• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Pspice Slide - Electrical Engineering
Pspice Slide - Electrical Engineering

Mesh Current Method
Mesh Current Method

... Status 10/2/2015 For use at CCUT Fall 2015 ...
Owner`s Manual
Owner`s Manual

... The grounding wire (bare, green or green with yellow stripe and normally non-current carrying) should not be confused with the negative ground wire (black or yellow and normally current carrying). In Boatowner’s Illustrated Handbook of Wiring, Charlie Wing identifies three purposes of DC grounding: ...
Single-Ended “Big Iron” Guitar Amplifier Ray Lyons
Single-Ended “Big Iron” Guitar Amplifier Ray Lyons

... the main circuit. The fiberboard was laid out and soldered outside of the main chassis, and then placed in the chassis as one unit. It would have been extremely difficult to solder all of the connections while working inside the chassis. All of the high voltage leads on the capacitors were wrapped w ...
AN-102A APPLICATION NOTE Interface Circuits for the QD Series
AN-102A APPLICATION NOTE Interface Circuits for the QD Series

... The I/Q outputs can be modeled as voltage sources with 100 Ω of differential source resistance. When a sinewave RF input signal at +3 dBm is demodulated, the resulting I and Q differential output signals are ...
An Improved UPQC Controller to Provide Grid-Voltage
An Improved UPQC Controller to Provide Grid-Voltage

LP2951
LP2951

WORLD-BEAM QS30 Universal Voltage Quick Start Guide
WORLD-BEAM QS30 Universal Voltage Quick Start Guide

... Max. Switching Voltage (resistive load): 250 V ac; 125 V dc Max. Switching Current (resistive load): 5 A at 250 V ac; 5 A at 30 V dc derated to 200 mA at 125 V dc Min. Voltage and Current: 5 V dc, 10 mA Mechanical life of relay: 50 million operations Electrical life of relay at full resistive load: ...
Print this article - International Journal of Innovative Research and
Print this article - International Journal of Innovative Research and

... light or wind, or being installed facing different directions or widely separated locations. Power optimizers for solar applications, can be similar to micro inverters, in that both systems attempt to isolate individual panels in order to improve overall system performance. A microinverter essential ...
power conditions
power conditions

Chapter 24 Electrical Power
Chapter 24 Electrical Power

... powering the electrical system when alternator power is not available (engine not running). The battery also powers the electrical system in case of alternator failure. A rocker type master switch is used for energizing the master relay, which connects power to the electrical system. The master swit ...
Low-current sensing circuit and topology for portable gamma
Low-current sensing circuit and topology for portable gamma

... This design was also verified using simulations, where all the switches were replaced with MOSFETs and the entire circuit is split into 4 blocks. The first block is a voltage reference [6] and other external conversions required for accurate functionality of the entire circuit, which is followed by ...
Tensor Analysis Application to Characterize the Motor of
Tensor Analysis Application to Characterize the Motor of

22721 Demonstrate and apply fundamental knowledge of
22721 Demonstrate and apply fundamental knowledge of

... which are assessing against unit standards must engage with the moderation system that applies to those standards. Requirements for consent to assess and an outline of the moderation system that applies to this standard are outlined in the Consent and Moderation Requirements (CMR). The CMR also incl ...
Document
Document

... • For a 6 pulse converter, this can be easily arranged. The Graetz circuit shown in Fig. is obtained when the two windings are combined into one. • Thus, it is shown that both from valve and transformer utilization considerations. Graetz circuit is the best circuit for a six pulse converter. • In H ...
ICT Modular Power Series_Data Sheet_800-340-000
ICT Modular Power Series_Data Sheet_800-340-000

... The ICT Modular Power Series provides N+1 redundancy with 700 watt hot swappable 12, 24 or 48 volt power modules. The power shelf can accomodate one to four power modules and one or two accessory modules. A dedicated slot holds the optional Intelligent Control Module for full TCP/IP remote monitorin ...
Q-point
Q-point

KST10 NPN Epitaxial Silicon Transistor
KST10 NPN Epitaxial Silicon Transistor

... or (b) support or sustain life, or (c) whose failure to perform when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. ...
KD2004-CG10A
KD2004-CG10A

Protection of Control Circuit Transformers for applications in North
Protection of Control Circuit Transformers for applications in North

Document
Document

... and some other benefits. EXISTING SYSTEM:  Due to the elimination of the full-bridge input rectifier, the components in the current path are reduced and this results in fewer conduction losses.  There are several bridgeless PFC topologies already published, for example the “Basic Bridgeless Boost ...
Simulation of DC-DC Converter-Fed BLDC Motor Drive for PFC
Simulation of DC-DC Converter-Fed BLDC Motor Drive for PFC

... current (BLDC) motor in these applications is becoming very common due to features of high efficiency, high flux density per unit volume, low maintenance requirements, and low electromagnetic-interference problems [1]. These BLDC motors are not limited to household applications, but these are suitab ...
AC Generators
AC Generators

You are required to lead a lab activity with the class
You are required to lead a lab activity with the class

FSL137MRIN ™) Green-Mode Fairchild Power Switch (FPS
FSL137MRIN ™) Green-Mode Fairchild Power Switch (FPS

... an unexpected abnormal event. In this situation, the protection circuit should trigger to protect the SMPS. However, even when the SMPS is in normal operation, the overload protection circuit can be triggered during the load transition. To avoid this undesired operation, the overload protection circ ...
< 1 ... 713 714 715 716 717 718 719 720 721 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report