• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
AC motor - induction2
AC motor - induction2

... • The torque, slip, and current will approach zero for a “no mechanical torque” load condition. This condition is analogous to an open secondary transformer. ABD RAHIM 2008 ...
Starting Time Calculation for Induction Motor
Starting Time Calculation for Induction Motor

... the heavy applications requirement. Some are considered large even in comparison to the total capacity of large industrial power systems. Starting of such large motors can cause adverse effects to any locally connected load, other motors and also to buses, which are electrically remote from the poin ...
ISL45042A - Intersil
ISL45042A - Intersil

... and R2 (see Figure 1). The voltage difference between the VOUT pin and ISET pin (see Figure 5) has to be greater than 1.75V. This will keep the output MOS transistor in the saturation region. Expected current settings and 7-bit accuracy occurs when the output MOS transistor is operating in the satur ...
Inverter Systems
Inverter Systems

... • DC 24 V NC for supply of the HSCI components (connector X90, protective extra-low voltage, safely separated) • Only on UVR 170D(W), UV 130D: DC 24 V PLC for supply of the PLC components (connector X90, basic insulation) The integrated power pack is buffered via the DC link, thereby ensuring that i ...
FINAL SAFETY ANALYSIS REPORT CHAPTER 8 ELECTRIC POWER BBNPP
FINAL SAFETY ANALYSIS REPORT CHAPTER 8 ELECTRIC POWER BBNPP

... BBNPP transmission lines will utilize one new on-site corridor and the on-site Susquehanna-Roseland corridor for interconnections to the existing offsite power transmission grid as shown in Figure 8.2-1. The two circuits are supported on separate structures, which are located to minimize the likelih ...
Grounding and Bonding CEC-10 [rev-9]
Grounding and Bonding CEC-10 [rev-9]

... grounding conductor connections. For grounding and bonding of rigs, the use of a suitably rated copper or aluminum lugs with associated buss is acceptable. Pliers-style, screw-type or spring enabled booster cable clamps are not considered acceptable as they may be easily dislodged. It is important t ...
Electrical Services Audit - Gold Coast Hospital
Electrical Services Audit - Gold Coast Hospital

... Each panel is connected to a separate RCD, however all RCDs are on the one circuit. No UPS power or line isolation monitored power is available. This arrangement is not considered acceptable. Staff advised that on at least one occasion the single circuit to a theatre overloaded and required an elect ...
$doc.title

... Supply voltage VDD + (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 V Supply voltage VDD − (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
STP 3 & 4 8.2  Offsite Power Systems
STP 3 & 4 8.2 Offsite Power Systems

... transformer because unit startup is accomplished from the normal preferred power, which is backfed over the main power circuit to the unit auxiliary transformers. The reserve auxiliary transformer serves no startup function. The operational configurations are such that the FOA ratings of the reserve ...
TPS65632 Triple-Output AMOLED Display Power Supply (Rev. A)
TPS65632 Triple-Output AMOLED Display Power Supply (Rev. A)

... voltages of 5.8 V and 7.7 V, selected by the SELP2 pin. AVDD = 7.7 V when SELP2 is low or left floating, and AVDD = 5.8 V when SELP2 is high. 7.3.4 Soft Start and Start-Up Sequence The devices feature a soft-start function to limit inrush current. Boost converter 2 (AVDD) is enabled when EN goes hig ...
Aalborg Universitet Modulation Scheme for Harmonic Reduction
Aalborg Universitet Modulation Scheme for Harmonic Reduction

... Speed Drive (ASD) systems are commonly employed with diode rectifiers or Silicon Controlled Rectifiers (SCR) as the front-ends (i.e., ac-dc converters). Apart from low cost, small volume, and high reliability, harmonic currents are significantly produced at the grid side by the rectification apparat ...
Aalborg Universitet Analysis and Modeling of Transformerless Photovoltaic Inverter Systems Kerekes, Tamas
Aalborg Universitet Analysis and Modeling of Transformerless Photovoltaic Inverter Systems Kerekes, Tamas

... This thesis is written in the frame of two research projects: the first, entitled “Transformerlose solcelle invertere”, was financially supported by the Eltra PSO-F&U contract nr. 5780 signed between Aalborg University and Energinet in cooperation with Powerlynx A/S, now Danfoss Solar A/S. The secon ...
BD3550HFN
BD3550HFN

