LT56 Series Dimming Guide
... Application Note - H277, H347 and H347200 step-down transformers are qualified to drive multiple Halo LED on a single circuit in Non-IC construction. Installation of these transformers with individual LED fixtures on circuits with multiple LED loads is not recommended. This is not recommended due t ...
... Application Note - H277, H347 and H347200 step-down transformers are qualified to drive multiple Halo LED on a single circuit in Non-IC construction. Installation of these transformers with individual LED fixtures on circuits with multiple LED loads is not recommended. This is not recommended due t ...
Mandalay Coach Electrical Modifications Manual
... This consumer unit is a standard device found in properly wired domestic premises, and it conforms to all the relevant IEEE wiring regulations as stated in Part 16 of the IEEE wiring rules. The consumer unit contains all the circuit breakers (MCBs) for the 240V mains, and the function of each is exp ...
... This consumer unit is a standard device found in properly wired domestic premises, and it conforms to all the relevant IEEE wiring regulations as stated in Part 16 of the IEEE wiring rules. The consumer unit contains all the circuit breakers (MCBs) for the 240V mains, and the function of each is exp ...
Document
... have been explored to replace Al in order to minimize wire RC delays. This could make the wire inductive reactance larger than the resistance. ...
... have been explored to replace Al in order to minimize wire RC delays. This could make the wire inductive reactance larger than the resistance. ...
UltraVolt, Inc. - Application Notes for High Voltage Power Supplies
... and are unique to each model. The HV Multiplier in each high-voltage power supply is grounded through the Rsense resistor, as shown in Figure 1. The HV Feedback resistors and the HV Test Point resistors are returned to ground and are seen by the power supply as an internal load. This internal load i ...
... and are unique to each model. The HV Multiplier in each high-voltage power supply is grounded through the Rsense resistor, as shown in Figure 1. The HV Feedback resistors and the HV Test Point resistors are returned to ground and are seen by the power supply as an internal load. This internal load i ...
Determination and Application of Practical Relaying
... maximum power transfer to that of only the line inductive reactance as described in R1.3. The relay settings must be evaluated against 115% of the highest series capacitor emergency current rating and the maximum power transfer calculated in R1.3 using the full line inductive Determination and Appli ...
... maximum power transfer to that of only the line inductive reactance as described in R1.3. The relay settings must be evaluated against 115% of the highest series capacitor emergency current rating and the maximum power transfer calculated in R1.3 using the full line inductive Determination and Appli ...
Joslyn Hi-Voltage® Capacitor Switches
... 1. To reduce losses caused by reactive load current 2. To reduce kVA demand 3. To improve voltage profile 4. To increase revenue or decrease customer energy consumption Switched capacitor banks can dramatically reduce losses caused by the reactive component of the load. The resistance of the feeder ...
... 1. To reduce losses caused by reactive load current 2. To reduce kVA demand 3. To improve voltage profile 4. To increase revenue or decrease customer energy consumption Switched capacitor banks can dramatically reduce losses caused by the reactive component of the load. The resistance of the feeder ...
CHIP TALK - Talking Electronics
... The circuits in sections 1 through 3 can be easily assembled using breadboard or stripboard and tested by a reader having just the basic skill, tools and test equipment. The stabilized power supply circuit described in part I can be used for powering most of these projects. For testing of logic circ ...
... The circuits in sections 1 through 3 can be easily assembled using breadboard or stripboard and tested by a reader having just the basic skill, tools and test equipment. The stabilized power supply circuit described in part I can be used for powering most of these projects. For testing of logic circ ...
Standard Available Coil Voltages
... Note that the 12000/14000 Series valves use some of the same class H coils as the HS/JJ/500 Series. Since the magnetic circuits external to the coil are substantially different between these two groups of valves the coil performance also differs. This means that those coils which are common to both ...
... Note that the 12000/14000 Series valves use some of the same class H coils as the HS/JJ/500 Series. Since the magnetic circuits external to the coil are substantially different between these two groups of valves the coil performance also differs. This means that those coils which are common to both ...
20 V, 500 mA, Low Noise LDO Regulator with Soft Start ADP7105
... Ratings may cause permanent damage to the product. This is a stress rating only; functional operation of the product at these or any other conditions above those indicated in the operational section of this specification is not implied. Operation beyond the maximum operating conditions for extended ...
