DCR600-20 - Pacific Power Source
... capability of the AMX Series AC Power Sources, low voltage ripple can be accomplished with only minimal bulk DC storage capacitance at the output. This results in faster DC slew rates compared to a typical 6KW DC Power Supply. No modifications are needed to the AC Power Source to use the DCR unit as ...
... capability of the AMX Series AC Power Sources, low voltage ripple can be accomplished with only minimal bulk DC storage capacitance at the output. This results in faster DC slew rates compared to a typical 6KW DC Power Supply. No modifications are needed to the AC Power Source to use the DCR unit as ...
Product Linecard
... hybrid power for transportation and heavy equipment, grid storage, emergency lighting, UPS bridge power, and a safe, green alternative to batteries. ...
... hybrid power for transportation and heavy equipment, grid storage, emergency lighting, UPS bridge power, and a safe, green alternative to batteries. ...
HI-303/883 Datasheet
... All Intersil U.S. products are manufactured, assembled and tested utilizing ISO9000 quality systems. Intersil Corporation’s quality certifications can be viewed at www.intersil.com/design/quality Intersil products are sold by description only. Intersil Corporation reserves the right to make changes ...
... All Intersil U.S. products are manufactured, assembled and tested utilizing ISO9000 quality systems. Intersil Corporation’s quality certifications can be viewed at www.intersil.com/design/quality Intersil products are sold by description only. Intersil Corporation reserves the right to make changes ...
MP2161 - Monolithic Power System
... capacitors, a small and high quality ceramic capacitor, i.e. 0.1μF, should be placed as close to the IC as possible. When using ceramic capacitors, make sure that they have enough capacitance to provide sufficient charge to prevent excessive voltage ripple at input. The input voltage ripple caused b ...
... capacitors, a small and high quality ceramic capacitor, i.e. 0.1μF, should be placed as close to the IC as possible. When using ceramic capacitors, make sure that they have enough capacitance to provide sufficient charge to prevent excessive voltage ripple at input. The input voltage ripple caused b ...
high-pass
... with Alternating Current Current that varies in amplitude but does not reverse in polarity is considered pulsating or fluctuating direct current. Fig. 26-2 illustrates how a circuit can have pulsating direct current or voltage. The steady dc voltage of the battery VB is in series with the ac v ...
... with Alternating Current Current that varies in amplitude but does not reverse in polarity is considered pulsating or fluctuating direct current. Fig. 26-2 illustrates how a circuit can have pulsating direct current or voltage. The steady dc voltage of the battery VB is in series with the ac v ...
Irradiation tests of voltage limiters
... the voltage at the power supply output will be higher then maximum voltage allowed for ASICs. The absolute maximum for ASICs is 5.5 V while the voltage at power supplies will be higher than 8 V in worst cases. In an event of sudden current drop supply voltage at modules could exceed the maximum allo ...
... the voltage at the power supply output will be higher then maximum voltage allowed for ASICs. The absolute maximum for ASICs is 5.5 V while the voltage at power supplies will be higher than 8 V in worst cases. In an event of sudden current drop supply voltage at modules could exceed the maximum allo ...
BX Miniature Spark Gaps Description and Use Application Note
... has been designed for applications that have severe environment and high reliability requirements. The BX Series is made with high alumina (Al2O3) ceramic and metal electrodes that are hermetically sealed at high braze temperatures to withstand extreme levels of temperature and rugged environmental ...
... has been designed for applications that have severe environment and high reliability requirements. The BX Series is made with high alumina (Al2O3) ceramic and metal electrodes that are hermetically sealed at high braze temperatures to withstand extreme levels of temperature and rugged environmental ...
SN_presentation_General_Nov_10_2009 - Indico
... inductance. This is not neccesary when running pulses >>10 us NEXT ...
... inductance. This is not neccesary when running pulses >>10 us NEXT ...
12 - Research Script International Journals
... A new soft-switching boost converter with an auxiliary switch and resonant circuit is planned in this paper. The resonant circuit consists of a resonant inductor, two resonant capacitors, two diodes, and an auxiliary switch. The resonant capacitor is discharged beforehand the main switch is turned O ...
... A new soft-switching boost converter with an auxiliary switch and resonant circuit is planned in this paper. The resonant circuit consists of a resonant inductor, two resonant capacitors, two diodes, and an auxiliary switch. The resonant capacitor is discharged beforehand the main switch is turned O ...
