = L di/dt). An ESD induced transient reaches a peak in less than 1ns (per IEC 61000-4-2). Assum ...
DC Grids for Wind Farms
... a high voltage direct current connection (HVDC) and by using a local DC-grid in the wind farm. New semiconductor technologies make this possible but suitable converter topologies have not been established yet. A DC/DC converter can be described as the DC equivalent of an AC transformer. It changes t ...
... a high voltage direct current connection (HVDC) and by using a local DC-grid in the wind farm. New semiconductor technologies make this possible but suitable converter topologies have not been established yet. A DC/DC converter can be described as the DC equivalent of an AC transformer. It changes t ...
22 & 33 kV CURRENT & POTENTIAL TRANSFORMERS
... of this specification, ratio changing arrangement shall be provided on secondary winding for multi-ratio design, either a number of identical secondary winding may be provided to achieve desired ratios by series, parallel connection for the secondary winding or the secondary winding may be tapped. H ...
... of this specification, ratio changing arrangement shall be provided on secondary winding for multi-ratio design, either a number of identical secondary winding may be provided to achieve desired ratios by series, parallel connection for the secondary winding or the secondary winding may be tapped. H ...
64
... used to transmit angular data electrically from one location the line signals. This demands an evaluation of an integral of to another, where a high degree of accuracy is required. the squared error over number of periods of the resolver They are also used in many safety critical systems like output ...
... used to transmit angular data electrically from one location the line signals. This demands an evaluation of an integral of to another, where a high degree of accuracy is required. the squared error over number of periods of the resolver They are also used in many safety critical systems like output ...
AP7217
... A 1μF ceramic capacitor is recommended to connect between IN and GND pins to decouple input power supply glitch and noise. The amount of the capacitance may be increased without limit. A lower ESR (Equivalent Series Resistance) capacitor allows the use of less capacitance, while higher ESR type requ ...
... A 1μF ceramic capacitor is recommended to connect between IN and GND pins to decouple input power supply glitch and noise. The amount of the capacitance may be increased without limit. A lower ESR (Equivalent Series Resistance) capacitor allows the use of less capacitance, while higher ESR type requ ...
"Supply-Voltage Supervisors"
... those mandated by government requirements. Customers are responsible for their applications using TI components. In order to minimize risks associated with the customer’s applications, adequate design and operating safeguards must be provided by the customer to minimize inherent or procedural hazard ...
... those mandated by government requirements. Customers are responsible for their applications using TI components. In order to minimize risks associated with the customer’s applications, adequate design and operating safeguards must be provided by the customer to minimize inherent or procedural hazard ...
Three-phase electric power
Three-phase electric power is a common method of alternating-current electric power generation, transmission, and distribution. It is a type of polyphase system and is the most common method used by electrical grids worldwide to transfer power. It is also used to power large motors and other heavy loads. A three-phase system is usually more economical than an equivalent single-phase or two-phase system at the same line to ground voltage because it uses less conductor material to transmit electrical power.The three-phase system was independently invented by Galileo Ferraris, Mikhail Dolivo-Dobrovolsky, Jonas Wenström and Nikola Tesla in the late 1880s.