FJP5555 NPN Silicon Transistor FJP5555 — NPN Silicon T
... Distributors who are listed by country on our web page cited above. Products customers buy either from Fairchild directly or from Authorized Fairchild Distributors are genuine parts, have full traceability, meet Fairchild's quality standards for handling and storage and provide access to Fairchild's ...
... Distributors who are listed by country on our web page cited above. Products customers buy either from Fairchild directly or from Authorized Fairchild Distributors are genuine parts, have full traceability, meet Fairchild's quality standards for handling and storage and provide access to Fairchild's ...
Systems-Level Trade Studies of a Dual
... stationkeeping. The GEO mass benefits could be increased even further with a dual-mode SPT-140 subsystem, i.e. one that is designed for optimal performance in two different modes. This paper will present the results of systems-level trade studies of a dual-mode subsystem, based on the SPT-140 subsys ...
... stationkeeping. The GEO mass benefits could be increased even further with a dual-mode SPT-140 subsystem, i.e. one that is designed for optimal performance in two different modes. This paper will present the results of systems-level trade studies of a dual-mode subsystem, based on the SPT-140 subsys ...
FXMA2104 Dual-Supply, 4-Bit Voltage Translator / Buffer /
... specification voltage levels. External pull-up resistors are required. The device is designed so that the A port tracks the VCCA level and the B port tracks the VCCB level. This allows for bi-directional A/B port voltage translation between any two levels from 1.65V to 5.5V. VCCA can equal VCCB from ...
... specification voltage levels. External pull-up resistors are required. The device is designed so that the A port tracks the VCCA level and the B port tracks the VCCB level. This allows for bi-directional A/B port voltage translation between any two levels from 1.65V to 5.5V. VCCA can equal VCCB from ...
HPI- Inverter operating Instructions
... wiring socket outlet), components inside the INVERTER system are still connected to the battery and are still electrically live and dangerous. Before carrying out any kind of servicing and/or maintenance, disconnect the batteries and verify that no current is present. 2. Batteries may cause electric ...
... wiring socket outlet), components inside the INVERTER system are still connected to the battery and are still electrically live and dangerous. Before carrying out any kind of servicing and/or maintenance, disconnect the batteries and verify that no current is present. 2. Batteries may cause electric ...
AP7331 300mA, LOW QUIESCENT CURRENT, FAST TRANSIENT LOW DROPOUT LINEAR REGULATOR
... glitch and noise. The amount of the capacitance may be increased without limit. This input capacitor must be located as close as possible to the device to assure input stability and less noise. For PCB layout, a wide copper trace is required for both VIN and GND. A lower ESR capacitor allows the use ...
... glitch and noise. The amount of the capacitance may be increased without limit. This input capacitor must be located as close as possible to the device to assure input stability and less noise. For PCB layout, a wide copper trace is required for both VIN and GND. A lower ESR capacitor allows the use ...
Transient Recovery Voltages During the Switching Under Out
... switching follow necessarily from that data. § For the three examples appropriate models have been chosen to represent the TRV behaviour of the system source faults and the generator-source faults. TRV calculations for these models at 90°el. out-ofphase conditions show a good fit with [4] regarding ...
... switching follow necessarily from that data. § For the three examples appropriate models have been chosen to represent the TRV behaviour of the system source faults and the generator-source faults. TRV calculations for these models at 90°el. out-ofphase conditions show a good fit with [4] regarding ...
Evaluates: MAX8543/MAX8544 MAX8544 Evaluation Kit General Description Features
... 1-888-629-4642, or visit Maxim’s website at www.maxim-ic.com. ...
... 1-888-629-4642, or visit Maxim’s website at www.maxim-ic.com. ...
... other equipment, ground faults, undersized power systems, and lightning all produce voltage sags. Surges may be generated when large electrical loads are shut off. Pages 7 & 8 illustrate the problems caused by low or high voltages. Impulses, Spikes & Transients are all names used to describe very sh ...
... Operator (ISO) must receive from owners of transmission system equipment and facilities, in order to maintain an accurate comprehensive data model of the Alberta Interconnected Electric System adequate for regulatory analysis, power system studies, asset type and location impact assessment, and real ...
