• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Team D - Electrical Engineering @ NMT
Team D - Electrical Engineering @ NMT

... on alternating-current supplies. A robust alternative-energy power supply should therefore include a high-efficiency DC to AC power inverter capable of providing an output analogous to home wall power (60 hertz, 120 volts RMS in the United States). Furthermore, since devices such as solar panels pro ...
Paralleling Dissimilar Generators
Paralleling Dissimilar Generators

... two machines, or drops 750 kW in one step from the two machines, they will not share loads equally during the transient period. It is possible to have the system exposed to potential overcurrent conditions on the faster machine or nuisance reverse power faults on load rejection. At lower load levels ...
Western Offshore Transmission Grid
Western Offshore Transmission Grid

... in £/MW.km) of overhead lines is significantly less than submarine or underground cable alternatives and hence overhead lines would be expected to be used when practical and acceptable. However, where this is not the case, offshore submarine cable based schemes will provide a lower cost reinforcemen ...
INA19xA-Q1: Current Shunt Monitors With -16-V to 80
INA19xA-Q1: Current Shunt Monitors With -16-V to 80

... The value chosen for the shunt resistor, RS, depends on the application and is a compromise between smallsignal accuracy and maximum permissible voltage loss in the measurement line. High values of RS provide better accuracy at lower currents by minimizing the effects of offset, while low values of ...
ST6 - CONTROLLING A BRUSH DC MOTOR WITH AN ST6265
ST6 - CONTROLLING A BRUSH DC MOTOR WITH AN ST6265

... buttons, potentiometers, LED displays, even LCD displays. If the analog approach is used, more circuitry will be needed to interface them with the motor drive. With the ST6265 MCU approach, the MCU itself can sense the buttons, potentiometers, drive LEDS... In some existing appliances, the analog ap ...
Aalborg Universitet Reduced junction temperature control during low-voltage ride-through for single-
Aalborg Universitet Reduced junction temperature control during low-voltage ride-through for single-

... hardware schematic of an LCL-filter based single-phase singlestage full-bridge PV system with the proposed control structure. Standard functionalities for a PV inverter are a) optimization/maximization of the input power, b) manipulation of the inverter output voltage (i.e. voltage control), and c) ...
Diapositiva 1 - WikiService.at
Diapositiva 1 - WikiService.at

... to interconnect large portions of national power grids. All operate with the same basic principles and with many similarities in their parts. ...
ifac 2011 297 final
ifac 2011 297 final

... adjust electrical impedance on electrical terminals. Both requirements need to be realized by controlling power converter which is attached between electrical machine and the electrical power source. In some cases, due to topological properties of the converters, concurrent realization of both requi ...
TPS65137 数据资料 dataSheet 下载
TPS65137 数据资料 dataSheet 下载

... Conduction Mode) the converter operates in peak current control using fixed off time control. ...
MP3450/MP3500/MP3600 User Guide (V1.0)
MP3450/MP3500/MP3600 User Guide (V1.0)

... A battery has a finite life. It is slowly degrading all the time, even if it is not used. It is due to a chemical reaction that gradually causes the internal impedance of the cells increase and reduces the ability of the battery to deliver its charge. All chemical reactions are affected by extreme h ...
bosch and nosso voltage regulators
bosch and nosso voltage regulators

... The Bosch and Nosso regulators that are used in the Isetta and BMW 600 seem to be mysterious devices to many Isetta owners. This document is an attempt to revel some of its mysteries. The two regulators are the same device with the exception of the terminals nomenclature on the outside of the cases. ...
SIRCO MC PV
SIRCO MC PV

... sirco-MC 056 a gb ...
Full-Text PDF
Full-Text PDF

... made by modern distance relays in less than one cycle. However, the operating time of the relay and its give the distance of fault location are not the only factor to be considered while selecting a distance protection for a transmission line that requires dynamic loading but also the loading of tra ...
Optimal output filter design for microprocessor
Optimal output filter design for microprocessor

... an ideal controller, output inductor (LO), and output bulk capacitor (CO) with equivalent series resistance (ESR) and equivalent series inductance (ESL). The equivalent resistor (RB) represents the added resistance of traces and connectors and characterizes a resistive voltage drop through the suppl ...
Technical Note 6297: Neutral Conductor Size for Sunny Boy
Technical Note 6297: Neutral Conductor Size for Sunny Boy

Old Company Name in Catalogs and Other Documents
Old Company Name in Catalogs and Other Documents

... You should use the Renesas Electronics products described in this document within the range specified by Renesas Electronics, especially with respect to the maximum rating, operating supply voltage range, movement power voltage range, heat radiation characteristics, installation and other product ch ...
MAX1730 50mA Regulated Step-Down Charge Pump for 1.8V or 1.9V Logic General Description
MAX1730 50mA Regulated Step-Down Charge Pump for 1.8V or 1.9V Logic General Description

... Charge pumps work by passing energy through capacitors. They generally work in two phases. In the first phase, the input source charges the flying capacitors. The input capacitor helps reduce the source’s input impedance. In the second phase, the switching capacitors transfer their charge to the out ...
Engineering Analysis -Conservation Voltage Reduction in WindMil
Engineering Analysis -Conservation Voltage Reduction in WindMil

... CVR is the concept of lowering the utilization voltage to end-use consumers such that their demands, and energy consumption, decreases, with the most noteworthy benefit being the demand reduction during peak periods in which the cost of power is at its maximum due to the high cost to run peaking gen ...
Test Report
Test Report

Power Switching Devices and their Static Electrical Characteristics
Power Switching Devices and their Static Electrical Characteristics

... taken to avoid premature breakdown across the edge of the die or where the junction surfaces. Premature edge breakdown is reduced by bevelling the edge as shown in figure 3.la, or by diffusing a guard ring as shown in figure 3.lb, which isolates the junction from the edge of the wafer. The scl elect ...
LCD display
LCD display

... Measuring resistance ...
CHAPTER 2: Diode Applications (Aplikasi Diod)
CHAPTER 2: Diode Applications (Aplikasi Diod)

variable frequency 101
variable frequency 101

... case, we will limit our discussion to three phase motors used on three phase drives. The DC Bus The second component, known as the DC Bus (shown in the center of the illustration) is not seen and in all VFD’s because it does not contribute directly to variable frequency operation. But, it will alway ...
Installation Guidelines for Prime Power Application
Installation Guidelines for Prime Power Application

... a circuit breaker, care must be taken with the protection settings. Circuit breakers are designed for operation with the utility supply, which can provide much higher and longer fault levels than a generator. The circuit breaker overcurrent and short circuit settings should therefore be set accordin ...
Chapter 11 Constant Voltage Transformer (CVT)
Chapter 11 Constant Voltage Transformer (CVT)

< 1 ... 338 339 340 341 342 343 344 345 346 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.