MAX17242/MAX17243 3.5V–36V, 2A/3A, Synchronous Buck
... The MAX17242/MAX17243 are 2A/3A current-mode stepdown converters with integrated high-side and lowside MOSFETs. The low-side MOSFET enables fixedfrequency, forced-PWM operation in light-load applications. The devices operate with input voltages from 3.5V to 36V while using only 15µA quiescent curren ...
... The MAX17242/MAX17243 are 2A/3A current-mode stepdown converters with integrated high-side and lowside MOSFETs. The low-side MOSFET enables fixedfrequency, forced-PWM operation in light-load applications. The devices operate with input voltages from 3.5V to 36V while using only 15µA quiescent curren ...
ZXSC100 SINGLE CELL DC-DC CONVERTER SOLUTION Description
... The ZXSC100 is non-synchronous PFM, DC-DC controller IC which, when combined with a high performance external transistor, enables the production of a high efficiency boost converter for use in single cell applications. A block diagram is shown for the ZXSC100 on page 2. A shutdown circuit turns the ...
... The ZXSC100 is non-synchronous PFM, DC-DC controller IC which, when combined with a high performance external transistor, enables the production of a high efficiency boost converter for use in single cell applications. A block diagram is shown for the ZXSC100 on page 2. A shutdown circuit turns the ...
Attachment - CEE
... X (Average Load losses furnished – Load losses guaranteed)] X Total number of Units. This will apply for all units in each line item of the purchase order with no credits back to manufacturer. ...
... X (Average Load losses furnished – Load losses guaranteed)] X Total number of Units. This will apply for all units in each line item of the purchase order with no credits back to manufacturer. ...
Introduction to Laboratory Instruments
... After all measurements are taken, set the resolution back to 5-1/2 digits. Turn the Hewlett-Packard power supply off. Detailed Procedure for Measuring Variable Power Supply Voltage Set the voltage on the Hewlett-Packard power supply to 1.123 VDC by first pressing the "VSET" key, then keying in "1.12 ...
... After all measurements are taken, set the resolution back to 5-1/2 digits. Turn the Hewlett-Packard power supply off. Detailed Procedure for Measuring Variable Power Supply Voltage Set the voltage on the Hewlett-Packard power supply to 1.123 VDC by first pressing the "VSET" key, then keying in "1.12 ...
MAX4450/MAX4451 Ultra-Small, Low-Cost, 210MHz, Single-Supply Op Amps with Rail-to-Rail Outputs General Description
... The MAX4450 single and MAX4451 dual op amps are unity-gain-stable devices that combine high-speed performance with rail-to-rail outputs. Both devices operate from a +4.5V to +11V single supply or from ±2.25V to ±5.5V dual supplies. The common-mode input voltage range extends beyond the negative powe ...
... The MAX4450 single and MAX4451 dual op amps are unity-gain-stable devices that combine high-speed performance with rail-to-rail outputs. Both devices operate from a +4.5V to +11V single supply or from ±2.25V to ±5.5V dual supplies. The common-mode input voltage range extends beyond the negative powe ...
Owner`s Manual
... consumed by the microwave oven. The microwave oven will consume 40% to 100% more than its advertised cooking power. Check the rating sticker on the back of the oven to determine its actual power draw. The 1500 W inverter will operate a small microwave oven (0.2 to 3.0 cubic foot capacity) that draws ...
... consumed by the microwave oven. The microwave oven will consume 40% to 100% more than its advertised cooking power. Check the rating sticker on the back of the oven to determine its actual power draw. The 1500 W inverter will operate a small microwave oven (0.2 to 3.0 cubic foot capacity) that draws ...
Catalog - Maalouf for General Electricity sarl
... Today ICAR produces different type of capacitors, from the lighting and single phase motor types to the ones for power electronics (electric traction, industrial services) and those of medium voltage. The various characteristics demanded to these products in terms of electric, mechanical and thermal ...
... Today ICAR produces different type of capacitors, from the lighting and single phase motor types to the ones for power electronics (electric traction, industrial services) and those of medium voltage. The various characteristics demanded to these products in terms of electric, mechanical and thermal ...
- ibookfi.com
... • The 60 Hz generator set offers a UL 2200 listing. • The generator set accepts rated load in one step. • The generator set complies with ISO 8528-5, Class G2, requirements for transient performance in all generator set configurations. Select the DecisionMaker™ 550 controller for improved voltage re ...
... • The 60 Hz generator set offers a UL 2200 listing. • The generator set accepts rated load in one step. • The generator set complies with ISO 8528-5, Class G2, requirements for transient performance in all generator set configurations. Select the DecisionMaker™ 550 controller for improved voltage re ...
AN-EVAL3AR4780JZ
... secondary side control regulation. It is especially suitable for small power supply such as DVD player, set-top box, game console, charger and auxiliary power of high power system, etc. The ICE3AR4780JZ is the latest version of the CoolSET®. Besides having the basic features of the F3R CoolSET® such ...
... secondary side control regulation. It is especially suitable for small power supply such as DVD player, set-top box, game console, charger and auxiliary power of high power system, etc. The ICE3AR4780JZ is the latest version of the CoolSET®. Besides having the basic features of the F3R CoolSET® such ...
