LP2998/LP2998-Q1 DDR Termination
... however, is used exclusively to provide the rail voltage for the output stage used to create VTT. These pins have the capability to work off separate supplies depending on the application. Higher voltages on PVIN will increase the maximum continuous output current because of output RDSON limitations ...
... however, is used exclusively to provide the rail voltage for the output stage used to create VTT. These pins have the capability to work off separate supplies depending on the application. Higher voltages on PVIN will increase the maximum continuous output current because of output RDSON limitations ...
powercut-1250 / 1500
... body. Use the correct welding screen and filter lens and wear protective The operator must ensure that: clothing. person stationed within the working area of the equipment when it is started up. - no unauthorized S Protect bystanders with suitable screens or curtains. - no one is unprotected when th ...
... body. Use the correct welding screen and filter lens and wear protective The operator must ensure that: clothing. person stationed within the working area of the equipment when it is started up. - no unauthorized S Protect bystanders with suitable screens or curtains. - no one is unprotected when th ...
The American University in Cairo School of Science and Engineering SYNTHESIZABLE
... inductors and transformers, semiconductor devices operated in the linear mode ...
... inductors and transformers, semiconductor devices operated in the linear mode ...
Non-iterative algorithm of analytical synchronization of two
... fault location procedure without need of knowledge of line parameters, assuming synchronization problem is solved. Obvious next step is to develop a fault location algorithm without requirement of synchronization and line parameters setting. Short lines unsymmetrical faults have been covered by meth ...
... fault location procedure without need of knowledge of line parameters, assuming synchronization problem is solved. Obvious next step is to develop a fault location algorithm without requirement of synchronization and line parameters setting. Short lines unsymmetrical faults have been covered by meth ...
IF 1546 Revision 1
... may generate dangerous voltages. Although CHCA has incorporated every practical safety precaution, exercise extreme caution at all times when you expose circuits and components, and when you operate, maintain, or service this equipment. ...
... may generate dangerous voltages. Although CHCA has incorporated every practical safety precaution, exercise extreme caution at all times when you expose circuits and components, and when you operate, maintain, or service this equipment. ...
Chapter 8 Prototype - DTUsat-1
... The primary function of the electronics is to provide the necessary bias voltage for the emitter. As the tether is being used in the current generating configuration, this voltage could actually be provided by the tether – had it been long enough. This however is dependent on the configuration. In p ...
... The primary function of the electronics is to provide the necessary bias voltage for the emitter. As the tether is being used in the current generating configuration, this voltage could actually be provided by the tether – had it been long enough. This however is dependent on the configuration. In p ...
UWE Series - power, Murata
... open drain transistor. But it may also be driven with external logic or by applying appropriate external voltages which are referenced to Input Common. 6 Short circuit shutdown begins when the output voltage degrades approximately 2% from the selected setting. 7 The outputs are not intended to sink ...
... open drain transistor. But it may also be driven with external logic or by applying appropriate external voltages which are referenced to Input Common. 6 Short circuit shutdown begins when the output voltage degrades approximately 2% from the selected setting. 7 The outputs are not intended to sink ...
Manufacturer Specifications – What do they Mean
... Most MTE specifications describe the performance characteristics covered by the manufacturer’s product warranty. These reported specifications also often include qualifications, clarifications and/or caveats. Therefore, it is a good practice to read all notes and footnotes carefully to determine whi ...
... Most MTE specifications describe the performance characteristics covered by the manufacturer’s product warranty. These reported specifications also often include qualifications, clarifications and/or caveats. Therefore, it is a good practice to read all notes and footnotes carefully to determine whi ...
Old Company Name in Catalogs and Other Documents
... Computers; office equipment; communications equipment; test and measurement equipment; audio and visual equipment; home electronic appliances; machine tools; personal electronic equipment; and industrial robots. “High Quality”: Transportation equipment (automobiles, trains, ships, etc.); traffic con ...
... Computers; office equipment; communications equipment; test and measurement equipment; audio and visual equipment; home electronic appliances; machine tools; personal electronic equipment; and industrial robots. “High Quality”: Transportation equipment (automobiles, trains, ships, etc.); traffic con ...
