• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Modelling of Single-Phase Induction Motor with External
Modelling of Single-Phase Induction Motor with External

... and can be dissipated easily  The start-up and operating characteristics of singlephase induction motors with external rotor can be improved by covering the rotor with a conducting shell joining the two end rings ...
WEEK 5 sizing 1(2)
WEEK 5 sizing 1(2)

... inverter is located far from the point of connection to the grid then the AC voltage drop is also need to be included in this 5% 5.4.5 Inverter efficiency - There are losses in the inverter due to transformer losses, power switching and self consumption eg monitoring etc. These losses are expressed ...
PS9905 Data Sheet R08DS0058EJ0100
PS9905 Data Sheet R08DS0058EJ0100

... (3) Pin 1, 4 (which is an NC*1 pin) can either be connected directly to the GND pin on the LED side or left open. Also, Pin 6 (which is an NC*1 pin) can either be connected directly to the GND pin on the detector side or left open. Unconnected pins should not be used as a bypass for signals or for a ...
Field Oriented Stepper Motor Control
Field Oriented Stepper Motor Control

Product note Medium and high voltage generators for
Product note Medium and high voltage generators for

... windings and vacuum pressure impregnation – which has proven itself for more than 30 years in tens of thousands of large motors and generators that are operating successfully all over the world. Our advanced insulation system gives the windings superior strength to withstand vibration, and mechanica ...
OPA3695
OPA3695

... exceptional 4300V/µs slew rate and a very high 900MHz bandwidth (G = +2V/V) to provide an amplifier that is ideal for the most demanding video applications. The device versatility is enhanced with a low 1.8nV/√Hz input voltage noise and an output stage that can swing within 1V from the supply rail t ...
MN800012EN
MN800012EN

... In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or otherwise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to damage or loss of use of equipment, plant or power ...
Email Q4A Polyphase Electronic (E3) Meter Customer Installations
Email Q4A Polyphase Electronic (E3) Meter Customer Installations

... line is the meter outline). The Q4A meter will only be issued with the larger terminal cover (42mm added to the bottom of the diagram in Appendix A). NB. Customers must allow a minimum ‘footprint area’ of 340mm high x 200mm wide on their new switchboards to accommodate this meter (refer to CIA 1211B ...
0.18µm PHASE / FREQUENCY DETECTOR AND CHARGE PUMP
0.18µm PHASE / FREQUENCY DETECTOR AND CHARGE PUMP

... DVB-H operating frequency in US is between 1.67 and 1.675GHz, while for the European operating frequency is between 470 and 867MHz. Since DVB-H originally derived from DVB-T, it has all its standards with some new additions to make it suitable for handheld devices. One of these additions is the time ...
switches - (HOCL)
switches - (HOCL)

... battery at about 2.15 V per cell while supplying continuous load. Facility shall be provided for minor adjustment of float voltage to regulate the trickle charging current and/or compensate line drop voltage. 8. The boost charger circuit shall be suitable for charging the battery at the maximum char ...
AK1543 - Asahi Kasei Microdevices
AK1543 - Asahi Kasei Microdevices

LM26003/LM26003Q 3A Switching Regulator with High Efficiency
LM26003/LM26003Q 3A Switching Regulator with High Efficiency

... 20-Pin HTSSOP Package Thermal Shut Down ...
D.J. Perreault and V. Caliskan, “Automotive Power Generation and Control,” IEEE Transactions on Power Electronics , Vol. 19, No. 3, May 2004, pp. 618-630.
D.J. Perreault and V. Caliskan, “Automotive Power Generation and Control,” IEEE Transactions on Power Electronics , Vol. 19, No. 3, May 2004, pp. 618-630.

