SIOV metal oxide varistors, General technical information
... circuit designers may generally want to know about the largest possible leakage current at given operating voltage. Therefore the lower limit of the tolerance band is shown. Righthand part of the curve (> 1 mA): This segment covers the “low-resistance” mode in an overvoltage event, where the circuit ...
... circuit designers may generally want to know about the largest possible leakage current at given operating voltage. Therefore the lower limit of the tolerance band is shown. Righthand part of the curve (> 1 mA): This segment covers the “low-resistance” mode in an overvoltage event, where the circuit ...
PSPICE Lecture #2
... can be used to display DC, AC, and other values in the output (.out) file. Any voltages can be displayed (not just node voltages). • Sweeping sources or components: The circuit can be analyzed as a source or component is varied. (In other words, we will sweep the source or component over a range of ...
... can be used to display DC, AC, and other values in the output (.out) file. Any voltages can be displayed (not just node voltages). • Sweeping sources or components: The circuit can be analyzed as a source or component is varied. (In other words, we will sweep the source or component over a range of ...
Bronco VFD Series Adjustable Frequency Drives
... The SECO Bronco VFD Series are solid-state, variablefrequency AC motor drives. The Bronco VFD utilizes a 115 or 230 VAC, 50/60 Hz, single-phase input, and is factory calibrated for an output of 0 to 60 Hz. They will operate any 1.5 HP or smaller, 208/230-volt three-phase-ACinduction, single-phase pe ...
... The SECO Bronco VFD Series are solid-state, variablefrequency AC motor drives. The Bronco VFD utilizes a 115 or 230 VAC, 50/60 Hz, single-phase input, and is factory calibrated for an output of 0 to 60 Hz. They will operate any 1.5 HP or smaller, 208/230-volt three-phase-ACinduction, single-phase pe ...
Power Electronics Prof. K. Gopakumar Centre for Electronics
... operation. So, PWM mode, we can have the E0, we can control. So, we can control in such a way, a sinusoid average, sinusoidal variation is possible, possible here, E0 side; this is possible. Now, if that is possible; can we have a sinusoidal output voltage? We can have a sinusoidal output voltage l ...
... operation. So, PWM mode, we can have the E0, we can control. So, we can control in such a way, a sinusoid average, sinusoidal variation is possible, possible here, E0 side; this is possible. Now, if that is possible; can we have a sinusoidal output voltage? We can have a sinusoidal output voltage l ...
LTC3892/ - 60V Low IQ, Dual, 2-Phase Synchronous Step
... Note 4: The LTC3892/LTC3892-1/LTC3892-2 is tested in a feedback loop that servos VITH1,2 to a specified voltage and measures the resultant VFB1,2. The specification at 85°C is not tested in production and is assured by design, characterization and correlation to production testing at other temperatu ...
... Note 4: The LTC3892/LTC3892-1/LTC3892-2 is tested in a feedback loop that servos VITH1,2 to a specified voltage and measures the resultant VFB1,2. The specification at 85°C is not tested in production and is assured by design, characterization and correlation to production testing at other temperatu ...
BDTIC www.BDTIC.com/infineon ICB2FL02G
... If the sensed current signal exceeds a second threshold of 1.6V for longer than 500ns during start-up, soft start, ignition mode and pre-run, the IC changes over into a latched shut down. There are further thresholds active at this pin during run mode that detects a capacitive mode operation. A thre ...
... If the sensed current signal exceeds a second threshold of 1.6V for longer than 500ns during start-up, soft start, ignition mode and pre-run, the IC changes over into a latched shut down. There are further thresholds active at this pin during run mode that detects a capacitive mode operation. A thre ...
MAX8792 Single Quick-PWM Step-Down Controller with Dynamic REFIN General Description
... down high-voltage batteries to generate low-voltage core or chipset/RAM bias supplies in notebook computers. The output voltage can be dynamically controlled using the dynamic REFIN, which supports input voltages between 0 to 2V. The REFIN adjustability combined with a resistive voltage-divider on t ...
