PTH08T220W,
... For output voltages ≤ 1.2 V, at nominal operating frequency, the output ripple may increase (typically 2×) when operating at input voltages greater than (VO × 11). When using the SmartSync feature to adjust the switching frequency, see the SmartSync Considerations section of the datasheet for furthe ...
... For output voltages ≤ 1.2 V, at nominal operating frequency, the output ripple may increase (typically 2×) when operating at input voltages greater than (VO × 11). When using the SmartSync feature to adjust the switching frequency, see the SmartSync Considerations section of the datasheet for furthe ...
PAM2845
... 1) Minimize the area of the high current switching loop of the rectifier diode and output capacitor to avoid excessive switching noise. 2) Connect high-current input and output components with short and wide connections. The high-current input loop goes from the positive terminal of the input capaci ...
... 1) Minimize the area of the high current switching loop of the rectifier diode and output capacitor to avoid excessive switching noise. 2) Connect high-current input and output components with short and wide connections. The high-current input loop goes from the positive terminal of the input capaci ...
Stakeholder Comparison Comment Rationale Matrix 2011-09-28 AESO AUTHORITATIVE DOCUMENT PROCESS
... R1.3. Set transmission line relays so they do not operate at or below 115% of the maximum theoretical power transfer capability, using a 90-degree angle between the sending-end and receiving-end voltages and either reactance or complex impedance, of the circuit expressed in amperes, using one of the ...
... R1.3. Set transmission line relays so they do not operate at or below 115% of the maximum theoretical power transfer capability, using a 90-degree angle between the sending-end and receiving-end voltages and either reactance or complex impedance, of the circuit expressed in amperes, using one of the ...
RG series: 1-phase solid state switching solutions
... - Fault diagnostics with optional load and system monitoring - Energy efficiency with power control solutions CARLO GAVAZZI Automation Components. Specifications are subject to change without notice. Illustrations are for example only. ...
... - Fault diagnostics with optional load and system monitoring - Energy efficiency with power control solutions CARLO GAVAZZI Automation Components. Specifications are subject to change without notice. Illustrations are for example only. ...
DTS 305 - Logic, Inc.
... The DTS 305 operates normally when powered by an externally fused auxiliary supply (fuses rated 2A 300Vac) in the following ranges. (Fuses not included with meter). These ranges are model dependant. See the rating label of the unit for more information. 90 to 265 Vac 50/60 Hz or Vdc 12 Vdc, 24Vdc or ...
... The DTS 305 operates normally when powered by an externally fused auxiliary supply (fuses rated 2A 300Vac) in the following ranges. (Fuses not included with meter). These ranges are model dependant. See the rating label of the unit for more information. 90 to 265 Vac 50/60 Hz or Vdc 12 Vdc, 24Vdc or ...
S280-70-2_10000
... When the phase or ground current exceeds its programmed minimum-trip value and associated time-current-curve (TCC) timing, the control initiates the programmed sequence of recloser tripping and reclosing operations via the CPU and RIF modules. If the fault is temporary, the control resets to the sta ...
... When the phase or ground current exceeds its programmed minimum-trip value and associated time-current-curve (TCC) timing, the control initiates the programmed sequence of recloser tripping and reclosing operations via the CPU and RIF modules. If the fault is temporary, the control resets to the sta ...
IF 1664 Revision 2
... Perform visual, electrical, and mechanical inspections on a regular basis. The environment and frequency of use should determine this. However, it is recommended that checks be made at least once a year. We recommend an Electrical Preventive Maintenance Program as described in the National Fire Prot ...
... Perform visual, electrical, and mechanical inspections on a regular basis. The environment and frequency of use should determine this. However, it is recommended that checks be made at least once a year. We recommend an Electrical Preventive Maintenance Program as described in the National Fire Prot ...
chapter 1 - ePrints USM
... drives, inverters and arc furnaces are mostly common in industrial areas. Increasing numbers of these loads in electrical system for the purpose of, such as improving energy efficiency, has caused an increase in harmonics pollution. These loads draw non-sinusoidal current from the system. The wavefo ...
... drives, inverters and arc furnaces are mostly common in industrial areas. Increasing numbers of these loads in electrical system for the purpose of, such as improving energy efficiency, has caused an increase in harmonics pollution. These loads draw non-sinusoidal current from the system. The wavefo ...
DCS 3kW Series DC Power Supplies
... Installation and service must be performed by qualified personnel who are aware of dealing with attendant hazards. This includes such simple tasks as fuse verification. Ensure that the AC power line ground is connected properly to the DCS Series unit input connector or chassis. Similarly, other powe ...
... Installation and service must be performed by qualified personnel who are aware of dealing with attendant hazards. This includes such simple tasks as fuse verification. Ensure that the AC power line ground is connected properly to the DCS Series unit input connector or chassis. Similarly, other powe ...
AH293 LOW VOLTAGE HALL-EFFECT SMART FAN MOTOR CONTROLLER
... the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance w ...
... the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance w ...
Zero-current zero-voltage transition inverters with
... These inverters are unique in that because they are implemented with a non-resonant auxiliary circuit, Class A AVS [9]. Furthermore, this AVS implementation allows for a set of advantages hitherto only presented for ZVT inverters, such as variable timing control for the auxiliary switches and simple ...
