• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
A Novel Power Factor Control Scheme For High
A Novel Power Factor Control Scheme For High

... The proposed control scheme can also produce a unity power factor when the converter operates in a regeneration mode. The regeneration occurs when the dc voltage changes its polarity. For example, in an induction motor drive where the GTO converter is used as a front-end converter, the dc voltage wi ...
AP8803 Description Pin Assignments
AP8803 Description Pin Assignments

... This rising current produces a voltage ramp across RSET. The internal circuit of the AP8803 senses the voltage across RSET and applies a proportional voltage to the input of the internal comparator. When this voltage reaches an internally set upper threshold, the internal switch is turned off. The i ...
Transistors
Transistors

Experiment 8
Experiment 8

Design of High Performance Arithmetic and Logic
Design of High Performance Arithmetic and Logic

Electrical Safety
Electrical Safety

... The wire has a quite low melting point. As current flows through the wire it heats up. If too large a current flows it melts, thus breaking the circuit Use appropriate fuse size/rating ...
5. Diodes As with transistors, diodes are fabricated from semi
5. Diodes As with transistors, diodes are fabricated from semi

AND8230/D Application Hints for Transient Voltage Suppression Diode Circuits
AND8230/D Application Hints for Transient Voltage Suppression Diode Circuits

Advanced Computer Architecture
Advanced Computer Architecture

10ppm/°C, 1μA, 1.25V Shunt Voltage Reference
10ppm/°C, 1μA, 1.25V Shunt Voltage Reference

... Typical connections for the REF1112 are shown in Figure 1. A minimum 1µA bias current is required to maintain a stable output voltage and can be provided with a resistor connected to the supply voltage. IBIAS depends on the values selected for RBIAS and VS, and will vary as a sum of the minimum oper ...
A Novel Approach of Position Estimation, PFC based Buck
A Novel Approach of Position Estimation, PFC based Buck

... than one, they have to supply more current to the user for a given amount of power use. In so doing, they incur more line losses. They also must have larger capacity equipment in place than would be otherwise necessary. As a result, an industrial facility will be charged a penalty if its power facto ...
Operating FAC-010-AB1-2.1 Alberta Reliability Standard
Operating FAC-010-AB1-2.1 Alberta Reliability Standard

... The following measures correspond to the requirements identified in Section 3 of this reliability standard. For example, MR1 is the measure for R1. MR1 Evidence of having a documented system operating limit methodology as required in requirement R1 exists. MR2 Evidence of the system operating limit ...
AS1360
AS1360

... austriamicrosystems AG makes no warranty, express, statutory, implied, or by description regarding the information set forth herein or regarding the freedom of the described devices from patent infringement. austriamicrosystems AG reserves the right to change specifications and prices at any time an ...
Designstudie av framtida 10kW växelriktare Daniel Eidborn
Designstudie av framtida 10kW växelriktare Daniel Eidborn

... matters of primary interest to assess are power density, efficiency, reliability, cooling needs and cost. This work concentrates on a 10 kW inverter intended for a general motor supply. The power supply is a 400 Hz, 230 VPh three phases or a ± 270 V DC source. Other power levels than 10 kW are also ...
ECEN5817L38
ECEN5817L38

RA07H3340M 数据资料DataSheet下载
RA07H3340M 数据资料DataSheet下载

thyristors and triacs control gate trigger circuits
thyristors and triacs control gate trigger circuits

... using specialized integrated circuits (eg. UAA145). The trigger control circuits manufacturing without dedicated integrated circuits can be justified today only for simple applications, such as the structures with a single low power thyristor or triac. Choosing a trigger control circuit with discret ...
Advanced Cascade Multilevel Converter with Reduction in Number
Advanced Cascade Multilevel Converter with Reduction in Number

Power Electronics
Power Electronics

... The resulting current in ,the inductor resists the change but does rise! • An inductor resists changes in current. • An ideal inductor would offer no resistance to direct current; however, all real-world inductors have non-zero electrical resistance. ...
Power Distribution in Data Centers
Power Distribution in Data Centers

LX Owner`s Manual
LX Owner`s Manual

... irrigation spray and central to where the majority of the lighting fixtures will be installed. The goal is to minimize the length of cable runs from your transformer to the lighting fixtures thus minimizing voltage drop and cable size. Transformer(s) with power cords must be located adjacent to a 12 ...
— mWSaver™ PWM Controller FAN6757 FAN 6
— mWSaver™ PWM Controller FAN6757 FAN 6

... High-Voltage Startup. This pin is connected to the line input or bulk capacitor, via 200 kΩ resistors, to achieve brownout and high/low line compensation. If the voltage of the HV pin is lower than the brownout voltage (AC line peak voltage less than 100 V) and lasts for 65 ms, PWM output turns off. ...
MC1408−8 8−bit Multiplying D/A Converter
MC1408−8 8−bit Multiplying D/A Converter

... zero−scale current has been nulled out. The relative accuracy of the MC1408−8 is essentially constant over the operating temperature range because of the excellent temperature tracking of the monolithic resistor ladder. The reference current may drift with temperature, causing a change in the absolu ...
Aid troubleshooting
Aid troubleshooting

... If the LED immediately lights again (either before the engine is started or immediately afterward), the alternator is eliminated as the culprit since it is disconnected and the field lead itself is suspect. Shut down the system and remove the field wire from the harness side of the voltage regulator ...
Is Only Full SiC the "Real" SiC?
Is Only Full SiC the "Real" SiC?

... in power output. Therefore, the overall SRZHUGHQVLW\LVVLJQL¿FDQWO\LQFUHDVHG This means that when SiC components are used in applications that UHTXLUHPDJQHWLFVIRURXWSXWYROWDJH¿OWHULQJVXFKDVVRODULQYHUWHUVRU836V\VWHPVWKHEHQH¿WVFDQEHHQRUPRXV%\LQFUHDVLQJ the switching frequen ...
< 1 ... 526 527 528 529 530 531 532 533 534 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report