docx
... pin package modeling without additional keywords. Since the [Merged Pins] keyword (defined below) provides a mechanism to explicitly and unambiguously define the connectivity of merged pins with greater detail and freedom, the use of the [Merged Pins] keyword is strongly recommended for new models i ...
... pin package modeling without additional keywords. Since the [Merged Pins] keyword (defined below) provides a mechanism to explicitly and unambiguously define the connectivity of merged pins with greater detail and freedom, the use of the [Merged Pins] keyword is strongly recommended for new models i ...
MACH Power
... MACH® devices have been designed with the capability to reset during system power-up. Following power-up, all flip-flops will be reset to LOW. The output state will depend on the logic polarity. This feature provides extra flexibility to the designer and is especially valuable in simplifying state m ...
... MACH® devices have been designed with the capability to reset during system power-up. Following power-up, all flip-flops will be reset to LOW. The output state will depend on the logic polarity. This feature provides extra flexibility to the designer and is especially valuable in simplifying state m ...
Cyclone Inline Fans
... The fan must be connected to power mains through an automatic circuit breaker integrated into the fixed wiring system with the gap between the breaker contacts on all poles not less than 3 mm. Check the fan for any visible damages of the impeller and the casing before starting installation. The casi ...
... The fan must be connected to power mains through an automatic circuit breaker integrated into the fixed wiring system with the gap between the breaker contacts on all poles not less than 3 mm. Check the fan for any visible damages of the impeller and the casing before starting installation. The casi ...
MY-64 Digital Multimeter use
... can destroy your meter. In dry conditions, even moving in your chair can create a large charge of static electricity on you. Always ground yourself to something (e.g. touch something metal) before opening the meter case. The ECE department is not responsible for meters damaged by abuse or static dis ...
... can destroy your meter. In dry conditions, even moving in your chair can create a large charge of static electricity on you. Always ground yourself to something (e.g. touch something metal) before opening the meter case. The ECE department is not responsible for meters damaged by abuse or static dis ...
Device circuit breakers - the basics
... breakers are used in the field of power distribution. They mainly protect power cables in buildings or systems that supply terminal devices, building floors or building complexes with current. However, it is not the task of the circuit breaker to protect loads and terminal devices. It is only in the ...
... breakers are used in the field of power distribution. They mainly protect power cables in buildings or systems that supply terminal devices, building floors or building complexes with current. However, it is not the task of the circuit breaker to protect loads and terminal devices. It is only in the ...
BC847BLP4 Features Mechanical Data
... Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use o ...
... Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use o ...
10V Precision Voltage Reference (Rev. B)
... BASIC CIRCUIT CONNECTION Figure 2 shows the proper connection of the REF102. To achieve the specified performance, pay careful attention to layout. A low resistance star configuration will reduce voltage errors, noise pickup, and noise coupled from the power supply. Commons should be connected as in ...
... BASIC CIRCUIT CONNECTION Figure 2 shows the proper connection of the REF102. To achieve the specified performance, pay careful attention to layout. A low resistance star configuration will reduce voltage errors, noise pickup, and noise coupled from the power supply. Commons should be connected as in ...
LM358 LOW POWER DUAL OPERATIONAL AMPLIFIERS Description
... 6. VO ≅ 1.4V, RS = 0Ω with V+ from 5V to 30V; and over the full input common-mode range (0V to V+ -1.5V) at 25°C. 7. The direction of the input current is out of the IC due to the PNP input stage. This current is essentially constant, independent of the state of the output so no loading change exist ...
... 6. VO ≅ 1.4V, RS = 0Ω with V+ from 5V to 30V; and over the full input common-mode range (0V to V+ -1.5V) at 25°C. 7. The direction of the input current is out of the IC due to the PNP input stage. This current is essentially constant, independent of the state of the output so no loading change exist ...
6-Bit Voltage Output Multiplying DAC Datasheet MDAC6 V 2.2
... Alternatively, input codes may be represented in offset-binary form, as a number ranging from 0 to 62. This means that a one-step change in the output voltage represents one sixty-third of the full-scale output range, rather than the more typical one sixty-fourth. In sign and magnitude form, the inp ...
... Alternatively, input codes may be represented in offset-binary form, as a number ranging from 0 to 62. This means that a one-step change in the output voltage represents one sixty-third of the full-scale output range, rather than the more typical one sixty-fourth. In sign and magnitude form, the inp ...
Installation shipped after Serial #14125
... Through the use of Pulse Width Modulation (PWM) and the latest MOSFET technology, PWSeries can produce a pure sine wave output which is compatible with all types of lighting loads. A high crest factor of 2.5 is extremely beneficial for high inrush loads and also ideal for bringing normally off light ...
