• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Dynamic Characteristics of Mho Distance Relays
Dynamic Characteristics of Mho Distance Relays

RESET MAX8530/MAX8531 Dual Low-Dropout Linear Regulators with
RESET MAX8530/MAX8531 Dual Low-Dropout Linear Regulators with

... designed primarily for battery-powered applications. For preset output voltages, refer to the Output Voltage Selector Guide. Other combinations between 1.5V and 3.3V are available in 50mV increments. This device supplies loads up to 200mA for OUT1 and 150mA for OUT2. The MAX8530/MAX8531 consist of a ...
ADP1864 数据手册DataSheet 下载
ADP1864 数据手册DataSheet 下载

... capacitor. Pulling the COMP pin below 0.3 V disables the ADP1864 and turns off the external PFET. Analog Ground. Directly connect the compensation and feedback networks to GND, preferably with a small analog GND plane. Connect GND to the power ground (PGND) plane with a narrow track at a single poin ...
SURGE PROTECTION 101 : AN INTRODUCTORY BRIEFING
SURGE PROTECTION 101 : AN INTRODUCTORY BRIEFING

DC2431A - Linear Technology
DC2431A - Linear Technology

... The PGOOD status flag indicates when output voltage is within ±10% of final regulation voltage. The LT8390’s proprietary peak current mode buck-boost architecture ensures DC2431A runs either in discontinuous conduction mode (DCM) or pulse-skipping mode (PSM) without reversed inductor current. Both o ...
Commercial Spa Blower Selection Guide
Commercial Spa Blower Selection Guide

... spas and hot tubs Most spas and hot tubs require regenerative blowers to provide the pressure and flow needed to agitate the water. Sizing a blower can be as simple as following these steps: 1. Determine the number of jets and/or orifices in the spa. 2. Calculate the total area of all the orifices ...
Fast Flashover Identification Methodology on Brushed DC
Fast Flashover Identification Methodology on Brushed DC

... methodology is necessary to ensure the proper commutation process and augmented equipment performance. Commutation in DC machines is a rather difficult process, which can be accompanied, under certain conditions, by sparks and flashovers. Those problems may arise from mechanical issues, such as vibr ...
ICL7652 Advanced LinCMOSTM PRECISION
ICL7652 Advanced LinCMOSTM PRECISION

... The ICL7652 inputs and output are designed to withstand -1 OO-mA surge currents without sustaining latchup. However, because CMOS devices are susceptible to latchup due to their inherent parasitic thyristors, techniques to reduce the chance of latchup should be used whenever possible. Internal prote ...
MPA-460 ANF3/8031 BRUSHLESS SERVO AMPLIFIER
MPA-460 ANF3/8031 BRUSHLESS SERVO AMPLIFIER

Medium Voltage Isolated Phase Bus Guide
Medium Voltage Isolated Phase Bus Guide

... currents and remain functional after short-circuit has been experienced. ...
ADN4664 数据手册DataSheet 下载
ADN4664 数据手册DataSheet 下载

... a terminating resistor, RT. This resistor is chosen to match the characteristic impedance of the medium, typically around 100 Ω. The differential voltage is detected by the receiver and ...
SEL-710 Motor Protection Relay
SEL-710 Motor Protection Relay

No Watt Left Behind
No Watt Left Behind

... detailed submetering information for different loads on different breakers or clusters of breakers and controls. New utility meters will need to communicate bidirectionally, and may need to compute parameters of power flow not commonly assessed by most current meters. The U.S. Department of Energy h ...
BD8303MUV
BD8303MUV

... Since DC/DC converter application is sampled according to the switching frequency, the GBW of the whole system (frequency at which gain is 0 dB) must be set to be equal to or lower than 1/5 of the switching frequency. In summary, target property of applications is as follows: - Phase delay must be 1 ...
A Least-Voltage Drop High Output Resistance Current Source for
A Least-Voltage Drop High Output Resistance Current Source for

