VLT Series 2000/3000 Watt True Sine Wave Inverter
... light display. The Status led should be green indicating the inverter is ready to deliver AC power to the loads. If multiple AC loads will be operated at the same time it may be necessary to turn the loads ON one-at-a-time to prevent inverter overload due to the initial surge required to start the l ...
... light display. The Status led should be green indicating the inverter is ready to deliver AC power to the loads. If multiple AC loads will be operated at the same time it may be necessary to turn the loads ON one-at-a-time to prevent inverter overload due to the initial surge required to start the l ...
LTM8047 - 3.1VIN to 32VIN Isolated uModule DC/DC Converter
... voltage overshoot by applying a capacitor from SS to GND. When the LTM8047 is enabled, whether from VIN reaching a sufficiently high voltage or RUN being pulled high, the LTM8047 will source approximately 10µA out of the SS pin. As this current gradually charges the capacitor from SS to GND, the LTM ...
... voltage overshoot by applying a capacitor from SS to GND. When the LTM8047 is enabled, whether from VIN reaching a sufficiently high voltage or RUN being pulled high, the LTM8047 will source approximately 10µA out of the SS pin. As this current gradually charges the capacitor from SS to GND, the LTM ...
LAMPIRAN A FOTO WIRELESS SERVICE BELL
... Note: These are stress ratings only. Stresses exceeding the range specified under ²Absolute Maximum Ratings² may cause substantial damage to the device. Functional operation of this device at other conditions beyond those listed in the specification is not implied and prolonged exposure to extreme c ...
... Note: These are stress ratings only. Stresses exceeding the range specified under ²Absolute Maximum Ratings² may cause substantial damage to the device. Functional operation of this device at other conditions beyond those listed in the specification is not implied and prolonged exposure to extreme c ...
Smart-UPS UPS Operation Manual
... If the normally closed (NC) EPO configuration is used, the EPO switch or relay should be rated for “dry” circuit applications, the rating should be for low voltage and low current applications. This normally implies the contacts are gold-plated. The EPO interface is a Safety Extra Low Voltage (SELV) ...
... If the normally closed (NC) EPO configuration is used, the EPO switch or relay should be rated for “dry” circuit applications, the rating should be for low voltage and low current applications. This normally implies the contacts are gold-plated. The EPO interface is a Safety Extra Low Voltage (SELV) ...
ZXTP720MA Features and Benefits Mechanical Data
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
XBO R 300 W/60 C
... Therefore, spent (end-of-life) lamps should ALWAYS be stored in the protective covers and packaging in which they originally came, and ultimately de-pressurized before release for disposal. The following is one example of a depressurizing method for XBO lamps prior to disposal, but it may not be the ...
... Therefore, spent (end-of-life) lamps should ALWAYS be stored in the protective covers and packaging in which they originally came, and ultimately de-pressurized before release for disposal. The following is one example of a depressurizing method for XBO lamps prior to disposal, but it may not be the ...
FMMT558 Features Mechanical Data
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
LTM4603HV - 6A, 28VIN DC/DC uModule with PLL, Output Tracking and Margining
... The LTM®4603HV is a complete 6A step-down switch mode DC/DC power supply with onboard switching controller, MOSFETs, inductor and all support components. The μModuleTM is housed in a small surface mount 15mm × 15mm × 2.8mm LGA package. Operating over an input voltage range of 4.5 to 28V, the LTM4603 ...
... The LTM®4603HV is a complete 6A step-down switch mode DC/DC power supply with onboard switching controller, MOSFETs, inductor and all support components. The μModuleTM is housed in a small surface mount 15mm × 15mm × 2.8mm LGA package. Operating over an input voltage range of 4.5 to 28V, the LTM4603 ...
LTC3541-3
... voltage to the buck is less than the reference voltage. The current into the inductor provided to the load increases until the current limit is reached. Once the current limit is reached the main switch turns off and the energy stored in the inductor flows through the bottom synchronous switch into ...
