Comparing Performance of Current Ramp and Voltage Ramp Hot Swap Controller ICs
... requirements such as PCI, Compact PCI, USB, 1394, and telecom/datacom applications. Hot swap design considerations must be addressed early in the system design program to achieve the desired high availability feature required by the application. The design considerations address a number of phenomen ...
... requirements such as PCI, Compact PCI, USB, 1394, and telecom/datacom applications. Hot swap design considerations must be addressed early in the system design program to achieve the desired high availability feature required by the application. The design considerations address a number of phenomen ...
Digital Panel Meters - Datel Digital Meters
... • Two AC power options: 85-140Vac & 170-264Vac (50/60Hz) Displays the true-rms value of non-sinusoidal AC currents and provide a user settable, over current alarm function. When the preset over current level is exceeded, the LED display continuously flashes from high to low intensity. A built-in curr ...
... • Two AC power options: 85-140Vac & 170-264Vac (50/60Hz) Displays the true-rms value of non-sinusoidal AC currents and provide a user settable, over current alarm function. When the preset over current level is exceeded, the LED display continuously flashes from high to low intensity. A built-in curr ...
liquid-filled, medium-voltage transformers
... 835.3100. The base fluid shall be 100% derived from edible seed oils and food grade performance enhancing additives. The fluid shall not require genetically altered seeds for its base oil. The fluid shall result in zero mortality when tested on trout fry per OECD G.L. 203. The fluid shall be certifi ...
... 835.3100. The base fluid shall be 100% derived from edible seed oils and food grade performance enhancing additives. The fluid shall not require genetically altered seeds for its base oil. The fluid shall result in zero mortality when tested on trout fry per OECD G.L. 203. The fluid shall be certifi ...
Final Draft Standards Controllers ed 3
... c) Measure the current consumption of the charge controller without load. The no-load loss of the battery charge controller should not exceed 0.5% of the rated load current. 14. VERIFICATION OF RELIABILITY OF SERVICE WITH APPLIED FULL PV MODULE VOLTAGE AT ...
... c) Measure the current consumption of the charge controller without load. The no-load loss of the battery charge controller should not exceed 0.5% of the rated load current. 14. VERIFICATION OF RELIABILITY OF SERVICE WITH APPLIED FULL PV MODULE VOLTAGE AT ...
Not Recommended for New Designs
... the value of the on-chip series termination resistor and channel resistance of the output driver FET. When driving loads where transmission line effects will be a factor, output pins should be appropriately terminated with controlled impedance PCB traces. 2. tPSK(P-P) is the magnitude of the differe ...
... the value of the on-chip series termination resistor and channel resistance of the output driver FET. When driving loads where transmission line effects will be a factor, output pins should be appropriately terminated with controlled impedance PCB traces. 2. tPSK(P-P) is the magnitude of the differe ...
LVDT SELECTION, HANDLING AND INSTALLATION GUIDELINES APPLICATION NOTE Preamble
... For customers who prefer to use their own connecting rods, ferromagnetic metals (such as AISI 400 series stainless steels for example) must not be used as they will severely interfere with the LVDT operation. Low resistivity metals (such as aluminum, brass, etc.) must also be avoided as they will dr ...
... For customers who prefer to use their own connecting rods, ferromagnetic metals (such as AISI 400 series stainless steels for example) must not be used as they will severely interfere with the LVDT operation. Low resistivity metals (such as aluminum, brass, etc.) must also be avoided as they will dr ...
TDA8922B 2 x 50 W class-D power amplifier
... threshold level, the system is restarted again after 100 ms. If the supply voltage exceeds ±33 V the OverVoltage Protection (OVP) circuit is activated and the power stages will shut-down. It is re-enabled as soon as the supply voltage drops below the threshold level. So in this case no timer of 100 ...
... threshold level, the system is restarted again after 100 ms. If the supply voltage exceeds ±33 V the OverVoltage Protection (OVP) circuit is activated and the power stages will shut-down. It is re-enabled as soon as the supply voltage drops below the threshold level. So in this case no timer of 100 ...
HPH-12/30-D48 Series
... Certain applications and/or safety agencies may require fuses at the inputs of power conversion components. Fuses should also be used when there is the possibility of sustained input voltage reversal which is not current-limited. For greatest safety, we recommend a fast blow fuse installed in the un ...
... Certain applications and/or safety agencies may require fuses at the inputs of power conversion components. Fuses should also be used when there is the possibility of sustained input voltage reversal which is not current-limited. For greatest safety, we recommend a fast blow fuse installed in the un ...
PAM2321 Description Pin Assignments
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
bq769x0 boot switch alternatives
... too long, the temperature reading obtained on TS1 is altered. The pullup would also provide a load on the cells. Since the load is inside the protection loop, the battery cannot stop the discharge. AC coupling the boot signal could prevent a continuous discharge and may be suitable in some designs. ...
... too long, the temperature reading obtained on TS1 is altered. The pullup would also provide a load on the cells. Since the load is inside the protection loop, the battery cannot stop the discharge. AC coupling the boot signal could prevent a continuous discharge and may be suitable in some designs. ...
