Mazda 626 GE 2.0 FS
... connects this terminal to ground. The voltage on this terminal is during this time 0 Volts. During the time the solenoid is switched off, the voltage on this terminal is 12 Volts. Some motormanagement systems control the amount gases delivered to the intake manifold switching the solenoid on and of ...
... connects this terminal to ground. The voltage on this terminal is during this time 0 Volts. During the time the solenoid is switched off, the voltage on this terminal is 12 Volts. Some motormanagement systems control the amount gases delivered to the intake manifold switching the solenoid on and of ...
Dual-mode Multiphase Sinusoidal Oscillator using CDBAs
... By substituting our proposed sub-circuits into the general block diagram of the MSO in fig. 3, the complete circuit of the CDBA-based MSO for N = 3, which has 60° phase difference, can be obtained as shown in fig. 5. Since our proposed structure exploits an advantage of having both voltage and curre ...
... By substituting our proposed sub-circuits into the general block diagram of the MSO in fig. 3, the complete circuit of the CDBA-based MSO for N = 3, which has 60° phase difference, can be obtained as shown in fig. 5. Since our proposed structure exploits an advantage of having both voltage and curre ...
FPF2193 / FPF2194 / FPF2195 — Full Function Load Switch wit
... Current Limit Set Input. A resistor from ISET to ground sets the current limit for the switch. ...
... Current Limit Set Input. A resistor from ISET to ground sets the current limit for the switch. ...
BLM.gov Home Page | BUREAU OF LAND MANAGEMENT
... examine either rock fragments or long cores of rock that are brought up from deep within the well. Water samples are taken from any groundwater encountered during drilling. Also, temperatures are measured at depth. Both well temperatures and the results of rock sample analyses are used to determine ...
... examine either rock fragments or long cores of rock that are brought up from deep within the well. Water samples are taken from any groundwater encountered during drilling. Also, temperatures are measured at depth. Both well temperatures and the results of rock sample analyses are used to determine ...
Constant Current Regulator LED Circuit Enhanced for
... provides a dummy load, then switches in the real LEDs after the dimmer has had time to begin normal operation. First, the circuit temporarily separates the LEDs from the supply voltage with a switching mechanism comprising 4 transistors and two diodes. U3, a high voltage NFET, is controlled by the R ...
... provides a dummy load, then switches in the real LEDs after the dimmer has had time to begin normal operation. First, the circuit temporarily separates the LEDs from the supply voltage with a switching mechanism comprising 4 transistors and two diodes. U3, a high voltage NFET, is controlled by the R ...
MP830
... for 3 phase AC induction motor systems. The unit is a phase angle, current sensing and voltage sensing relay, that can automatically set up trip points within specified limits around the normal operating conditions of a particular motor system. An adjustable restart timer, triggered by an underload ...
... for 3 phase AC induction motor systems. The unit is a phase angle, current sensing and voltage sensing relay, that can automatically set up trip points within specified limits around the normal operating conditions of a particular motor system. An adjustable restart timer, triggered by an underload ...
RV4141A — Low-Power, Ground
... The GFCI detects a ground fault by sensing a difference in current in the line and neutral wires. The difference in current is assumed to be a fault current creating a potentially hazardous path from line to ground. Since the line and neutral wires pass through the center of the sense transformer, o ...
... The GFCI detects a ground fault by sensing a difference in current in the line and neutral wires. The difference in current is assumed to be a fault current creating a potentially hazardous path from line to ground. Since the line and neutral wires pass through the center of the sense transformer, o ...
HMC224MS8 / 224MS8E
... The HMC224MS8 & HMC224MS8E are low-cost SPDT switches in 8-lead MSOP packages for use in transmit-receive applications. The device can control signals from 5.0 to 6.0 GHz and is especially suited for 5.2 GHz UNII and 5.8 GHz ISM applications with only 1.2 dB loss. The design provides exceptional pow ...