750kVA SG Series UPS with eBoost Technology
... retransferring the load back to the inverter after the inverter has returned to normal conditions. Retransfer shall not occur if the two sources are not synchronized. The static bypass switch control circuit shall have the ability to lock the critical load to either the inverter output or the bypass ...
... retransferring the load back to the inverter after the inverter has returned to normal conditions. Retransfer shall not occur if the two sources are not synchronized. The static bypass switch control circuit shall have the ability to lock the critical load to either the inverter output or the bypass ...
ACS 200 Frequency Converters for Speed Control of 0.55 to 4.0 kW
... on page 16. Failure to check voltages could cause death or serious injury. Only a competent electrician should carry out the electrical installation. Note! Static voltage can damage electronic circuits. Avoid touching any of the components within the ACS 200. Note! The motor rotational direction can ...
... on page 16. Failure to check voltages could cause death or serious injury. Only a competent electrician should carry out the electrical installation. Note! Static voltage can damage electronic circuits. Avoid touching any of the components within the ACS 200. Note! The motor rotational direction can ...
EFFICIENT CONTROL OF THE SERIES RESONANT CONVERTER FOR HIGH FREQUENCY OPERATION
... operating at high switching frequency. Resonant gate drivers with continuous inductor current experience excessive conduction loss, while discontinuous current drivers are subject to slow transitions and high peak current. Current source drivers suffer from high component count and increased conduct ...
... operating at high switching frequency. Resonant gate drivers with continuous inductor current experience excessive conduction loss, while discontinuous current drivers are subject to slow transitions and high peak current. Current source drivers suffer from high component count and increased conduct ...
FZT853 Features Mechanical Data
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
EntelliGuard G Circuit Breaker Application Guide
... Cable Interlocks (OEM Applications Only) ..........................................................................................................................................................................8 Bell Alarm Contact .................................................................... ...
... Cable Interlocks (OEM Applications Only) ..........................................................................................................................................................................8 Bell Alarm Contact .................................................................... ...
Negotiated Customer Connection Contract
... The Customer must ensure that: 4.1.1 the electrical plant in its facility complies with the relevant Australian Standards as applicable at the time of first installation of that electrical plant in the facility; 4.1.2 circuit breakers provided to isolate the Customer’s facilities from Energex’s faci ...
... The Customer must ensure that: 4.1.1 the electrical plant in its facility complies with the relevant Australian Standards as applicable at the time of first installation of that electrical plant in the facility; 4.1.2 circuit breakers provided to isolate the Customer’s facilities from Energex’s faci ...
ZX5T851G Features Mechanical Data
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
S280-70-1
... A functional block diagram of the Form 6 recloser control is shown in Figure 2. Line current flowing through the recloser is converted by the CPU module to a digital signal suitable for metering and fault current calculations. Data sampling occurs at a rate of 64 times per cycle. The CPU contains a ...
... A functional block diagram of the Form 6 recloser control is shown in Figure 2. Line current flowing through the recloser is converted by the CPU module to a digital signal suitable for metering and fault current calculations. Data sampling occurs at a rate of 64 times per cycle. The CPU contains a ...
Form Factors, Power Supplies, and Working Inside a Computer
... power supply was near the back. If you have a desktop case designed to lie flat, don’t place it on its end because the CD or DVD drive might not work properly. Desktop cases are built to accommodate all form factors for personal computers. Because of the space a desktop case takes, it has fallen out ...
... power supply was near the back. If you have a desktop case designed to lie flat, don’t place it on its end because the CD or DVD drive might not work properly. Desktop cases are built to accommodate all form factors for personal computers. Because of the space a desktop case takes, it has fallen out ...
EP Convection Air Heaters Hazardous Locations
... When making electrical connections to the heater, be sure to follow the wiring diagram provided with the heater. The heater must not be operated without the safety high temperature limit cutout properly connected in the circuit. 1.) All 3 phase heaters and all single phase heaters above 277 volts or ...
... When making electrical connections to the heater, be sure to follow the wiring diagram provided with the heater. The heater must not be operated without the safety high temperature limit cutout properly connected in the circuit. 1.) All 3 phase heaters and all single phase heaters above 277 volts or ...
Electrical substation
A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.