How to select external components for DC/DC Converters
... e. For the step-up DC/DC converters, please choose a MOSFET with a rated current two or three times more than the peak current. For the step-down DC/DC converters, a rated current around two times of the output current multiply by step-down ratio should be selected. Please check the current waveform ...
... e. For the step-up DC/DC converters, please choose a MOSFET with a rated current two or three times more than the peak current. For the step-down DC/DC converters, a rated current around two times of the output current multiply by step-down ratio should be selected. Please check the current waveform ...
style guidelines to assist authors preparing papers using ms word
... The proportionality in the above equation accounts for the power factor of the rotor circuit as well as for and for rotor losses. Together, these two factors account for less than 5%. The machines on this SAG mill are rated 3 600 kW with nominal rotor data of 2 608 Volts and 836 Amps. Therefore, in ...
... The proportionality in the above equation accounts for the power factor of the rotor circuit as well as for and for rotor losses. Together, these two factors account for less than 5%. The machines on this SAG mill are rated 3 600 kW with nominal rotor data of 2 608 Volts and 836 Amps. Therefore, in ...
Evaluates: MAX1711 MAX1711 Voltage Positioning Evaluation Kit General Description Features
... If the DAC inputs (D0–D4) are changed, the output voltage will change accordingly. However, under some circumstances, the output voltage transition may be slower than desired. All transitions to a higher voltage will occur very quickly, with the circuit operating at the current limit set by the volt ...
... If the DAC inputs (D0–D4) are changed, the output voltage will change accordingly. However, under some circumstances, the output voltage transition may be slower than desired. All transitions to a higher voltage will occur very quickly, with the circuit operating at the current limit set by the volt ...
Quantum Hall Effect Manual
... the coil with a superconducting shunt, any current present in the coil will circulate indefinitely, thus maintaining an extremely stable, perpetual magnetic field. However, the inclusion of this superconducting shunt creates a problem: any current we attempt to put through the coil will simply trave ...
... the coil with a superconducting shunt, any current present in the coil will circulate indefinitely, thus maintaining an extremely stable, perpetual magnetic field. However, the inclusion of this superconducting shunt creates a problem: any current we attempt to put through the coil will simply trave ...
MAX8535EVKIT
... input that sets the charge-pump frequency or functions as a logic enabler. The MAX8535 EV kit circuit provides a 3-pin jumper (JU1) to configure the TIMER pin. Place a shunt across pins 2 and 3 of JU1 to shutdown the MAX8535. Place a shunt across pins 1 and 2 of JU1 to connect the TIMER pin to groun ...
... input that sets the charge-pump frequency or functions as a logic enabler. The MAX8535 EV kit circuit provides a 3-pin jumper (JU1) to configure the TIMER pin. Place a shunt across pins 2 and 3 of JU1 to shutdown the MAX8535. Place a shunt across pins 1 and 2 of JU1 to connect the TIMER pin to groun ...
STANDARD REVIEW PLAN U.S. NUCLEAR REGULATORY COMMISSION
... Phase C condition and manually tripped breakers to separate the unit buses from the offsite power source. When the operators opened the SAT feeder breakers to the two 4.16-kV ESF buses, the loss of ESF bus voltage resulted in the emergency diesel generators (EDGs) automatically starting and restorin ...
... Phase C condition and manually tripped breakers to separate the unit buses from the offsite power source. When the operators opened the SAT feeder breakers to the two 4.16-kV ESF buses, the loss of ESF bus voltage resulted in the emergency diesel generators (EDGs) automatically starting and restorin ...
AND8236/D
... ON Semiconductor and are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any partic ...
... ON Semiconductor and are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any partic ...
BM1Q0XX series Quasi-Resonant converter Technical Design
... Set 400V or above with design margin. (4) Determination of D3 Choose a fast recovery diode as the diode, with a withstanding voltage that is at or above the MOSFET’s Vds (max) value. The surge-voltage affects not only the transformer’s leakage inductance but also the PCB substrate’s pattern. Confirm ...
... Set 400V or above with design margin. (4) Determination of D3 Choose a fast recovery diode as the diode, with a withstanding voltage that is at or above the MOSFET’s Vds (max) value. The surge-voltage affects not only the transformer’s leakage inductance but also the PCB substrate’s pattern. Confirm ...
Digital High Voltage Insulation Tester KEW 3128
... switches, insulators, wiring installations, etc. ...
... switches, insulators, wiring installations, etc. ...
Electrical substation
A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.