... Through the use of Pulse Width Modulation (PWM) and the latest MOSFET technology, PWSeries can produce a pure sine wave output which is compatible with all types of lighting loads. A high crest factor of 2.5 is extremely beneficial for high inrush loads and also ideal for bringing normally off light ...
UCC28730 Constant-Voltage, Constant-Current
... threshold across the AC-input range. For the AC-input Run/Stop function, the Run threshold on VS is 225 µA and the Stop threshold is 80 µA. At the end of off-time demagnetization, the reflected output voltage is sampled at this pin to provide regulation and overvoltage protection. The values for the ...
... threshold across the AC-input range. For the AC-input Run/Stop function, the Run threshold on VS is 225 µA and the Stop threshold is 80 µA. At the end of off-time demagnetization, the reflected output voltage is sampled at this pin to provide regulation and overvoltage protection. The values for the ...
Axials Series C4C, C4G, C4H, C4M, C4T
... breakdown. The dielectric in the capacitor is subjected to the full potential to which the device is charged and, high electrical stresses are common. Dielectric breakdowns may develop after many hours of satisfactory operation. There are several causes which could be associated with operational fai ...
... breakdown. The dielectric in the capacitor is subjected to the full potential to which the device is charged and, high electrical stresses are common. Dielectric breakdowns may develop after many hours of satisfactory operation. There are several causes which could be associated with operational fai ...
Voltage Support Provided by STATCOM in Unbalanced Power
... Nowadays, there are grid operators that allow providing unbalanced currents so that the power at the PCC remains constant. This is very useful in weak grids because it allows connecting all loads to a balanced PCC voltage, which is especially important for sensitive loads that could disconnect if th ...
... Nowadays, there are grid operators that allow providing unbalanced currents so that the power at the PCC remains constant. This is very useful in weak grids because it allows connecting all loads to a balanced PCC voltage, which is especially important for sensitive loads that could disconnect if th ...
Local Distribution Company (LDC) Form B
... If any part of the LDC’s distribution system that is downstream from the above TS, includes existing or proposed queue generators, the LDC must provide details of that generation in the attached Appendix B. Please attach one copy of your company’s completed Form B as submitted by your generation pro ...
... If any part of the LDC’s distribution system that is downstream from the above TS, includes existing or proposed queue generators, the LDC must provide details of that generation in the attached Appendix B. Please attach one copy of your company’s completed Form B as submitted by your generation pro ...
Chapter 8
... – some devices allow voltages up to 30 V or more – others, designed for low voltages, may use 1.5 V – many op-amps permit single voltage supply operation, typically in the range 4 to 30 V Storey: Electrical & Electronic Systems © Pearson Education Limited 2004 ...
... – some devices allow voltages up to 30 V or more – others, designed for low voltages, may use 1.5 V – many op-amps permit single voltage supply operation, typically in the range 4 to 30 V Storey: Electrical & Electronic Systems © Pearson Education Limited 2004 ...
POWER PAC 300 POWER PAC 200
... This instrument is intended for laboratory use only. This product conforms to the “Class A” standards for Electromagnetic Emissions, intended for laboratory equipment applications. It is possible that emissions from this product may interfere with some sensitive appliances when placed nearby or on t ...
... This instrument is intended for laboratory use only. This product conforms to the “Class A” standards for Electromagnetic Emissions, intended for laboratory equipment applications. It is possible that emissions from this product may interfere with some sensitive appliances when placed nearby or on t ...
AN1048/D RC Snubber Networks For Thyristor Power Control and
... normal current amplitude at start-up. This increases both junction temperature and the rate of current crossing, leading to turn-off problems. The line frequency causes high rates of current crossing in 400 Hz applications. Resonant transformer circuits are doubly periodic and have current harmonics ...
... normal current amplitude at start-up. This increases both junction temperature and the rate of current crossing, leading to turn-off problems. The line frequency causes high rates of current crossing in 400 Hz applications. Resonant transformer circuits are doubly periodic and have current harmonics ...
Evaluates: MAX8568A/MAX8568B MAX8568A Evaluation Kit General Description Features
... The MAX8568A evaluation kit (EV kit) is a fully assembled and tested circuit board that evaluates the MAX8568A and MAX8568B complete backup-management ICs for lithium and NiMH batteries. The MAX8568A EV kit can charge both NiMH and rechargeable lithium battery types; the EV kit default setting is fo ...
... The MAX8568A evaluation kit (EV kit) is a fully assembled and tested circuit board that evaluates the MAX8568A and MAX8568B complete backup-management ICs for lithium and NiMH batteries. The MAX8568A EV kit can charge both NiMH and rechargeable lithium battery types; the EV kit default setting is fo ...
Electrical substation
A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.