... down high-voltage batteries to generate low-voltage core or chipset/RAM bias supplies in notebook computers. The output voltage can be dynamically controlled using the dynamic REFIN, which supports input voltages between 0 to 2V. The REFIN adjustability combined with a resistive voltage-divider on t ...
CI23521526
... Rectifires directly give DC output. Traditionally ac and dc conversion systems are used separately for ac and dc loads. Currently no system is available to get AC and DC output simultaneously. Novel concept of multiple converter means that it can give AC and DC output simultaneously using single con ...
... Rectifires directly give DC output. Traditionally ac and dc conversion systems are used separately for ac and dc loads. Currently no system is available to get AC and DC output simultaneously. Novel concept of multiple converter means that it can give AC and DC output simultaneously using single con ...
MAX3325 3V Dual RS-232 Transceiver with LCD Supply and Contrast Controller General Description
... The capacitor type used for C1–C4 is not critical for proper operation; polarized or nonpolarized capacitors can be used. Ceramic chip capacitors with an X7R dielectric provide the best combination of performance, cost, and size. The charge pump requires 0.22µF capacitors for 3.3V operation. Do not ...
... The capacitor type used for C1–C4 is not critical for proper operation; polarized or nonpolarized capacitors can be used. Ceramic chip capacitors with an X7R dielectric provide the best combination of performance, cost, and size. The charge pump requires 0.22µF capacitors for 3.3V operation. Do not ...
modeling and control of the ultracapacitor
... intensively in recent years. The reason for this lies in their efficiency, flexibility, and reliability. There are, however, two important issues to be solved in order to improve the drive system efficiency and reliability, namely, 1) the recovery of the braking energy and 2) the drive-system rideth ...
... intensively in recent years. The reason for this lies in their efficiency, flexibility, and reliability. There are, however, two important issues to be solved in order to improve the drive system efficiency and reliability, namely, 1) the recovery of the braking energy and 2) the drive-system rideth ...
MAX8513/MAX8514 Wide-Input, High-Frequency, Triple-Output Supplies with Voltage Monitor and Power-On Reset General Description
... PWM step-down DC-DC controller and two LDO controllers, a voltage monitor, and a power-on reset for the lowest-cost power-supply and monitoring solution for xDSL modems, routers, gateways, and set-top boxes. The DC-DC controller switching frequency can be set with an external resistor from 300kHz to ...
... PWM step-down DC-DC controller and two LDO controllers, a voltage monitor, and a power-on reset for the lowest-cost power-supply and monitoring solution for xDSL modems, routers, gateways, and set-top boxes. The DC-DC controller switching frequency can be set with an external resistor from 300kHz to ...
A8503 Datasheet - Allegro Microsystems
... device may stay in soft start mode indefinitely, if the output voltage cannot rise to the LED regulation level and the MODE pin is tied high. To avoid this scenario, A8503 has a soft start timeout when the MODE pin is tied low. With the MODE pin low, if the device does not finish soft start during 1 ...
... device may stay in soft start mode indefinitely, if the output voltage cannot rise to the LED regulation level and the MODE pin is tied high. To avoid this scenario, A8503 has a soft start timeout when the MODE pin is tied low. With the MODE pin low, if the device does not finish soft start during 1 ...
FINAL SAFETY ANALYSIS REPORT CHAPTER 8 ELECTRIC POWER CCNPP Unit 3
... Chapel Substation in Anne Arundel County. The other circuit is a single line circuit from the CCNPP site routed northwestward to the Potomac Electric Power Company (PEPCO) Chalk Point Generating Station. Approximately 22 mi (35 km) of the lines in the CCNPP to Waugh Chapel circuit are in Calvert Cou ...
... Chapel Substation in Anne Arundel County. The other circuit is a single line circuit from the CCNPP site routed northwestward to the Potomac Electric Power Company (PEPCO) Chalk Point Generating Station. Approximately 22 mi (35 km) of the lines in the CCNPP to Waugh Chapel circuit are in Calvert Cou ...