... These inverters are unique in that because they are implemented with a non-resonant auxiliary circuit, Class A AVS [9]. Furthermore, this AVS implementation allows for a set of advantages hitherto only presented for ZVT inverters, such as variable timing control for the auxiliary switches and simple ...
MAX1777/MAX1977/MAX1999 High-Efficiency, Quad Output, Main Power- Supply Controllers for Notebook Computers General Description
... switch-mode power-supply (SMPS) controllers generate logic-supply voltages in battery-powered systems. The MAX1777/MAX1977/MAX1999 include two pulse-width modulation (PWM) controllers, adjustable from 2V to 5.5V or fixed at 5V and 3.3V. These devices feature two linear regulators providing 5V and 3. ...
... switch-mode power-supply (SMPS) controllers generate logic-supply voltages in battery-powered systems. The MAX1777/MAX1977/MAX1999 include two pulse-width modulation (PWM) controllers, adjustable from 2V to 5.5V or fixed at 5V and 3.3V. These devices feature two linear regulators providing 5V and 3. ...
EVOLUTION OF DIGITALLY CONTROLLED OSCILLATORS
... voltage input which is in analog form. This form of oscillators is called voltage controlled oscillator (VCO). VCOs are extensively used in CMOS technology. As the technology of CMOS scaling improves from decade to decade, CMOS process is called deep-submicrometer or down-sizing. CMOS deep-submicrom ...
... voltage input which is in analog form. This form of oscillators is called voltage controlled oscillator (VCO). VCOs are extensively used in CMOS technology. As the technology of CMOS scaling improves from decade to decade, CMOS process is called deep-submicrometer or down-sizing. CMOS deep-submicrom ...
APPLICATION NOTE AN/96031 TDA8790M EVALUATION BOARD DOCUMENTATION
... of the main TDA8790 characteristics. It is realized with a two layer PCB. The following features are included : - One single power supply (+8V +/-10%) is required to generate the supplies needed by the on-board ICs. Connection via banana plugs or grips is possible. To avoid supply connection errors, ...
... of the main TDA8790 characteristics. It is realized with a two layer PCB. The following features are included : - One single power supply (+8V +/-10%) is required to generate the supplies needed by the on-board ICs. Connection via banana plugs or grips is possible. To avoid supply connection errors, ...
Meeting Minutes - Northwest Power and Conservation Council
... This section could point the reader to appropriate resources for estimating the savings that would cost justify the implementation of an automated CVR system (I.e. those in category (b), who cannot use this protocol to justify a future installation of an automated CVR system). Section 3, Definition ...
... This section could point the reader to appropriate resources for estimating the savings that would cost justify the implementation of an automated CVR system (I.e. those in category (b), who cannot use this protocol to justify a future installation of an automated CVR system). Section 3, Definition ...
... Wind Power Facility Technical Requirements Collector Bus means the low voltage side of the transmission systems step-up transformer which is the same as the medium voltage network or aggregate of medium voltage networks that connect to the low-voltage side of the transmission system transformer. Th ...
Low Power Very High Frequency Switch-Mode Power
... When designing power converters it is always a goal to reduce the price and the physical size, i.e. increase the power density. The development of Switch Mode Power Supplies (SMPS) has made it possible to increase the power density significantly, but it is limited by the size of the passive energy s ...
... When designing power converters it is always a goal to reduce the price and the physical size, i.e. increase the power density. The development of Switch Mode Power Supplies (SMPS) has made it possible to increase the power density significantly, but it is limited by the size of the passive energy s ...
BU3087FV
... (If the ICs are not mounted to the printed circuit board, the characteristics of ICs may not be fully demonstrated.) Mount 0.1µF capacitors in the vicinity of the IC Pins between 2Pin_AVDD1, 3Pin_AVSS1, and 5Pin_AVDD2, 6Pin_AVSS2, and 12Pin_VSS, 13Pin_VDD respectively. To obtain accurate frequency, ...
... (If the ICs are not mounted to the printed circuit board, the characteristics of ICs may not be fully demonstrated.) Mount 0.1µF capacitors in the vicinity of the IC Pins between 2Pin_AVDD1, 3Pin_AVSS1, and 5Pin_AVDD2, 6Pin_AVSS2, and 12Pin_VSS, 13Pin_VDD respectively. To obtain accurate frequency, ...
FXLP4555MPX Datasheet
... arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation special, consequential or incidental damages. Buyer is responsible for its products and applications using ON Semiconductor products, including compliance w ...
... arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation special, consequential or incidental damages. Buyer is responsible for its products and applications using ON Semiconductor products, including compliance w ...
Three-phase electric power
Three-phase electric power is a common method of alternating-current electric power generation, transmission, and distribution. It is a type of polyphase system and is the most common method used by electrical grids worldwide to transfer power. It is also used to power large motors and other heavy loads. A three-phase system is usually more economical than an equivalent single-phase or two-phase system at the same line to ground voltage because it uses less conductor material to transmit electrical power.The three-phase system was independently invented by Galileo Ferraris, Mikhail Dolivo-Dobrovolsky, Jonas Wenström and Nikola Tesla in the late 1880s.