DS1818 3.3V EconoReset with Pushbutton FEATURES PIN ASSIGNMENT
... NOTES: 1. All voltages are referenced to ground. 2. Measured with VCC ³ 2.7V. 3. A 1 kW external pull-up resistor may be required in some applications for proper operation of the microprocessor reset control circuit. 4. Measured with RST output open. 5. Measured with 2.7V £ VCC £ 3.3V. 6. tR = 5 ms. ...
... NOTES: 1. All voltages are referenced to ground. 2. Measured with VCC ³ 2.7V. 3. A 1 kW external pull-up resistor may be required in some applications for proper operation of the microprocessor reset control circuit. 4. Measured with RST output open. 5. Measured with 2.7V £ VCC £ 3.3V. 6. tR = 5 ms. ...
P85452_003 - Ceiling
... NOTE: Check the minimum and maximum output of the power supply and standby battery and subtract the voltage drop from the circuit wiring resistance to determine the applied voltage to the strobes. The maximum wire impedance between strobes shall not exceed 35 ohms. NOTE: Strobes are not designed to ...
... NOTE: Check the minimum and maximum output of the power supply and standby battery and subtract the voltage drop from the circuit wiring resistance to determine the applied voltage to the strobes. The maximum wire impedance between strobes shall not exceed 35 ohms. NOTE: Strobes are not designed to ...
70 W HID lamp ballast based on the L6569, L6385E and L6562A
... occurs. LIC01 is latched to on-state. The LIC01 is turned off when discharging a current lower than the holding current (IH). Then LIC01 returns to the off-state. In such a case, a voltage pulse is generated on Lp. With the turn ratio 1:n of T1, the high voltage across C2 is generated and remains co ...
... occurs. LIC01 is latched to on-state. The LIC01 is turned off when discharging a current lower than the holding current (IH). Then LIC01 returns to the off-state. In such a case, a voltage pulse is generated on Lp. With the turn ratio 1:n of T1, the high voltage across C2 is generated and remains co ...
Distribution Lines Design
... Design consideration Prestressed concrete poles while serving their function are subjected to mechanical loads. They will be broken down if the bending moment caused by the mechanical loads overcome their capacities. Thus, it is very important to examine the capacity of poles during a design process ...
... Design consideration Prestressed concrete poles while serving their function are subjected to mechanical loads. They will be broken down if the bending moment caused by the mechanical loads overcome their capacities. Thus, it is very important to examine the capacity of poles during a design process ...
PowerPoint-Präsentation
... messages, also for further processing within the device or the control system Device-internal fault logging with time stamp Time stamp marking of individually selectable status, warning and fault messages Value of the last tripping current Checkback faults (e.g. no current flow in the main c ...
... messages, also for further processing within the device or the control system Device-internal fault logging with time stamp Time stamp marking of individually selectable status, warning and fault messages Value of the last tripping current Checkback faults (e.g. no current flow in the main c ...
MAX3212 +2.7V to +3.6V-Powered, 1µA Supply Current, 3-Driver/5-Receiver, True RS-232 Transceiver _______________General Description
... is intended for 2.7V to 3.6V-powered EIA/TIA-232E and V.28/V.24 serial interface. True RS-232 levels are maintained across the operating range. A guaranteed data rate of 235kbps provides compatibility with popular software for communicating with personal computers. Supply current is reduced to 1 µA ...
... is intended for 2.7V to 3.6V-powered EIA/TIA-232E and V.28/V.24 serial interface. True RS-232 levels are maintained across the operating range. A guaranteed data rate of 235kbps provides compatibility with popular software for communicating with personal computers. Supply current is reduced to 1 µA ...
MAX16936,38 - Maxim Part Number Search
... MOSFETs designed to operate with an external Schottky diode for better efficiency. The low-side MOSFET enables fixed-frequency forced-PWM (FPWM) operation under light-load applications. The devices operate with input voltages from 3.5V to 36V, while using only 28µA quiescent current at no load. The ...
... MOSFETs designed to operate with an external Schottky diode for better efficiency. The low-side MOSFET enables fixed-frequency forced-PWM (FPWM) operation under light-load applications. The devices operate with input voltages from 3.5V to 36V, while using only 28µA quiescent current at no load. The ...
Inverters
... will be bulky since cutoff frequency is low difficult to remove harmonics since at the same time must ensure fundamental component is not attenuated. ...
... will be bulky since cutoff frequency is low difficult to remove harmonics since at the same time must ensure fundamental component is not attenuated. ...
Three-phase electric power
Three-phase electric power is a common method of alternating-current electric power generation, transmission, and distribution. It is a type of polyphase system and is the most common method used by electrical grids worldwide to transfer power. It is also used to power large motors and other heavy loads. A three-phase system is usually more economical than an equivalent single-phase or two-phase system at the same line to ground voltage because it uses less conductor material to transmit electrical power.The three-phase system was independently invented by Galileo Ferraris, Mikhail Dolivo-Dobrovolsky, Jonas Wenström and Nikola Tesla in the late 1880s.