Research on High Efficiency Non-Isolated Push-Pull
... inductor and capacitor into these basic second-order converters is a possible method. [8]-[10] introduce a family of fourth-order converters with continuous current. Superbuck and Superboost converters are typical of many of these. The waveforms of the input and output current are triangular, as sho ...
... inductor and capacitor into these basic second-order converters is a possible method. [8]-[10] introduce a family of fourth-order converters with continuous current. Superbuck and Superboost converters are typical of many of these. The waveforms of the input and output current are triangular, as sho ...
MAX769 完备的电源及监控系统,简化设计、降低成本、节省空间
... For free samples & the latest literature: http://www.maxim-ic.com, or phone 1-800-998-8800. For small orders, phone 1-800-835-8769. ...
... For free samples & the latest literature: http://www.maxim-ic.com, or phone 1-800-998-8800. For small orders, phone 1-800-835-8769. ...
ES6U41
... No copying or reproduction of this document, in part or in whole, is permitted without the consent of ROHM Co.,Ltd. The content specified herein is subject to change for improvement without notice. The content specified herein is for the purpose of introducing ROHM's products (hereinafter "Products" ...
... No copying or reproduction of this document, in part or in whole, is permitted without the consent of ROHM Co.,Ltd. The content specified herein is subject to change for improvement without notice. The content specified herein is for the purpose of introducing ROHM's products (hereinafter "Products" ...
SP319
... which accept either TTL or CMOS inputs and output the RS-232 signals with an inverted sense relative to the input logic levels. Typically, the RS-232 output voltage swing is +9V with no load, and +5V minimum with full load. The transmitter outputs are protected against infinite short-circuits to gro ...
... which accept either TTL or CMOS inputs and output the RS-232 signals with an inverted sense relative to the input logic levels. Typically, the RS-232 output voltage swing is +9V with no load, and +5V minimum with full load. The transmitter outputs are protected against infinite short-circuits to gro ...
MAX15090/MAX15090A Evaluate: MAX15090/MAX15090A Evaluation Kits General Description
... a simple timer circuit comprised of U2, R7, and C5 to pull the EN pin low before the time-out delay. Once PG asserts as open-drain, R7 begins to charge C5 to the output voltage (OUT). When C5 charges to 2/3 x OUT, U2 pulls the EN pin low. The EV kit is configured to have EN pulled low after ~22ms. J ...
... a simple timer circuit comprised of U2, R7, and C5 to pull the EN pin low before the time-out delay. Once PG asserts as open-drain, R7 begins to charge C5 to the output voltage (OUT). When C5 charges to 2/3 x OUT, U2 pulls the EN pin low. The EV kit is configured to have EN pulled low after ~22ms. J ...
AN2007-03 7ED020E12-FI-W2
... In case of short circuit, over current or over temperature the /Fault Pin (X5-8) will be switched to low to report an error to the microcontroller. After a definable delay time t=R20*C23 the driver will be switched on again if the fault condition does not exist anymore. So in case of fault condition ...
... In case of short circuit, over current or over temperature the /Fault Pin (X5-8) will be switched to low to report an error to the microcontroller. After a definable delay time t=R20*C23 the driver will be switched on again if the fault condition does not exist anymore. So in case of fault condition ...
Three-phase electric power
Three-phase electric power is a common method of alternating-current electric power generation, transmission, and distribution. It is a type of polyphase system and is the most common method used by electrical grids worldwide to transfer power. It is also used to power large motors and other heavy loads. A three-phase system is usually more economical than an equivalent single-phase or two-phase system at the same line to ground voltage because it uses less conductor material to transmit electrical power.The three-phase system was independently invented by Galileo Ferraris, Mikhail Dolivo-Dobrovolsky, Jonas Wenström and Nikola Tesla in the late 1880s.