MAX1488E ±15kV ESD-Protected, Quad, Low-Power RS-232 Line Driver _______________General Description
... The IEC1000-4-2 standard covers ESD testing and performance of finished equipment; it does not specifically refer to integrated circuits. The MAX1488E helps you design equipment that meets Level 4 (the highest level) of IEC1000-4-2, without additional ESD-protection components. The major difference ...
... The IEC1000-4-2 standard covers ESD testing and performance of finished equipment; it does not specifically refer to integrated circuits. The MAX1488E helps you design equipment that meets Level 4 (the highest level) of IEC1000-4-2, without additional ESD-protection components. The major difference ...
Section 26 23 00, Low-Voltage Switchgear
... drawings, shall interconnect the neutral and ground buses, when the switchgear is used to establish the system common ground point. 6. All bolts, nuts, and washers shall be //zinc-plated//cadmiumplated// steel. Bolts shall be torqued to the values recommended by the manufacturer. 7. Make provisions ...
... drawings, shall interconnect the neutral and ground buses, when the switchgear is used to establish the system common ground point. 6. All bolts, nuts, and washers shall be //zinc-plated//cadmiumplated// steel. Bolts shall be torqued to the values recommended by the manufacturer. 7. Make provisions ...
PowerPoint - UCF Physics
... Consider a solenoid with N turns that is very long. We assume that the field is uniform throughout its length, ignoring any “end effects”. For a long enough solenoid, we can get away with it for the following argument. Maybe. ...
... Consider a solenoid with N turns that is very long. We assume that the field is uniform throughout its length, ignoring any “end effects”. For a long enough solenoid, we can get away with it for the following argument. Maybe. ...
MAX1958/MAX1959 W-CDMA/N-CDMA Cellular Phone HBT PA Management ICs General Description
... The high-efficiency, pulse-width modulated (PWM), DCto-DC buck converter is optimized to provide a guaranteed output current of 800mA. The output voltage is dynamically controlled to produce any fixed-output voltage in the range of 0.75V to 3.4V (MAX1958) or 1V to 3.6V (MAX1959), with settling time ...
... The high-efficiency, pulse-width modulated (PWM), DCto-DC buck converter is optimized to provide a guaranteed output current of 800mA. The output voltage is dynamically controlled to produce any fixed-output voltage in the range of 0.75V to 3.4V (MAX1958) or 1V to 3.6V (MAX1959), with settling time ...
Electric Generator - KFUPM Faculty List
... installed before 1977 were not required to have scrubbers on them. This means that these generators are pouring out pure unfiltered pollution into the air. This is blowing over shopping centers, residential areas, schools, and the hospital, and can cause many health problems .another limitation is I ...
... installed before 1977 were not required to have scrubbers on them. This means that these generators are pouring out pure unfiltered pollution into the air. This is blowing over shopping centers, residential areas, schools, and the hospital, and can cause many health problems .another limitation is I ...
TPS75601 数据资料 dataSheet 下载
... device will be in shutdown or sleep mode. When EN goes to a high voltage level (> 2 V), the device will be enabled. Feedback (FB) FB is an input terminal used for the adjustable-output option and must be connected to the output terminal either directly, in order to generate the minimum output voltag ...
... device will be in shutdown or sleep mode. When EN goes to a high voltage level (> 2 V), the device will be enabled. Feedback (FB) FB is an input terminal used for the adjustable-output option and must be connected to the output terminal either directly, in order to generate the minimum output voltag ...
AP4340S Datasheet - Diodes Incorporated
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
Installing Grounding Lug Kits on Cisco 4000 Series Routers
... Electrostatic discharge (ESD) can damage equipment and impair electrical circuitry. ESD can occur when printed circuit cards are improperly handled and can result in complete or intermittent failures. Always follow ESD prevention procedures when removing and replacing cards. Ensure that the router c ...
... Electrostatic discharge (ESD) can damage equipment and impair electrical circuitry. ESD can occur when printed circuit cards are improperly handled and can result in complete or intermittent failures. Always follow ESD prevention procedures when removing and replacing cards. Ensure that the router c ...
Electrical substation
A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.