TPS4021x 4.5-V to 52-V Input Current Mode Boost Controller (Rev. F)
... System input voltage. Connect a local bypass capacitor from this pin to GND. Depending on the amount of required slope compensation, this pin can be connected to the converter output. See Application Information section for additional details. ...
... System input voltage. Connect a local bypass capacitor from this pin to GND. Depending on the amount of required slope compensation, this pin can be connected to the converter output. See Application Information section for additional details. ...
New Open LED Shunt Protection (LSP) Devices
... Help Prevent High Reliability LED Lighting Application Failures COMMON THREATS IN LED LIGHTING SYSTEMS In order to understand the advantages Bourns® LSP devices give to LED lighting circuit protection, it is worthwhile to explore the basic threats to LEDs and the associated failure modes. First, the ...
... Help Prevent High Reliability LED Lighting Application Failures COMMON THREATS IN LED LIGHTING SYSTEMS In order to understand the advantages Bourns® LSP devices give to LED lighting circuit protection, it is worthwhile to explore the basic threats to LEDs and the associated failure modes. First, the ...
4.5V to 40V Input Automotive Flyback/Boost/SEPIC Power-Supply Controllers General Description Features
... 4.5V to 40V Input Automotive Flyback/Boost/SEPIC Power-Supply Controllers General Description The MAX15004A/B/MAX15005A/B high-performance, current-mode PWM controllers operate at an automotive input voltage range from 4.5V to 40V (load dump). The input voltage can go down as low as 2.5V after start ...
... 4.5V to 40V Input Automotive Flyback/Boost/SEPIC Power-Supply Controllers General Description The MAX15004A/B/MAX15005A/B high-performance, current-mode PWM controllers operate at an automotive input voltage range from 4.5V to 40V (load dump). The input voltage can go down as low as 2.5V after start ...
Insulated Gate Bipolar Transistor (Ultrafast Speed IGBT), 100 A
... about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specification ...
... about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specification ...
AAT4611 数据资料DataSheet下载
... MOSFET power switch designed for high-side load switching applications. This switch operates with inputs ranging from 2.7V to 5.5V, making it ideal for both 3V and 5V systems. An integrated current-limiting circuit protects the input supply against large currents which may cause the supply to fall o ...
... MOSFET power switch designed for high-side load switching applications. This switch operates with inputs ranging from 2.7V to 5.5V, making it ideal for both 3V and 5V systems. An integrated current-limiting circuit protects the input supply against large currents which may cause the supply to fall o ...
TPS2379 - Texas Instruments
... The CDB pin can inhibit downstream converter start up by keeping the soft start pin low. Figure 16 shows where the CDB connects to the SS pin of a UCC2897A DC-DC controller. Because CDB is an open drain output, it will not affect the soft start capacitor charge time when it deasserts. The CDB pin ca ...
... The CDB pin can inhibit downstream converter start up by keeping the soft start pin low. Figure 16 shows where the CDB connects to the SS pin of a UCC2897A DC-DC controller. Because CDB is an open drain output, it will not affect the soft start capacitor charge time when it deasserts. The CDB pin ca ...
High-Precision, Low-Noise, Rail-to-Rail Output, 11MHz JFET Op Amp OPA140 OPA2140,
... Junction-to-board characterization parameter ...
... Junction-to-board characterization parameter ...
Design Methodology for Transformers Including Integrated
... simulation model. The gain peaks have an especially big difference between the two models. 2.2 Soft Switching Conditions The LLC resonant converter can be designed to operate under ZVS and ZCS conditions over the entire load range. In general, the operating frequency is set lower than the first reso ...
... simulation model. The gain peaks have an especially big difference between the two models. 2.2 Soft Switching Conditions The LLC resonant converter can be designed to operate under ZVS and ZCS conditions over the entire load range. In general, the operating frequency is set lower than the first reso ...
Infineon Power LED Driver
... A DC/DC converter is also called a switched mode power supply (SMPS). Thus, switching is its main job. The selection of the system switching frequency is important for the selection of the external components (inductor and capacitor size). The system efficiency and the EMC performance are directly r ...
