Switched-mode power supply
... A linear regulator provides the desired output voltage by dissipating excess power in ohmic losses (e.g., in a resistor or in the collector–emitter region of a pass transistor in its active mode). A linear regulator regulates either output voltage or current by dissipating the excess electric power ...
... A linear regulator provides the desired output voltage by dissipating excess power in ohmic losses (e.g., in a resistor or in the collector–emitter region of a pass transistor in its active mode). A linear regulator regulates either output voltage or current by dissipating the excess electric power ...
Electric Furnace
... An important aspect of non-ferrous metal production is the separation process known as smelting, in which the concentrated ore is melted and separated into two components of different densities: the slag and the matte, the latter usually being the product. The smelting process is carried out through ...
... An important aspect of non-ferrous metal production is the separation process known as smelting, in which the concentrated ore is melted and separated into two components of different densities: the slag and the matte, the latter usually being the product. The smelting process is carried out through ...
Bip TR 160V, 0.7A VCE(sat); 0.5V max. PNP Single NMP
... system, safety equipment etc.) that shall require extremely high level of reliability and can directly threaten human lives in case of failure or malfunction of the product or may cause harm to human bodies, nor shall they grant any guarantee thereof. If you should intend to use our products for new ...
... system, safety equipment etc.) that shall require extremely high level of reliability and can directly threaten human lives in case of failure or malfunction of the product or may cause harm to human bodies, nor shall they grant any guarantee thereof. If you should intend to use our products for new ...
Introduction to PSpice
... IPROBE The IPROBE and VIEWPOINT parts can be used to display the results of the Nodal Analysis On The Schematic. Or you can click the V and I button to display the voltage and current. ...
... IPROBE The IPROBE and VIEWPOINT parts can be used to display the results of the Nodal Analysis On The Schematic. Or you can click the V and I button to display the voltage and current. ...
PowerPoint
... Electrical power is work being done by current(amperage) under pressure(voltage) in getting the electrons through the resistance of wires and machines back to the generator. Units of 1,000 watts are called kilowatts. The relationship between watts(P), amps(I), and volts(E) is P=I x E. ...
... Electrical power is work being done by current(amperage) under pressure(voltage) in getting the electrons through the resistance of wires and machines back to the generator. Units of 1,000 watts are called kilowatts. The relationship between watts(P), amps(I), and volts(E) is P=I x E. ...
PowerEase® 90W Power Supply_RevB.0
... General safety ............................................................................................................................................................... 10 Instrument safety ........................................................................................................ ...
... General safety ............................................................................................................................................................... 10 Instrument safety ........................................................................................................ ...
S280-77-5
... Each control is completely assembled, inspected, and tested at the factory. It is in good condition when accepted by the carrier for shipment. ...
... Each control is completely assembled, inspected, and tested at the factory. It is in good condition when accepted by the carrier for shipment. ...
your New Radio
... MMICs are designed to work is 50 ohms. The typical noise figure of a monolithic microwave integrated circuit (MMIC) amplifier is approximately 3.5 to 6 dB. ...
... MMICs are designed to work is 50 ohms. The typical noise figure of a monolithic microwave integrated circuit (MMIC) amplifier is approximately 3.5 to 6 dB. ...
chapter 6
... the voltage on no load will be the maximum a.c. voltage. But when on load, the condenser gets charged from the supply voltage and discharges into load resistance RL whenever the supply voltage waveform varies from peak value zero value. These waveforms are shown in Fig. 6.2. When loaded, a fluctuati ...
... the voltage on no load will be the maximum a.c. voltage. But when on load, the condenser gets charged from the supply voltage and discharges into load resistance RL whenever the supply voltage waveform varies from peak value zero value. These waveforms are shown in Fig. 6.2. When loaded, a fluctuati ...
A Soft-Switching DC/DC Converter with High Voltage Gain
... Fig.1.Circuit diagram of the proposed dc/dc converter. In applications that require a voltage step-up function and a continuous input current, a continuous-conductionmode (CCM) boost converter is often used due to its advantages such as continuous input current and simple structure. However, it has ...
... Fig.1.Circuit diagram of the proposed dc/dc converter. In applications that require a voltage step-up function and a continuous input current, a continuous-conductionmode (CCM) boost converter is often used due to its advantages such as continuous input current and simple structure. However, it has ...
DC-DC converter control circuits
... The following power supply characteristics must be chosen: VIN = Nominal input voltage VOUT = Desired output voltage, |VOUT| = 1.25 (1 + R2/R1) IOUT = Desired output current fMIN = Minimum desired output switching frequency at the selected values of VIN and IO VRIPPLE = Desired peak to peak output r ...
... The following power supply characteristics must be chosen: VIN = Nominal input voltage VOUT = Desired output voltage, |VOUT| = 1.25 (1 + R2/R1) IOUT = Desired output current fMIN = Minimum desired output switching frequency at the selected values of VIN and IO VRIPPLE = Desired peak to peak output r ...