... Programming Notes and Precautions IC output voltage can be set with a configuration formula using the values for the internal reference output voltage (VFB)and the output voltage resistors (R1, R2). Select resistance values that will avoid the impact of the VREF current (±100nA). The recommended tot ...
Universal AC Input, 5 V or 12 V Output, 20 Watt Power Supply
Universal AC Input, 5 V or 12 V Output, 20 Watt Power Supply

... For applications requiring 10 to 15 watts output, the NCP1126 version of the controller can be used which has exactly the same circuitry as the NCP1129, but with a different MOSFET. For optimum thermal characteristics, the printed circuit board should be laid out to include clad “pours” around pins ...
Voltage Oriented Control of Three
Voltage Oriented Control of Three

... The topologies b) and c) use PWM rectifier modules with a very low current rating (20‐25% level of  RMS current comparable with e) topology). Hence they have a low cost potential and provide only  the possibility of regenerative braking mode b) or active filtering c).  Figure d) presents a converter ...
Reference Guide The Open Distribution System Simulator
Reference Guide The Open Distribution System Simulator

DS-100C I-V CURVE TRACER User Manual
DS-100C I-V CURVE TRACER User Manual

LMD M12 Motion Control NEMA 17 - Schneider Electric Motion USA
LMD M12 Motion Control NEMA 17 - Schneider Electric Motion USA

Text for specifiers - Industrial Solutions
Text for specifiers - Industrial Solutions

... available: 20, 24, 40 and 63A. The 20A contactors have an AC-coil and as a consequence can only be used on AC. The 24, 40 and 63A-contactors all have a DC-coil which makes them absolutely noise-free (NO 50Hznoise). A built-in rectifier bridge allows the use of AC as well as on DC at all times. The c ...
Data Sheet
Data Sheet

... Input pins of an IC are often connected to the gate of a MOS transistor. The gate has extremely high impedance and extremely low capacitance. If left unconnected, the electric field from the outside can easily charge it. The small charge acquired in this way is enough to produce a significant effect ...
Application Report www.BDTIC.com/TI Understanding Boost Power
Application Report www.BDTIC.com/TI Understanding Boost Power

... drain-to-source resistance, RDS(on) , has a small voltage drop of VDS . There is also a small voltage drop across the dc resistance of the inductor equal to IL × RL . Thus the input voltage, VI , minus losses, (VDS + IL × RL ), is applied across inductor L. Diode CR1 is off during this time because ...
A Bi-Polar Triple-Output Converter with Duty Cycle Estimation
A Bi-Polar Triple-Output Converter with Duty Cycle Estimation

... for a switching frequency of 50 KHz is L1 as 141 µH, L2 as 87 µH, d1 as 0.52, d2 as 0.09 and d3 as 0.39. The simulation of the system was done using PSIM software with the specifications of the converter as given in Table 1. The simulation waveforms for the inductor currents, switch currents and out ...
BD9106FVM-LB
BD9106FVM-LB

... The parts list presented above is an example of recommended parts. Although the parts are sound, actual circuit characteristics should be checked on your application carefully before use. Be sure to allow sufficient margins to accommodate variations between external devices and this IC when employin ...
WECC VGITF White Paper - Draft - Western Electricity Coordinating
WECC VGITF White Paper - Draft - Western Electricity Coordinating

... Interconnection Report published in June 2015, wind capacity has increased by more than 150% to 24.3 GW and solar capacity by 14 times to 8.4 GW. The focus of this white paper will be on wind and solar generation interconnected to the bulk transmission system. Wind and solar generation interconnecte ...
Double Tail Comparator Using FinFET
Double Tail Comparator Using FinFET

< 1 ... 208 209 210 211 212 213 214 215 216 ... 1089 >

Three-phase electric power



Three-phase electric power is a common method of alternating-current electric power generation, transmission, and distribution. It is a type of polyphase system and is the most common method used by electrical grids worldwide to transfer power. It is also used to power large motors and other heavy loads. A three-phase system is usually more economical than an equivalent single-phase or two-phase system at the same line to ground voltage because it uses less conductor material to transmit electrical power.The three-phase system was independently invented by Galileo Ferraris, Mikhail Dolivo-Dobrovolsky, Jonas Wenström and Nikola Tesla in the late 1880s.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report