... A DC/DC converter is also called a switched mode power supply (SMPS). Thus, switching is its main job. The selection of the system switching frequency is important for the selection of the external components (inductor and capacitor size). The system efficiency and the EMC performance are directly r ...
MV POWER CAPACITORS AND BANKS
... current fuses. Capacitors banks of higher power (from 600kvar to 1500kvar) are made up of at least six single phase capacitors or three split-phase, without internal fuses, with capacitor bank connected in insulated double star and unbalance protection. In case of capacitors without internal fuses, ...
... current fuses. Capacitors banks of higher power (from 600kvar to 1500kvar) are made up of at least six single phase capacitors or three split-phase, without internal fuses, with capacitor bank connected in insulated double star and unbalance protection. In case of capacitors without internal fuses, ...
Vecto II - CT LAB Power Quality
... qualified and certified electrician/technician with appropriate training and experience with high voltage and current devices. The instrument must be installed in accordance with the approved national electrical codes. If the instrument is used in a manner not specified by the manufacturer, protecti ...
... qualified and certified electrician/technician with appropriate training and experience with high voltage and current devices. The instrument must be installed in accordance with the approved national electrical codes. If the instrument is used in a manner not specified by the manufacturer, protecti ...
Partial Discharge Testing for Switchgear
... Emerson’s Partial Discharge Testing Services Partial discharges are small electrical sparks that occur within the insulation or on the surface of the insulation of medium and high voltage electrical assets. Each discrete partial discharge is the result of an electrical breakdown of a small portion o ...
... Emerson’s Partial Discharge Testing Services Partial discharges are small electrical sparks that occur within the insulation or on the surface of the insulation of medium and high voltage electrical assets. Each discrete partial discharge is the result of an electrical breakdown of a small portion o ...
DRV8313 2.5-A Triple 1/2-H Bridge Driver (Rev
... section, Power Supply Recommendations section, Layout section, Device and Documentation Support section, and Mechanical, Packaging, and Orderable Information section ................................................................................................. 4 ...
... section, Power Supply Recommendations section, Layout section, Device and Documentation Support section, and Mechanical, Packaging, and Orderable Information section ................................................................................................. 4 ...
1ch Small Package High Side Switch ICs Datasheet
... (8) Testing on application boards When testing the IC on an application board, connecting a capacitor directly to a low-impedance output pin may subject the IC to stress. Always discharge capacitors completely after each process or step. The IC’s power supply should always be turned off completely b ...
... (8) Testing on application boards When testing the IC on an application board, connecting a capacitor directly to a low-impedance output pin may subject the IC to stress. Always discharge capacitors completely after each process or step. The IC’s power supply should always be turned off completely b ...
BoxLED XS Plus G15
... electronic feeding is necessary. One common feeding is possible. Cutting within the chain is only allowed between the wiring of the modules. Pay attention to ESD steps when mounting the module. When using power supplies other than OSRAM OPTOTRONIC®, in order to ensure continuous save operation ...
... electronic feeding is necessary. One common feeding is possible. Cutting within the chain is only allowed between the wiring of the modules. Pay attention to ESD steps when mounting the module. When using power supplies other than OSRAM OPTOTRONIC®, in order to ensure continuous save operation ...
Lightning and surge protection for free field PV power plants
... ties involved and offers the necessary protection at reasonable and frequency of lightning discharges. Regions with a high socosts. lar radiation and air humidity are more susceptible to lightning strikes. The regional lightning frequency (lightning strikes per Measures for protecting PV power plant ...
... ties involved and offers the necessary protection at reasonable and frequency of lightning discharges. Regions with a high socosts. lar radiation and air humidity are more susceptible to lightning strikes. The regional lightning frequency (lightning strikes per Measures for protecting PV power plant ...
Analysis of Total Harmonic Distortion in an APD Receiver
... load resistance changes corresponding to a change in the received optical power, the bias voltage of the APD gets modulated leading to a non-linear response of the overall APD receiver. However, when receiving weak optical signals, this non-linearity will be acceptably small [23]. In this paper, a s ...
... load resistance changes corresponding to a change in the received optical power, the bias voltage of the APD gets modulated leading to a non-linear response of the overall APD receiver. However, when receiving weak optical signals, this non-linearity will be acceptably small [23]. In this paper, a s ...
Electrical substation
A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.