MAX16128/MAX16129 Evaluate: MAX16128/MAX16129 Evaluation Kits General Description
... EV kit includes a zener diode (D1) between the input supply (IN) of the device and COM. To increase the negative input-voltage protection range, a diode between COM (ground of the protection device) and SYSGND (ground carrying load current), D5, must be installed. A series surface-mount resistor (R5 ...
... EV kit includes a zener diode (D1) between the input supply (IN) of the device and COM. To increase the negative input-voltage protection range, a diode between COM (ground of the protection device) and SYSGND (ground carrying load current), D5, must be installed. A series surface-mount resistor (R5 ...
armature winding
... simplex winding. The voltage induced in each path is assumed to both to be same and should be if the reluctance of each magnetic path is the same, so that the lines of flux cut by each inductor of each path are the same. However wear of the bearings or deflection of the armature shaft may cause th ...
... simplex winding. The voltage induced in each path is assumed to both to be same and should be if the reluctance of each magnetic path is the same, so that the lines of flux cut by each inductor of each path are the same. However wear of the bearings or deflection of the armature shaft may cause th ...
RHRD660S9A_F085 6A, 600V Hyperfast Diodes Features
... warranty issues that may arise. Fairchild will not provide any warranty coverage or other assistance for parts bought from Unauthorized Sources. Fairchild is committed to combat this global problem and encourage our customers to do their part in stopping this practice by buying direct or from author ...
... warranty issues that may arise. Fairchild will not provide any warranty coverage or other assistance for parts bought from Unauthorized Sources. Fairchild is committed to combat this global problem and encourage our customers to do their part in stopping this practice by buying direct or from author ...
Single-Line Diagrams
... equipment and available spares. It shows a correct power distribution path from the incoming power source to each downstream load — including the ratings and sizes of each piece of electrical equipment, their circuit conductors, and their protective devices. In many facilities, loads are continually ...
... equipment and available spares. It shows a correct power distribution path from the incoming power source to each downstream load — including the ratings and sizes of each piece of electrical equipment, their circuit conductors, and their protective devices. In many facilities, loads are continually ...
Power-Electronics-Based Energy Management
... service a 20-A circuit, and for that hardware, we will accomplish the unintentional islanding testing. The EMS control algorithm was developed with the following goals, listed here in order of priority: 1) power must be available to the critical loads at all times; 2) reduce the peak power absorbed ...
... service a 20-A circuit, and for that hardware, we will accomplish the unintentional islanding testing. The EMS control algorithm was developed with the following goals, listed here in order of priority: 1) power must be available to the critical loads at all times; 2) reduce the peak power absorbed ...
68 Voltage and Current in Simple Circuits (Voltage Sensor, Current
... Voltage is the ratio of electric potential energy to charge. One volt is one joule of energy per one coulomb of charge. Current is the volume of electric charge, or the number of charges per second moving past a point in an electric circuit. The unit for current is the ampere and one ampere is one c ...
... Voltage is the ratio of electric potential energy to charge. One volt is one joule of energy per one coulomb of charge. Current is the volume of electric charge, or the number of charges per second moving past a point in an electric circuit. The unit for current is the ampere and one ampere is one c ...
LM3914 Dot/Bar Display Driver (Rev. B)
... The LM3914 is relatively low-powered itself, and since any number of LEDs can be powered from about 3V, it is a very efficient display driver. Typical standby supply current (all LEDs OFF) is 1.6mA (2.5mA max). However, any reference loading adds 4 times that current drain to the V+ (pin 3) supply i ...
... The LM3914 is relatively low-powered itself, and since any number of LEDs can be powered from about 3V, it is a very efficient display driver. Typical standby supply current (all LEDs OFF) is 1.6mA (2.5mA max). However, any reference loading adds 4 times that current drain to the V+ (pin 3) supply i ...
MAX868 Regulated, Adjustable -2x Inverting Charge Pump General Description
... next to FB (Figures 7 and 8). Should it become necessary in the final layout, leave room to parallel a feedforward capacitor across R1. ...
... next to FB (Figures 7 and 8). Should it become necessary in the final layout, leave room to parallel a feedforward capacitor across R1. ...
Appendix A UC Irvine shall develop and employ work practices and
... Check box to indicate if areas have been assessed ...
... Check box to indicate if areas have been assessed ...
LM4559F
... The LM4559xxx are low noise operational amplifiers with high gain and wide bandwidth. They have good performance of input referred noise voltage (5 nV/ Hz ) and total harmonic distortion (0.0003%). These are suitable for audio applications and active filter. ...
... The LM4559xxx are low noise operational amplifiers with high gain and wide bandwidth. They have good performance of input referred noise voltage (5 nV/ Hz ) and total harmonic distortion (0.0003%). These are suitable for audio applications and active filter. ...
Three-phase electric power
Three-phase electric power is a common method of alternating-current electric power generation, transmission, and distribution. It is a type of polyphase system and is the most common method used by electrical grids worldwide to transfer power. It is also used to power large motors and other heavy loads. A three-phase system is usually more economical than an equivalent single-phase or two-phase system at the same line to ground voltage because it uses less conductor material to transmit electrical power.The three-phase system was independently invented by Galileo Ferraris, Mikhail Dolivo-Dobrovolsky, Jonas Wenström and Nikola Tesla in the late 1880s.