• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
TXS02324 数据资料 dataSheet 下载
TXS02324 数据资料 dataSheet 下载

... The TXS02324 supports both Class C (1.8V) or Class B (2.95V) SIM cards. In order to support these cards types, the interface on the SIM side needs to be properly setup. After power up, the system should default to SIM1 card. The following sequence outlines a rudimentary sequence of preparing the SIM ...
AP7335A  300mA, LOW QUIESCENT CURRENT, FAST TRANSIENT LOW DROPOUT LINEAR REGULATOR
AP7335A 300mA, LOW QUIESCENT CURRENT, FAST TRANSIENT LOW DROPOUT LINEAR REGULATOR

... power savings by putting much of the baseband circuitry into standby mode in between transmit cycles. In baseband circuits, the load often transitions virtually instantaneously from 100µA to 100mA. To meet this load requirement, the LDO must react very quickly without a large voltage drop or oversho ...
BU97950FUV
BU97950FUV



... “PhD” — 2012/2/15 — 13:56 — page xiii — #9 ...
Complex Piping Design Guide
Complex Piping Design Guide

... be the outside air temperature. Examples include pipes and equipment located underground or inside buildings. Minimum Start-Up Temperature This temperature differs from the minimum expected ambient in that the heating cable will typically be energized at a higher ambient temperature. This temperatur ...
Transient simulation and analysis of a three-phase five-limb step
Transient simulation and analysis of a three-phase five-limb step

... fore, if the model must also be accurate for these last conditions, a linear inductance in parallel to each iron inductance is needed in the equivalent network. Such inductances are not visualized in the Fig.2~. The linear inductances of the transformer model include three leakage inductances, which ...
Elec Machinery\US\84\8405
Elec Machinery\US\84\8405

... standard does not apply to the design of factory-built, type-tested switchgear for which separate IEC standards exist. This standard does not apply to the requirements for carrying out live working on electrical installations. For the purpose of interpreting this standard, an electrical power instal ...
26. Metering Code Committee - Assam Electricity Regulatory
26. Metering Code Committee - Assam Electricity Regulatory

... purpose under ABT, each Demand Integration Period shall be of 15 minutes duration, which shall commence from 00.00 hours. Any two successive Demand Integration Periods can contain time intervals, which may be non-overlapping (in case of “fixed time window” principle of measurement) or overlapping (i ...
DRM039, Single Phase AC Induction Motor Control Reference Design
DRM039, Single Phase AC Induction Motor Control Reference Design

... load. The switching frequency is fixed at 16 kHz. The r.m.s value of output voltage is proportional to the duty-cycle of the modulation signal (PWM modulation). The first harmonic of the output waveform remains unchanged and is the same as the line voltage. Therefore the circuits are suitable for ap ...
KBJ6005G - KBJ610G Features Mechanical Data
KBJ6005G - KBJ610G Features Mechanical Data

... Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use o ...
Diode Circuits
Diode Circuits

worldwide capacitors
worldwide capacitors

P83599
P83599

... NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installation. This equipment generates, uses and can rad ...
13.Special Diodes Lecture
13.Special Diodes Lecture

HMC322LP4 数据资料DataSheet下载
HMC322LP4 数据资料DataSheet下载

ILUMEN PID SOLUTION
ILUMEN PID SOLUTION

... What is PID? PID or Potential Induced Degradation is a problem that occurs on many photovoltaic panels when they are exposed to a negative voltage to ground. The Ilumen PID solution can regenerate panels affected with PID and prevent PID from happening. This without affecting the inverter and any lo ...
64-0012 Rev B - Magnum Dimensions
64-0012 Rev B - Magnum Dimensions

... the ON/OFF switch on an inverter. This switch also allows additional changes to be made while in Invert mode or while charging. When the inverter is first connected to the batteries, the inverter and remote go through an internal 10-second start-up test. After this test is completed, the remote’s ON ...
Design and Implementation of a Hybrid Electric Bike
Design and Implementation of a Hybrid Electric Bike

... torque requirements, we were limited by space. To reach the appropriate gear reduction given our speed requirement, we were limited by the space between the rear wheel and the chain stay which does not allow for a gear reduction greater than 3 (driven) or 4 (driven) to 1 (drive) using standard chain ...
Acom 1000 Operation Manual
Acom 1000 Operation Manual

... The ACOM1000 HF+6 meters Linear Amplifier is a Safety Class I unit. The third grounding lead of its mains cord (which is colored yellow with two green stripes) and the ground stud on the rear panel of the amplifier, (marked GND) must be connected to the station’s grounding system for safe operation. ...
145 FERC ¶ 61,123 UNITED STATES OF AMERICA FEDERAL
145 FERC ¶ 61,123 UNITED STATES OF AMERICA FEDERAL

... criteria ensures that the identification of circuits is not dependent on only one criterion. In addition, we recognize that the use of existing analyses performed by planning coordinators and information from other entities, including facility owners, assures that existing knowledge of the system is ...
AAT3192 数据资料DataSheet下载
AAT3192 数据资料DataSheet下载

... The AAT3192 is a low-cost charge-pump solution designed to drive up to two white LEDs. The charge pump operates from a 2.7V to 5.5V power source and converts it to voltage levels necessary to drive the LEDs. LED current is individually controlled through integrated current sinks powered from the out ...
4316C-part2
4316C-part2

... 5.1.14 creepage distance — the shortest path between two conductive parts normally carrying current or between a conductive part normally carrying current and a conductive part that is bonded to the protective earthing system, measured along the surface of the insulation. 5.1.15 disconnecting means ...
DATA  SHEET BUJ403A Silicon Diffused Power Transistor
DATA SHEET BUJ403A Silicon Diffused Power Transistor

... party customer(s). Customer is responsible for doing all necessary testing for the customer’s applications and products using NXP Semiconductors products in order to avoid a default of the applications and the products or of the application or use by customer’s third party customer(s). NXP does not ...
Coils and Electronic Controls
Coils and Electronic Controls

... immediately immersed in a solution at 0°C. The thermal shock is repeated five times with the coil monitored for dielectric strength in the solution and functional performance is verified. ...
TLC2654, TLC2654A  Advanced LinCMOS LOW-NOISE CHOPPER-STABILIZED
TLC2654, TLC2654A Advanced LinCMOS LOW-NOISE CHOPPER-STABILIZED

... high chopping frequency of the TLC2654 and TLC2654A (see Figure 1) provides excellent noise performance in a frequency spectrum from near dc to 10 kHz. In addition, intermodulation or aliasing error is eliminated from frequencies up to 5 kHz. This high dc precision and low noise, coupled with the ex ...
< 1 ... 137 138 139 140 141 142 143 144 145 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report