... The HMC224MS8 & HMC224MS8E are low-cost SPDT switches in 8-lead MSOP packages for use in transmit-receive applications. The device can control signals from 5.0 to 6.0 GHz and is especially suited for 5.2 GHz UNII and 5.8 GHz ISM applications with only 1.2 dB loss. The design provides exceptional pow ...
PS-5006
... As well as ensuring accurate voltage balancing active circuits typically draw much lower levels of current in steady state and only require larger currents when the capacitor voltage goes out of balance. These characteristics make active voltage balancing circuits ideal for applications that charge ...
... As well as ensuring accurate voltage balancing active circuits typically draw much lower levels of current in steady state and only require larger currents when the capacitor voltage goes out of balance. These characteristics make active voltage balancing circuits ideal for applications that charge ...
all other uses, in any ... © 2012 IEEE
... The European Union has committed itself to source 20% of its energy from renewables by 2020 [1]. As the most promising candidate, the wind energy production integrated into the power grid is booming up all over the world. Meanwhile, the power capacity of a single wind turbine is increasing continuou ...
... The European Union has committed itself to source 20% of its energy from renewables by 2020 [1]. As the most promising candidate, the wind energy production integrated into the power grid is booming up all over the world. Meanwhile, the power capacity of a single wind turbine is increasing continuou ...
SZM-3166Z 3.3GHz to 3.6GHz 2W POWER AMPLIFIER Features Product Description
... This is the collector of the first stage. This is the supply voltage for the active bias circuit of the 1st and 2nd stages. This pin is not connected inside the package, but it is recommended to connect it to GND to achieve the specified performance. This is the RF input pin. It is DC grounded insid ...
... This is the collector of the first stage. This is the supply voltage for the active bias circuit of the 1st and 2nd stages. This pin is not connected inside the package, but it is recommended to connect it to GND to achieve the specified performance. This is the RF input pin. It is DC grounded insid ...
HGTG10N120BN, HGTP10N120BN, HGT1S10N120BNS 35A, 1200V, NPT Series N-Channel IGBT Features
... 1. Prior to assembly into a circuit, all leads should be kept shorted together either by the use of metal shorting springs or by the insertion into conductive material such as “ECCOSORBD™ LD26” or equivalent. 2. When devices are removed by hand from their carriers, the hand being used should be grou ...
... 1. Prior to assembly into a circuit, all leads should be kept shorted together either by the use of metal shorting springs or by the insertion into conductive material such as “ECCOSORBD™ LD26” or equivalent. 2. When devices are removed by hand from their carriers, the hand being used should be grou ...
a CMOS, Low Voltage RF/Video, SPST Switch ADG751
... consideration should be given to the printed circuit board layout and to grounding. Wire wrap boards, prototype boards and sockets are not recommended because of their high parasitic inductance and capacitance. The part should be soldered directly to a printed circuit board. A ground plane should co ...
... consideration should be given to the printed circuit board layout and to grounding. Wire wrap boards, prototype boards and sockets are not recommended because of their high parasitic inductance and capacitance. The part should be soldered directly to a printed circuit board. A ground plane should co ...
MAX8586 Single 1.2A USB Switch in 3mm x 3mm TDFN General Description
... The MAX8586 single current-limited switch controls up to 1.2A to power USB applications and has multiple protection features including thermal shutdown, internal current limiting, and reverse current protection. The thermal shutdown limits junction temperature during a prolonged short or overload co ...
... The MAX8586 single current-limited switch controls up to 1.2A to power USB applications and has multiple protection features including thermal shutdown, internal current limiting, and reverse current protection. The thermal shutdown limits junction temperature during a prolonged short or overload co ...
Vacuum Interrupters and X
... As reported in some excerpts from Appendix A of C37.85-2002, “As a result of evaluating the results of the aforementioned tests, the manufacturers (of vacuum interrupters) concluded that neither the general public or users will be subjected to harmful X-radiation due to normal application and operat ...
... As reported in some excerpts from Appendix A of C37.85-2002, “As a result of evaluating the results of the aforementioned tests, the manufacturers (of vacuum interrupters) concluded that neither the general public or users will be subjected to harmful X-radiation due to normal application and operat ...
Electrical substation
A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.