... Ratings may cause permanent damage to the product. This is a stress rating only; functional operation of the product at these or any other conditions above those indicated in the operational section of this specification is not implied. Operation beyond the maximum operating conditions for extended ...
AN92 - Bias Voltage and Current Sense Circuits for Avalanche Photodiodes
... cates optical signal strength. This information can be combined with feedback techniques to maintain optical signal strength at an optimal level. The feedback loop’s operating characteristics can also determine if deleterious degradation of optical components has occurred, permitting corrective meas ...
... cates optical signal strength. This information can be combined with feedback techniques to maintain optical signal strength at an optimal level. The feedback loop’s operating characteristics can also determine if deleterious degradation of optical components has occurred, permitting corrective meas ...
Industrial Analog Current/ Voltage
... provide a programmable current up to Q24mA, or a voltage up to Q12V proportional to a control voltage signal. The control voltage is typically supplied by an external DAC with an output voltage range of 0 to 4.096V for the MAX15500 and 0 to 2.5V for the MAX15501. The output current and voltage are s ...
... provide a programmable current up to Q24mA, or a voltage up to Q12V proportional to a control voltage signal. The control voltage is typically supplied by an external DAC with an output voltage range of 0 to 4.096V for the MAX15500 and 0 to 2.5V for the MAX15501. The output current and voltage are s ...
ZXGD3101T8 Synchronous rectifier controller for flyback converters. Description
... 2. When, due to transformer action, the MOSFET body diode is forced to conduct there is approximately -0.6V on the Drain pin. 3. The detector outputs a positive voltage with respect to ground, this voltage is then fed to the MOSFET driver stage and current is sourced out of the GATEH pin. 4. The cur ...
... 2. When, due to transformer action, the MOSFET body diode is forced to conduct there is approximately -0.6V on the Drain pin. 3. The detector outputs a positive voltage with respect to ground, this voltage is then fed to the MOSFET driver stage and current is sourced out of the GATEH pin. 4. The cur ...
Control techniques for three-phase four
... centralized power generation plants are facing the problem of the high cost of expansion, especially in developing countries [4]. Renewable Energy Resources (RERs) can address these problems; however, in order to successfully integrate such green generation technologies into distribution networks, a ...
... centralized power generation plants are facing the problem of the high cost of expansion, especially in developing countries [4]. Renewable Energy Resources (RERs) can address these problems; however, in order to successfully integrate such green generation technologies into distribution networks, a ...
Lightning and surge protection for free field PV power plants
... German DIN EN 62305-3 standard and the CENELEC CLC/TS 50539-12 standard require safe operation of surge protective devices on the d.c. side even in case of overload. Supplement 5 of the German DIN EN 62305-3 standard includes a more detailed assessment of the lightning current distribution (computer ...
... German DIN EN 62305-3 standard and the CENELEC CLC/TS 50539-12 standard require safe operation of surge protective devices on the d.c. side even in case of overload. Supplement 5 of the German DIN EN 62305-3 standard includes a more detailed assessment of the lightning current distribution (computer ...
S225-10-5
... The 65oC rise insulation system and the sealed-tank construction allow for a BONUS CAPACITY 12% above the 55oC normal rating without loss of normal insulation life. The BONUS CAPACITY is stated on the nameplate (such as 167/187 kVA for a nominal 167 kVA regulator), and is available when the ADD-AMP ...
... The 65oC rise insulation system and the sealed-tank construction allow for a BONUS CAPACITY 12% above the 55oC normal rating without loss of normal insulation life. The BONUS CAPACITY is stated on the nameplate (such as 167/187 kVA for a nominal 167 kVA regulator), and is available when the ADD-AMP ...
Electrical ballast
An electrical ballast is a device intended to limit the amount of current in an electric circuit. A familiar and widely used example is the inductive ballast used in fluorescent lamps, to limit the current through the tube, which would otherwise rise to destructive levels due to the tube's negative resistance characteristic.Ballasts vary in design complexity. They can be as simple as a series resistor or inductor, capacitors, or a combination thereof or as complex as electronic ballasts used with fluorescent lamps and high-intensity discharge lamps.