... voltage to the buck is less than the reference voltage. The current into the inductor provided to the load increases until the current limit is reached. Once the current limit is reached the main switch turns off and the energy stored in the inductor flows through the bottom synchronous switch into ...
iQ Series Ultrasonic Generator/Power Supply Auto-Plus
... Line Voltage Regulation automatically maintains constant amplitude regardless of line voltage deviation. The available output power is maintained with any voltage input within the specified range. This provides consistent system performance regardless of line voltage fluctuations. It also eliminates ...
... Line Voltage Regulation automatically maintains constant amplitude regardless of line voltage deviation. The available output power is maintained with any voltage input within the specified range. This provides consistent system performance regardless of line voltage fluctuations. It also eliminates ...
ZXTN10150DZ
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
ZXTP718MA Features and Benefits Mechanical Data
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
Basic Electronics Competency Requirements
... Identify common types of transformers and explain step-up/step-down in relation to turns ratio ...
... Identify common types of transformers and explain step-up/step-down in relation to turns ratio ...
Galaxy 5000/Galaxy 5500 40–130 kVA 480 V, 20–120 kVA
... This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment ge ...
... This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment ge ...
M4315-PRO Instructions
... M4315-PRO is designed to eliminate these transients by providing a “start-up” delay for the High-Current outlets and a “shut-down” delay for the Switched Outlet Banks. This minimizes inrush current issues by allowing the components plugged into the Switched Outlet Banks to power-up and stabilize bef ...
... M4315-PRO is designed to eliminate these transients by providing a “start-up” delay for the High-Current outlets and a “shut-down” delay for the Switched Outlet Banks. This minimizes inrush current issues by allowing the components plugged into the Switched Outlet Banks to power-up and stabilize bef ...
SJ200/L200 Series - Hitachi America, Ltd.
... are removable from the circuit board to make testing or service more convenient. Note that the relay output connector is not removable, as it must carry higher currents and provide high integrity for alarm conditions. The alarm circuit may carry hazardous live voltages even when the main power to th ...
... are removable from the circuit board to make testing or service more convenient. Note that the relay output connector is not removable, as it must carry higher currents and provide high integrity for alarm conditions. The alarm circuit may carry hazardous live voltages even when the main power to th ...
Model 9005-A - HI
... 2.38 Do not use the meter if it has undergone long-term storage under unfavorable conditions. Failure to observe this precaution may result in damage to the meter or injury to the user. 2.39 Do not use the meter if it may have been damaged in transport. Failure to observe this precaution may result ...
... 2.38 Do not use the meter if it has undergone long-term storage under unfavorable conditions. Failure to observe this precaution may result in damage to the meter or injury to the user. 2.39 Do not use the meter if it may have been damaged in transport. Failure to observe this precaution may result ...
Applied Superconductivity - Walther Meißner Institut
... Other Detectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 328 ...
... Other Detectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 328 ...
HC AC GENERATORS Installation, Servicing, and Maintenance
... · connections to power factor and droop accessories for sharing reactive load in parallel with other generators or mains utility. AVR specification, installation and adjustment information is available in the AVR manual supplied with the generator, or at www.cumminsgeneratortechnologies.com ...
... · connections to power factor and droop accessories for sharing reactive load in parallel with other generators or mains utility. AVR specification, installation and adjustment information is available in the AVR manual supplied with the generator, or at www.cumminsgeneratortechnologies.com ...
Manufacturer of UL Listed Products
... product in VA, because the power factor must also be specified. The inverter can maintain a spectrally pure output with any load, due to a specially designed non-linear control loop in the primary DC to DC converter. This circuitry is one of three circuits which ...
... product in VA, because the power factor must also be specified. The inverter can maintain a spectrally pure output with any load, due to a specially designed non-linear control loop in the primary DC to DC converter. This circuitry is one of three circuits which ...
Electrical substation
A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.