• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
III. MoDeling of proposed Topology
III. MoDeling of proposed Topology

... D.C voltages, typically obtained from capacitor voltage sources. As the number of levels increases, the synthesized output waveform has more steps, which produces a stair-case wave that approaches a desired waveform. Also, as more steps are added to the waveform, the harmonic distortion of the outpu ...
UM0933
UM0933

... The STEVAL- ISW001V1 is a 2.5 kW welding machine capable of 135 A of welding current. It is designed for small industrial applications and domestic use in many DIY applications. The machine is ready-to-use and designed to implement the Manual Metal Arc (MMA) welding process and to weld iron and stee ...
Methods of excitation Separately Excited DC Generator These are
Methods of excitation Separately Excited DC Generator These are

... (say) Then, voltage across the load, V = IRa Power generated, Pg = Eg×I Power delivered to the external load, PL = V×I. Self-excited DC Generators These are the generators whose field magnets are energized by the current supplied by themselves. In these type of machines field coils are internally co ...
Power Distribution Control Coordinating Ultracapacitors and
Power Distribution Control Coordinating Ultracapacitors and

Solution
Solution

... the load; and then if the switch is opened for time t2 the current continues to flow through the inductor and the diode” closed path’. If there in no closed path the inductive energy induces a very high voltage and this energy is dissipated in form of heat and spark. The diode realized closed path i ...
View Attachment - Northeast Power Coordinating Council, Inc.
View Attachment - Northeast Power Coordinating Council, Inc.

... disturbance data is available to facilitate analysis of bulk power system (BPS) disturbances. All references to equipment and facilities herein, unless otherwise noted, will be to BPS elements. ...
AM34232235
AM34232235

... angle control of converter design. The thyristor of converter receive conduction the firing pulse either mode of continuous or discontinuous operation. To simplify single phase dual converter, two of these full converter are connected back to back as shown in figure 2. The system will provide four q ...
F2322/01 - Modena/Strato Universal Dimmer 8000 Series
F2322/01 - Modena/Strato Universal Dimmer 8000 Series

... The Clipsal 8000 Series Universal Dimmer is a separately switched, compact, modular dimming mechanism rated at 450W, and designed for universal load compatibility. The unit utilises powerful and sophisticated dimming technology to provide full control of almost any type of load, whether it be incand ...
STC03DE220HV
STC03DE220HV

... 27-Nov-2006 ...
Steady-State and Transient Currents in Organic
Steady-State and Transient Currents in Organic

... as the injection current is reduced, the transit time (time of the peak current) is increased; the current pulse for the highest injection level resembles those obtained by Many et al. l ,2; finally, the current at the 2 sec time (the shortest time we can reliably determine the current in these meas ...
High SCCR Overcurrent Protective Devices
High SCCR Overcurrent Protective Devices

... Weak Links and Improving SCCR The following table highlights the weak links encountered in the example on the previous page and provides Cooper Bussmann solutions, along with the added benefits that these solutions can provide for a design. This is an example of how Cooper Bussmann ...
26 20 00 Low Voltage Electrical Transmission
26 20 00 Low Voltage Electrical Transmission

... Switchgear shall be dead-front construction, hinged double doors with stops, rated 600 volts and shall operate on a 480/277 or 208/120 volt, three-phase, solidly grounded wye, 60 Hz system. The switchboard shall be designed in accordance with the latest NEMA, ANSI, and IEEE standards applicable to t ...
bachelor`s degree in electrical engineering technology
bachelor`s degree in electrical engineering technology

... Upon completing this subject, the student should be able to: 1. describe first order for RL and RC circuits transient analysis. 2. describe second order for RLC circuits transient analysis. 3. convert time domain into s-domain using Laplace transforms method and analyze its frequency response. 4. co ...
12V 24V LED Dimmers DIM11, DIM12, DIM13, DIM14
12V 24V LED Dimmers DIM11, DIM12, DIM13, DIM14

... The DIM11, DIM12, DIM13 and DIM14 are self-contained highside dimmer modules designed to control the brightness of lowvoltage incandescent (filament), halogen or LED lamps rated up to 10A. Operating from 9 to 32V DC, and offering a positive output, the modules can be used in a wide variety of applic ...
CS5101AN/D Secondary Side Post Regulator (SSPR) for
CS5101AN/D Secondary Side Post Regulator (SSPR) for

... Drain Resistor A small current is needed to keep the output stage in a low impedance state during abnormal or shutdown conditions. Drain pin current should be checked at the extremes of the supply voltage. ...
Aalborg Universitet EHV/HV Underground Cable Systems for Power Transmission Bak, Claus Leth
Aalborg Universitet EHV/HV Underground Cable Systems for Power Transmission Bak, Claus Leth

... Hammer Bakker  December 2014.  ...
EEE412 Antennas and Propagation
EEE412 Antennas and Propagation

International Electrical Engineering Journal (IEEJ) Vol. 6 (2015) No.2, pp. 1787-1791
International Electrical Engineering Journal (IEEJ) Vol. 6 (2015) No.2, pp. 1787-1791

... the collapse, and so on. Chaos movement studies have identified in the DC-DC converters, most of them because of bifurcation and chaos caused in the system [2]. In most practical situations, required stable operation is a period-1 operation. The interaction of non-linear components with certain rang ...
Local Technical - Florida Building Code
Local Technical - Florida Building Code

Waveform Relaxation Techniques for Simulation of Coupled
Waveform Relaxation Techniques for Simulation of Coupled

... Similarly, performing the convolution in (23) is equivalent to including a parallel combination of current controlled current sources in the circuit netlist, where the controlling curare obtained directly from the previous iterarents tion, and the proportionality factors are given in (24). Note that ...
A Simple Control Scheme for Single
A Simple Control Scheme for Single

... The A.C. to A.C. power converters, in which ac power at one frequency is directly converted to ac power at another frequency, constitute converter-inverter modules for which Matrix converter is the alternative topology as it is more reliable and efficient for A.C. to A.C. power conversion without an ...
Fronius Primo Datasheet
Fronius Primo Datasheet

FrM05.4
FrM05.4

... the ultra-capacitor storage system were examined in both an electric and hybrid electric mass transit vehicle. These simulations were validated with experimental data taken from both an electric transit bus (without an ultra-capacitor energy storage system), provided by the Chattanooga Area Regional ...
Techniques for Energy-Efficient Communication Pipeline Design Gang Qu and Miodrag Potkonjak
Techniques for Energy-Efficient Communication Pipeline Design Gang Qu and Miodrag Potkonjak

... niques. In particular, within the former domain fragmentation techniques for managing congestion control, packet buffering, packet losses, and the optimization techniques for improvement of distributed file systems and high-speed local networks are directly relevant. Within the latter, we focus our ...
6-12 amp, -48 VDC Power System with 6 amp Rectifiers
6-12 amp, -48 VDC Power System with 6 amp Rectifiers

... preset value, the rectifier circuit card will shut down. If two or more rectifier circuit cards are operating in parallel, only the malfunctioning card is shut down. Output Distribution Fuses: Each output (F1-F8) fused at 0 to 4 amps with GMT Type fuses. Total current of the DC outputs must not exce ...
< 1 ... 519 520 521 522 523 524 525 526 527 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report