• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
flexibile ac transmission system (facts)
flexibile ac transmission system (facts)

... the paper. But the paper is of no use to us. We need it to post the paper. Here the paper is active power and the envelop is the reactive power .Reactive power appears in all electric power systems, due to the laws of nature. Contrary to active power, which is what we really want to transmit over ou ...
Power System Stabilizer Tuning Study
Power System Stabilizer Tuning Study

... ____,____,____ (required data for all round rotor units) Torsional profile showing which sections (i.e. generator, turbines) participate in each torsional frequency Rough zone (gate/MW start/end) (hydro units) _________________________ ...
enter title here (14 pt type size, uppercased, bold and centered over
enter title here (14 pt type size, uppercased, bold and centered over

... current. The converter is operated at several 10kHz leading to a tolerable low output current ripple. The maximum peak current of the output stage operating at European mains condition (e.g. 13A for 2kW output power) can be easily handled by modern power ...
SPS101 DC Sensor Power Supply
SPS101 DC Sensor Power Supply

Document
Document

... voltage source connected in opposite way; to maintan voltage u(t) in branches B, C it is necessary connect another two voltage sources u(t) ...
A.C. LINE VOLTAGE REGULATOR 30 AMP, WORLD WIDE USE
A.C. LINE VOLTAGE REGULATOR 30 AMP, WORLD WIDE USE

... brownouts, or overvoltages that can cause sensitive digital equipment to malfunction, or, in extreme cases, to sustain damage. It accepts single phase input AC voltages anywhere within two capture ranges, 88 to 134 or 170 to 264 Volts, and converts them to the North American standard 120 Volts (or, ...
Willow Glen Short Circuit Study
Willow Glen Short Circuit Study

... power system components, devices, and controls. • Power system components - Generators, excitation systems, over/under excitation limiters, static VAr systems, mechanically switched capacitors, under load tap changing transformers, and loads among others. • Loads are most difficult to model. – Compl ...
Photoresistor and Voltage Divider Objectives The
Photoresistor and Voltage Divider Objectives The

... semiconductor whose resistance decreases with increasing incident light. The principle is that when light of high enough frequency falls on the device, photons absorbed by the semiconductor give bound electrons enough energy to jump into the conduction band. The resulting free electrons conduct elec ...
Cisco TelePresence Server 7010 safety and compliance information
Cisco TelePresence Server 7010 safety and compliance information

AC Power Switch
AC Power Switch

- Status Instruments
- Status Instruments

... undesired path to earth and cause errors. Isolating the temperature transmitter from the monitoring /control equipment such as a PLC or display can help remove this type of problem. This can occur with any type of sensor where some of the loop signal current can find a path to earth. ...
Electrical Traction Sytsem
Electrical Traction Sytsem

Voltage Regulator Placement - WindMil
Voltage Regulator Placement - WindMil

... •  While a regulator will control the voltage at it’s load terminals, the real goal is to maintain good voltage for the customers •  Frequently, we have to locate our regulators away from the areas where we want to adjust and correct voltages •  If one can calculate the electrical distance (Z) betwe ...
Gain Block Active Bias Circuit AN035
Gain Block Active Bias Circuit AN035

... device current as Vd(T). Many customers who utilize our products in battery operated or other low voltage applications find that they do not have a 2 Volt margin to spare. This problem can be addressed by utilizing a high compliance current source. ...
ABB string inverters PVI-10.0-I
ABB string inverters PVI-10.0-I

Negative Feedback
Negative Feedback

... Class A, the plate current of both tubes is flowing uninterrupted over the entire cycle. In ideal class B the plate current is zero when there is no input signal. When the signal appears each tube conducts over half of the cycle. The two tubes work alternately so the whole cycle is amplified. Class ...
Individual-phase decoupled P–Q control of three
Individual-phase decoupled P–Q control of three

Neutral to Earth Voltage Reduction Methods in Three
Neutral to Earth Voltage Reduction Methods in Three

... Generally, distribution networks are operated in an unbalanced configuration and also service to consumers. This fact causes current flowing through neutral conductor and voltage dropping on neutral wire. The unbalance load and excessive current in neutral wire is one of the issues in threephase fou ...
View course syllabus - Cleveland Institute of Electronics
View course syllabus - Cleveland Institute of Electronics

Building Circuits (PHET) - Limestone District School Board
Building Circuits (PHET) - Limestone District School Board

... and black leads so that they touch either side of the part of the resistor you want to measure. Make sure that the voltage reading is positive. If it is negative, you hooked them up backwards and need to switch them. Ammeter – To use the ammeter, again, check the box next to “Ammeter”. This time, th ...
Z35149151
Z35149151

section 262816 - enclosed switches and circuit breakers
section 262816 - enclosed switches and circuit breakers

... Transformer Circuit Fuses: Transformer circuit fuses shall be Class RK1 or RK5, currentlimiting, time-delay with 200,000 amperes interrupting capacity. ...
EE 210
EE 210

instructions to tenderers
instructions to tenderers

Submersible Instruction Manual
Submersible Instruction Manual

... hot stick operable load-break switches can interrupt load and loop current by manual operation. However, they are not circuit breakers which can open automatically on currents above rated load nor are they capable of interrupting fault current. The recommended loop sectionalizing switch arrangement ...
< 1 ... 853 854 855 856 857 858 859 860 861 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report