... voltage and output current. If the alternator is used at the designed output voltage of 14 V, then the output power capability across speed is represented by the vertical 14-V locus intersecting the curves of Fig. 3. The alternator delivers its maximum idle speed power near the 14-V design voltage. ...
MP3422, 6.5A, 600kHz High Efficiency
MP3422, 6.5A, 600kHz High Efficiency

... Output Disconnect The MP3422 is designed to allow true output disconnect by eliminating body diode conduction of the internal PMOS rectifier. This allows VOUT to go to zero volts during shutdown, or isolate and maintain an external bias on VOUT. It also allows for inrush current limit at start-up, m ...
TPS65030 数据资料 dataSheet 下载
TPS65030 数据资料 dataSheet 下载

... Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings only and functional operation of the device at these or any other conditions beyond those indicated under recommended operating conditions is not implied. Exposure to absolu ...
AP7335A-50 N E W P R O D U C T 300mA, LOW QUIESCENT
AP7335A-50 N E W P R O D U C T 300mA, LOW QUIESCENT

... B. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or to affect its safety or effectiveness. Customers represent that they have all necessary expertise in the safety and regul ...
AAT4610B 数据资料DataSheet下载
AAT4610B 数据资料DataSheet下载

... MOSFET power switch designed for high-side load switching applications. This switch operates with inputs ranging from 2.4V to 5.5V, making it ideal for both 3V and 5V systems. An integrated current-limiting circuit protects the input supply against large currents which may cause the supply to fall o ...
Breakdown of Gasses - Department of Electrical Engineering
Breakdown of Gasses - Department of Electrical Engineering

... kinetic energy of the electrons is lost and part is transmitted to the neutral molecule. If this molecule gains sufficient energy (more than the energy Ei necessary for ionisation to occur), it may ionise by collision. The (mean) number of ionising collisions by one electron per unit drift across th ...
ADM209 数据手册DataSheet 下载
ADM209 数据手册DataSheet 下载

... The EIA-232-E standard requires transmitters that will deliver ±5 V minimum on the transmission channel and receivers that can accept signal levels down to ±3 V. The ADM206–ADM211/ ADM213 meet these requirements by integrating step-up voltage converters and level shifting transmitters and receivers ...
WARD LEONARD CONTROL SYSTEM
WARD LEONARD CONTROL SYSTEM

... drive system to control drive motors. A steam engine was the prime mover which ran the prime generator and the smaller exciting generator which produced the exciting power for the prime generator and drive motors. Before the inventors of this locomotive started to build it, they did some research on ...
Wireless Clamp Meter - Fieldpiece Instruments
Wireless Clamp Meter - Fieldpiece Instruments

... surface with the heavy-duty magnet and when the job is done, snap your test leads in the back case for tidy and convenient storage. See both voltage and amperage readings at the same time on the large dual display, even in low light conditions using the bright blue backlight. Easily see your amperag ...
Electrical safety costs little … … a human life is priceless
Electrical safety costs little … … a human life is priceless

... installed to facilitate the automatic changeover from the main distribution system to the electrical safety power source feeding essential loads. This automatic changeover device requires a „safe separation“ between systems as defined in IEC 60364-5-536.2.2.4, which does not allow semiconductor devi ...
Simple Way to Achieve Changeable Holding Current of DRV8x
Simple Way to Achieve Changeable Holding Current of DRV8x

... Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered documentation. Info ...
INSTRUMENT TRANSFORMER DIMENSIONING FOR SUBSTATIONS Ronny Mustajärvi
INSTRUMENT TRANSFORMER DIMENSIONING FOR SUBSTATIONS Ronny Mustajärvi

High-Voltage Energy Storage: The Key to Efficient Holdup
High-Voltage Energy Storage: The Key to Efficient Holdup

... 9.2 ms when rise and fall times are included). The 5 ms is the time in which a fuse can blow when there is a short circuit on a module or a shortcircuited module is plugged into the system. Many other similar examples can be enumerated, both for DC and AC bus voltages. ...
< 1 ... 202 203 204 205 206 207 208 209 210 ... 1089 >

Three-phase electric power



Three-phase electric power is a common method of alternating-current electric power generation, transmission, and distribution. It is a type of polyphase system and is the most common method used by electrical grids worldwide to transfer power. It is also used to power large motors and other heavy loads. A three-phase system is usually more economical than an equivalent single-phase or two-phase system at the same line to ground voltage because it uses less conductor material to transmit electrical power.The three-phase system was independently invented by Galileo Ferraris, Mikhail Dolivo-Dobrovolsky, Jonas Wenström and Nikola Tesla in the late 1880s.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report