• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
BD45241G
BD45241G

... *This data is for reference only. The figures will vary with the application, so please confirm actual operating conditions before use. Timing Waveform Example: The following shows the relationship between the input voltages VDD, the output voltage VOUT and ER terminal when the input power supply vo ...
TransGuard® Application Notes
TransGuard® Application Notes

... incurring significant additional manufacturing costs. Additionally, the shielding will likely have seams, ventilation holes, or I/O ports which represent a significant portion of a wavelength (at 5 GHz). Therefore, E fields and corona generated RF can be a problem. Finally, if the system has I/O con ...
Rapid Wireless Capacitor Charging Using a Multi
Rapid Wireless Capacitor Charging Using a Multi

HGTG30N60A4D 600V, SMPS Series N
HGTG30N60A4D 600V, SMPS Series N

... 1. Prior to assembly into a circuit, all leads should be kept shorted together either by the use of metal shorting springs or by the insertion into conductive material such as “ECCOSORBD™ LD26” or equivalent. 2. When devices are removed by hand from their carriers, the hand being used should be grou ...
DXR-65 inst_1.eps
DXR-65 inst_1.eps

... National Electric Code (NEC) and connect to the yellow and violet leads coming out of the unit. (CAUTION: The minimum wire size required by the NEC is 12 gauge Copper or equivalent. Your installation may require larger sized wire to ensure that the voltage drop DOES NOT exceed 5%. Do not exceed the ...
MAX5923 +60V Simple Swapper Hot-Swap Switch General Description Features
MAX5923 +60V Simple Swapper Hot-Swap Switch General Description Features

... The MAX5923 provides an Enable input to enable/disable the device with a logic signal and logic output POK that indicates when the output voltage has reached within 750mV of the input voltage. Three fault conditions are monitored: a zero-current condition, an overcurrent condition, and a thermal ove ...
VStack Manual Description
VStack Manual Description

PowerFlex 755T Drive Solutions Low Harmonic Regenerative
PowerFlex 755T Drive Solutions Low Harmonic Regenerative

... connection to adjacent units –– Integrated control bus in each unit for efficient distribution of auxiliary 24V, 240V, and an optional 120V throughout a cabinet line up • Gain energy efficiency with coordinated motors that share energy between regenerating and motoring loads ...
Telegonos_manual
Telegonos_manual

... but with certain power limitations. The optimal efficiency is achieved with about 1.5 Ohm. The battery holder is powered up by consecutive fast pressing of the button for 1 to 5 times, see extended functions menu (Oc “On clicks”). With continued pressing of the button the user steps through the prog ...
ECE 309 - Clemson University
ECE 309 - Clemson University

... such as resistors, inductors, and capacitors also improves the appearance of the notebook. The engineer doing the recording must decide on the trade-off between the time required and the appearance and readability the notebook. Tables should be used to list observed data as well as data calculated d ...
the flea - Acoustica.org.uk
the flea - Acoustica.org.uk

mosfet jfet
mosfet jfet

... • Insulators – Ex: Plastics – Flow of electricity governed by motion of ions that break free – As temperature increases, conductivity increases due to lattice vibrations breaking free ions – Irrelevant because conductive temperature beyond melting point ...
Hola Agustin - Portal UniMAP
Hola Agustin - Portal UniMAP

... One portion of the winding serves for both the primary and the secondary. If the transformer is being used to lower the voltage, the turns between H1 and H2 constitute the primary winding and those between L1 and L2 constitute the secondary winding. The ratio of the voltage, as in a two-winding tran ...
BD6072HFN
BD6072HFN

CURRICULUM VITAE - Northeastern University
CURRICULUM VITAE - Northeastern University

... A. Shrivastava, Y. Ramadass, and S. Bartling “Single inductor energy management and harvesting interface system and method” US Patent Application Number: 20140103728. A. Shrivastava, “Output buffer with improved output signal quality” US Patent Application Number: ...
Negative-Sequence Impedance Directional Element
Negative-Sequence Impedance Directional Element

... Pullman, WA USA ...
DB_MS8886A
DB_MS8886A

MAX1917 Tracking, Sinking and Sourcing, Synchronous Buck General Description
MAX1917 Tracking, Sinking and Sourcing, Synchronous Buck General Description

... The MAX1917 provides a complete power-management solution for DDR memory. It contains a synchronous buck controller and an amplifier to generate 1/2VDDR voltage for VTT and VTTR. The VTT and VTTR voltages are maintained within 1% of 1/2VDDR. The controller operates in synchronous rectification mode ...
HMC416LP4 数据资料DataSheet下载
HMC416LP4 数据资料DataSheet下载

... Covering 2.75 to 3.0 GHz, the VCO’s phase noise performance is excellent over temperature, shock, vibration and process due to the oscillator’s monolithic structure. Power output is 4.5 dBm typical from a single supply of 3V @ 37 mA. The voltage controlled oscillator is packaged in a low cost leadle ...
Short-circuit current ratings 3MB
Short-circuit current ratings 3MB

... • NEC® Article 100 Definition • Highest current an OVERCURRENT DEVICE (fuse or circuit breaker) is rated to safely interrupt. • Self protection rating only ...
12 to 6 Volt Regulator - Studebaker
12 to 6 Volt Regulator - Studebaker

IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)

... burden for Contemporary systems [1]. Dynamic energy is proportional to the square of the supply voltage. Thus, a lower voltage level yields a quadratic reduction in the energy consumption. To further reduce the dynamic power, systems-on-chip (SoCs) are partitioned into voltage islands with separate ...
en 50160 cenelec - Schneider Electric
en 50160 cenelec - Schneider Electric

... For the purpose of this standard a voltage, whose upper limit of nominal rms value is 1 kV. 1.3.8 medium voltage (abbreviation: MV) For the purpose of this standard a voltage, whose nominal rms value lies above 1 kV and below 35 kV. 1.3.9 normal operating condition For a distribution network the con ...
Trane TR200
Trane TR200

unit 3 - WordPress.com
unit 3 - WordPress.com

< 1 ... 410 411 412 413 414 415 416 417 418 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report