No Slide Title
... unique feature of its ability to “learn” individual motor parameters, giving it the flexibility to adapt to each application by “learning” values of motor inrush current, negative sequence current K factor, cool down rates, start thermal capacity and acceleration time. ...
... unique feature of its ability to “learn” individual motor parameters, giving it the flexibility to adapt to each application by “learning” values of motor inrush current, negative sequence current K factor, cool down rates, start thermal capacity and acceleration time. ...
Redalyc.Improved Energy Conversion Process With Coupling
... This paper assesses Voltage unbalance study as one of power quality issues which is especially effected distribution voltages and is noteworthy. however it is possible that voltage in level of producing and transmission be balanced but this voltages in level of distribution can go out of balance and ...
... This paper assesses Voltage unbalance study as one of power quality issues which is especially effected distribution voltages and is noteworthy. however it is possible that voltage in level of producing and transmission be balanced but this voltages in level of distribution can go out of balance and ...
MAX2750/MAX2751/MAX2752 2.4GHz Monolithic Voltage-Controlled Oscillators General Description
... 50Ω including an on-chip DC blocking capacitor. No external DC blocking capacitor is required, eliminating the need for any external components. The output amplifier has its own VCC and GND pins to minimize load-pulling effects. The amplifier boosts the oscillator signal to a level suitable for driv ...
... 50Ω including an on-chip DC blocking capacitor. No external DC blocking capacitor is required, eliminating the need for any external components. The output amplifier has its own VCC and GND pins to minimize load-pulling effects. The amplifier boosts the oscillator signal to a level suitable for driv ...
ZLDO330 • 3.3 VOLT ULTRA LOW DROPOUT REGULATOR
... switch mode converters is that only one output can be used in the feedback control loop of the switching regulator. Thus only one output is fully regulated. All other outputs are prone to tracking errors that occur if the load on any output changes significantly. By ensuring close coupling of all tr ...
... switch mode converters is that only one output can be used in the feedback control loop of the switching regulator. Thus only one output is fully regulated. All other outputs are prone to tracking errors that occur if the load on any output changes significantly. By ensuring close coupling of all tr ...
LIEBERT TRANSIENT VOLTAGE SURGE SUPPRESSOR
... All electrical circuits to the SPD must include an equipmentgrounding conductor as required by the NEC and local codes. An insulated grounding conductor is required in addition to any metallic raceway, which may be used as a grounding conductor. For parallel-connected SPDs, the grounding conductor s ...
... All electrical circuits to the SPD must include an equipmentgrounding conductor as required by the NEC and local codes. An insulated grounding conductor is required in addition to any metallic raceway, which may be used as a grounding conductor. For parallel-connected SPDs, the grounding conductor s ...
3 - web page for staff
... The most popular transmission line since it can be fabricated using printed circuit techniques and it is convenient to connect lumped elements and transistor devices. By definition, it is a transmission line that consists of a strip conductor and a grounded plane separated by a dielectric medium ...
... The most popular transmission line since it can be fabricated using printed circuit techniques and it is convenient to connect lumped elements and transistor devices. By definition, it is a transmission line that consists of a strip conductor and a grounded plane separated by a dielectric medium ...
Power module PM-E DC24V (6ES7138-4CA01-0AA0)
... image (PII). This is updated irrespective of whether the "No Load Voltage" diagnosis has been enabled. ● The PM-E DC24V power module is suitable for fail-safe modules. ● Extended temperature range from 0 to 55°C with vertical installation. CAUTION Only connect the specified rated load voltage of 24 ...
... image (PII). This is updated irrespective of whether the "No Load Voltage" diagnosis has been enabled. ● The PM-E DC24V power module is suitable for fail-safe modules. ● Extended temperature range from 0 to 55°C with vertical installation. CAUTION Only connect the specified rated load voltage of 24 ...
Ignitron Driver Manual - Wide Bandwidth High Voltage Probes
... power line you plan to use. If the internal power switch is not set correctly the unit may fail. The factory setting is always for 220 VAC. Connect the input power (220 VAC nominal or 110 VAC nominal) to the AC receptacle once the settings of both switches are assured. If a powered trigger module ha ...
... power line you plan to use. If the internal power switch is not set correctly the unit may fail. The factory setting is always for 220 VAC. Connect the input power (220 VAC nominal or 110 VAC nominal) to the AC receptacle once the settings of both switches are assured. If a powered trigger module ha ...
Three-phase electric power
Three-phase electric power is a common method of alternating-current electric power generation, transmission, and distribution. It is a type of polyphase system and is the most common method used by electrical grids worldwide to transfer power. It is also used to power large motors and other heavy loads. A three-phase system is usually more economical than an equivalent single-phase or two-phase system at the same line to ground voltage because it uses less conductor material to transmit electrical power.The three-phase system was independently invented by Galileo Ferraris, Mikhail Dolivo-Dobrovolsky, Jonas Wenström and Nikola Tesla in the late 1880s.