• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
LT8631 - 100V, 1A Synchronous Micropower
LT8631 - 100V, 1A Synchronous Micropower

XP125 INSTALLATION AND OPERATION MANUAL
XP125 INSTALLATION AND OPERATION MANUAL

... 1100 Watt inverter could be rated at 1375 VA at .8 power factor, 1570 VA @ .7 pf, or an incredible 2200 VA @ .5 pf. It is confusing to specify a product in VA, because the power factor must also be specified. Exeltech's XP-Series inverters can output their full rated ...
MGE Catalog 2003 r7
MGE Catalog 2003 r7

safepower-evo-hf
safepower-evo-hf

... LAN, Server and Datacenters: the 0.9 output power factor ensures greater active power availability for efficient UPS loading. e-business and Telecommunications: parallel operation means that the installed UPS size can be increased (up to 6 units) to keep pace with the growth of the organisation. Ind ...
NCL30086 Analog/Digital Dimmable Power Factor Corrected Quasi-Resonant Primary
NCL30086 Analog/Digital Dimmable Power Factor Corrected Quasi-Resonant Primary

AN1957
AN1957

... Another major function is Low Voltage Detect (LVD), which detects power supply brownouts and glitches. Whenever VCC falls below the Reset threshold (VRST), the Reset output is asserted and remains so trec after VCC increases above the Vrst threshold. In the case of an RC circuit, no minimum Reset pu ...
ECA - harishpola
ECA - harishpola

... collector current flow is 3600 the claa a amplifiers or furthers classified as directly coupled and transformer coupled and transformer coupled amplifiers in directly coupled type .The load is directly connected in the collector circuit while in the transformer coupled type, the load is coupled to t ...
A Complete Electrical Hazard Classification
A Complete Electrical Hazard Classification

... the development of extemal and internal capacitive discharge defibrillators resulted in substantial knowledge on the effects and injury due to capaCitor shocks in the 10 to 500 J range [25­ 29]. One study found that there was no tissue injury to dogs for any capacitive discharge under 70 J [25]. Ano ...
A Novel Multiplexer-Based Low
A Novel Multiplexer-Based Low

Features
Features

... The basic element of the UA1E family is called a cell. One cell can typically implement between one to four FPGA gates. Cells are located contiguously throughout the core of the device, with routing resources provided in three to four metal layers above the cells. Some cell blockage does occur due t ...
Applications of Op-Amps
Applications of Op-Amps

... Uses 3 vacuum tubes, only one input, and ± 350 V to attain a gain of 90 dB Loebe Julie then develops an Op-Amp with two inputs: Inverting and Non-inverting ...
– The What is an Op-Amp? Surface
– The What is an Op-Amp? Surface

BH1790GLC - ROHM Semiconductor
BH1790GLC - ROHM Semiconductor

Circuit Theorems Mustafa Kemal Uyguroğlu 1 Eastern Mediterranean University
Circuit Theorems Mustafa Kemal Uyguroğlu 1 Eastern Mediterranean University

designing concept on lightning protection of overhead power
designing concept on lightning protection of overhead power

section 16610 - uninterruptible power system
section 16610 - uninterruptible power system

... AC/DC converters. This converter is capable of full power operation in very wide input voltage range or from a nominal DC battery voltage. The energy storage stage is a split DC bus capacitor handling seamless transitions from battery to line and vice versa as well as the low and high frequency powe ...
Data Sheets
Data Sheets

... intended to operate with these low ESR capacitors, they are stable over a wide range of capacitor ESRs. Therefore, they can also work with some higher ESR tantalum or aluminum electrolytic capacitors. However, for best performance, ceramic capacitors are recommended. The value of COUT typically rang ...
Title Reference Design Report for a 150 W Power Factor Corrected
Title Reference Design Report for a 150 W Power Factor Corrected

... Thermistor RT1 provides inrush limiting. It is shorted by relay RL1 during normal operation, gated by activation of the internal bias supply (see components Q1, R20-21), increasing efficiency by approximately 1 - 1.5%. Capacitor C5 and resistor R15 are used to provide a short pulse of higher current ...
GE MagneBlast Sample Specification
GE MagneBlast Sample Specification

VOS627A Optocoupler, Phototransistor Output, AC Input, Low Input
VOS627A Optocoupler, Phototransistor Output, AC Input, Low Input

... about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specification ...
LVD - Renesas e
LVD - Renesas e

... LVIOMSK is set to 1 automatically after LVISEN =1. After rewriting LVIS, LVD detection needs stabilization. LVIOMSK =1 during rewriting LVIS and during stabilization. Therefore after clear LVISEN to 0, LVIOMSK is kept 1 during stabilization time of about 200us to ...
Electrical Safety in Grounded, Resistance Grounded and
Electrical Safety in Grounded, Resistance Grounded and

... Most technicians are very familiar with a current transformer based ground fault current relay. Even non technical personnel encounter them on a daily basis in public rest rooms protecting a wall outlet in a wet area. The operating theory behind the relay is as follows. A current transformer (CT) or ...
ZXLD1370
ZXLD1370

... 7. Device starts up above 6V and as such the minimum applied supply voltage has to be above 6.5V (plus any noise margin). The ZXLD1370 will, however, continue to function when the input voltage is reduced from ≥ 8V down to 6.3V. When operating with input voltages below 8V the output current and devi ...
Transistor as a Switch
Transistor as a Switch

... Sometimes the DC current gain of the bipolar transistor is too low to directly switch the load current or voltage, so multiple switching transistors are used. Here, one small input transistor is used to switch “ON” or “OFF” a much larger current handling output transistor. To maximise the signal gai ...
Evaluates: MAX8537 MAX8537 Evaluation Kit General Description Features
Evaluates: MAX8537 MAX8537 Evaluation Kit General Description Features

... The resistor-divider formed by R15 and R16 sets VOUT1. The MAX8537 EV kit is shipped with the divider set so VOUT1 equals 2.5V. Change the voltage by selecting R16, the resistor from FB1 to GND, between 5kΩ and 15kΩ. Then calculate R15 by: R15 = R16 x [(VOUT1 / 0.8) -1] The resistor-divider formed b ...
< 1 ... 118 119 120 121 122 123 124 125 126 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report