... should either generate or block an action potential. After a short inter-pulse interval ti, the second pulse is injected for which Q2 = I stim ⋅ ta . If Q1 = −Q2 , charge cancellation is assured. Therefore in this case the amount of charge can be easily controlled by the pulse duration. In Fig. 1c t ...
EE20 RC_RJIT Conference
EE20 RC_RJIT Conference

... widely applicable in large number of applications. This paper proposed a new multilevel inverter structure with low output harmonics. In this paper the number of switching device is less as compare to the conventional multilevel inverter. It consists of an H-bridge inverter which produces multilevel ...
a review approach of power grid analysis in vlsi designs
a review approach of power grid analysis in vlsi designs

customer service standards for connection
customer service standards for connection

... Customers should notify Endeavour Energy of their supply requirements so that appropriated arrangements can be made. This particularly applies where a customer intends to install items of equipment which:  Place large electrical loads on the electrical distribution system; or  May affect the quali ...
Multimeter and Resistance Lab 1 Materials Identifying Resistors and
Multimeter and Resistance Lab 1 Materials Identifying Resistors and

... Remember it is important to always have some resistance in series with your meter. To protect the current ranges, your meter has a small fuse. If you touch your probes to a voltage source (such as the power jack terminals), you will blow the fuse. This can be replaced easily but is some fuss. If you ...
FEATURES GENERAL DESCRIPTION ADP5034 e ADP5034. T
FEATURES GENERAL DESCRIPTION ADP5034 e ADP5034. T

... Measure the input and output voltages with voltmeters. Make sure that the voltmeters are connected to the appropriate evaluation board terminals and not to the load or power sources themselves. If the voltmeters are not connected directly to the evaluation board, the measured voltages will be incorr ...
summary of requirements
summary of requirements

... Branch circuit protection for motor groups: The revised 31.4.1 may require modification of the ampere rating of the motor group branch circuit protection, or the ampacity of tap (power circuit) conductors, or both. Only branch circuit type fuses and inverse- time circuit breakers are suitable as the ...
Zeng-etal-IEEE-TOIE-2015-Analysis-and-control-of
Zeng-etal-IEEE-TOIE-2015-Analysis-and-control-of

... double-frequency rotational frame [15], a series of resonant controllers tuned at even-order harmonic frequencies [16], or a repetitive controller [17-18]. The energy-based modeling control is based on the schemes of regulating the total energy and energy balancing [19-23]. Although extensive work o ...
Choosing the Right Inductor and Capacitor for
Choosing the Right Inductor and Capacitor for

... the efficiency of the dc/dc converters used in these products. Efficiency is often the primary design goal when using a dc/dc converter. Many design requirements involve converting the battery voltage to a low supply voltage. Although a linear regulator can be used, it cannot achieve the efficiency ...
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)

... Digital circuits simplify transistor operation that allows devices to be conceived as switches. Advent of Vacuum tube created a huge impact on electronics industry but had certain hindrances like high power and hundreds of anode voltage. The invention of transistor was a revolutionary step in microe ...
VT4 instructions rev2.indd
VT4 instructions rev2.indd

... When testing for the presence of voltage in multicore cables always run the probe tip along a short length of cable so as to overcome the shielding effect of the natural twist in conductors. ...
< 1 ... 521 522 523 524 525 526 527 528 529 ... 1089 >

Three-phase electric power



Three-phase electric power is a common method of alternating-current electric power generation, transmission, and distribution. It is a type of polyphase system and is the most common method used by electrical grids worldwide to transfer power. It is also used to power large motors and other heavy loads. A three-phase system is usually more economical than an equivalent single-phase or two-phase system at the same line to ground voltage because it uses less conductor material to transmit electrical power.The three-phase system was independently invented by Galileo Ferraris, Mikhail Dolivo-Dobrovolsky, Jonas Wenström and Nikola Tesla in the late 1880s.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report