• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
CHAPTER 8 Transmission of power
CHAPTER 8 Transmission of power

Transformers and Alternating Current
Transformers and Alternating Current

... Thomas Alva Edison had “invented” the light bulb but he needed to deliver power to the homes to light the lights. Edison had in mind to use DC. But DC power had a lot of problems: it could not travel long distances, it required very thick wires, its voltage could not be easily, etc. Nikola Tesla, wh ...
FPF2165R Full Function Load Switch with Adjustable Current Limit Features
FPF2165R Full Function Load Switch with Adjustable Current Limit Features

... doesn't exceed a maximum value while not limiting at less than a minimum value. The current at which the parts will limit is adjustable through the selection of an external resistor connected to ISET. Information for selecting the resistor is found in the Application Info section. The FPF2165R has n ...
1951 , Volume v.2 n.10 , Issue June-1951
1951 , Volume v.2 n.10 , Issue June-1951

... and by relating the reference volt ages for the amplitude comparators to the same voltages used in the clamping. Thus, a change in clamp ing voltage will modify the ampli tude of the square wave, but the ref erence voltages for the amplitudecomparators will also be modified by the same percentage. T ...
GT3412451250
GT3412451250

... proposed to balance the generator output power to control the generator voltage [1], [7], [8]. However, since the active power is controlled with a variable ac/dc load in the ELC, the system efficiency is low [9]. For the wind-driven SEIG where wind speed and consumer loads are variable, both input ...
FR011L5J (11mΩ, -30V) Low-Side Reverse Bias / Reverse Polarity Protector FR011L
FR011L5J (11mΩ, -30V) Low-Side Reverse Bias / Reverse Polarity Protector FR011L

... qualification devices, where the predicted failure rate is less than 0.01% at the specified voltage for 24 hours. It is intended to indicate the device’s ability to withstand transient events that exceed the recommended operating voltage rating. Specification is based on qualification devices tested ...
Parallel Circuits
Parallel Circuits

... 5-1: The Applied Voltage VA Is the Same Across Parallel Branches  Characteristics of a Parallel Circuit  Voltage is the same across each branch in a parallel circuit.  The total current is equal to the sum of the individual branch currents.  The equivalent resistance (REQ) is less than the smal ...
Immersion Heater Controller
Immersion Heater Controller

... Ok, the Triac (ST’s BTA20) is the power device which will switch on and off at different intervals synchronized to the mains. It is this which will let current flow through the load, which in our case, is the immersion heater (approximately 18 Ohms). By firing the triac for different lengths of time ...
KB2517721780
KB2517721780

Course Structure
Course Structure

... guarantee is made to resource thoroughness, statutory or regulatory compliance, and related media may depict situations that are not in compliance with OSHA and other safety requirements. It is the responsibility of educators/employers and their students/employees, or anybody using our resources, to ...
Electricity generators
Electricity generators

... the generator is connected. DC generators are usually operated at fairly low voltages to avoid the sparking between brushes and commutator that occurs at high voltage. The highest potential commonly developed by such generators is 1500 V. In some newer machines this reversal is accomplished using po ...
Finite Set-Model Predictive Current Control of Three
Finite Set-Model Predictive Current Control of Three

... flexibility of MPC for their application. In this paper, an FS-MPC for three-phase two-level VSI with resistive-inductive load supplied by a renewable energy system (wind and PV) is presented. The powerful and robustness of the proposed control method are evaluated through simulations results. Secti ...
MATERIAL SPECIFICATION FOR FLOODLIGHT LUMINAIRES
MATERIAL SPECIFICATION FOR FLOODLIGHT LUMINAIRES

... Documents as the Owner invokes them. Invoking a particular appendix does not obligate an Owner to use all available appendices. Only invoked appendices form part of the Contract Documents. The decision to use any appendix is determined by an Owner after considering their contract requirements and th ...
EEEE 482 Lab1 Rev2015_1 - RIT
EEEE 482 Lab1 Rev2015_1 - RIT

... for a differential amplifier (Figure 2) with a differential gain of 80 V/V (  10%), assuming a current source of 6 mA as shown. Note that this target gain is from the base of Q3 to the output vo, not from vsig to vo. (You must calculate the value of RC3 (= RC4) and round resistor values to nearest ...
AEMC Single-Phase Power Quality Analyzer AEMC Power Quality
AEMC Single-Phase Power Quality Analyzer AEMC Power Quality

... • Monitor demand at 15 minute or user-defined averaging periods • Verify efficiency improvements with energy consumption tests • Measure harmonic distortion caused by electronic loads • Capture voltage dips and swells from load switching • Easily confirm instrument setup with color display of wavefo ...
A NOVELL METHOD OF ELECTRONIC TECHNIQUES FOR SOLVING HIGH
A NOVELL METHOD OF ELECTRONIC TECHNIQUES FOR SOLVING HIGH

... inputs of OPA, the Voltage over shunt and the currentoutput on RL. ...
Development of a Compact Three-Phase Induction Motor Drive
Development of a Compact Three-Phase Induction Motor Drive

... motor drives course. The induction motor is essentially a constant speed machine if a constant voltage and frequency source is connected [1]. When the load torque increases, the induction motor speed drop will be minimal, which is the advantage for the constant speed applications. Many single chip m ...
Fluke Power Logger - Weschler Instruments
Fluke Power Logger - Weschler Instruments

A Solid State Opening Switch and Mod Anode Supply for the
A Solid State Opening Switch and Mod Anode Supply for the

Immersion Heater controller
Immersion Heater controller

... Ok, the Triac (ST’s BTA20) is the power device which will switch on and off at different intervals synchronized to the mains. It is this which will let current flow through the load, which in our case, is the immersion heater (approximately 18 Ohms). By firing the triac for different lengths of time ...
PDF Karta katalogowa
PDF Karta katalogowa

... The PFS 200N is a standalone tester providing an electronic switch to perform voltage dips and drops (micro-interruptions) with fast rise and fall times of 1 microsecond. For voltage dips two DC voltage supplies are required while for for voltage drops (micro-interruptions) only one DC voltage suppl ...
load- and test resistors
load- and test resistors

... Continuous operation outputs of several megawatts as well as special designs can also be realised. The devices which are customer-specific in almost all cases can be equipped with any kind of step circuit, regulation, measurement and control. ...
FOG-901 and FOG-901NP Momentary Switch to
FOG-901 and FOG-901NP Momentary Switch to

... and wiring loom cost. The units also feature three ‘enable’ inputs which control the operation of the module. The FOG-901 or FOG-901NP will be inactive until at least one of these enable inputs is connected to +12V, at which time the unit can be controlled with the pushbutton. If all the enable inpu ...
U sing and Understanding MINIATURE NEON LAMPS
U sing and Understanding MINIATURE NEON LAMPS

... current, it will give over a million hours of use before darkening restricts its light output by 50 percent. Neon lamps perform poorly a t altitudes higher than 70,000 feet, where the lower atmospheric pressures encourage external corona and arcing. The tungsten-filament lamp can produce high light ...
S. Gunter, K.K. Afridi, D.M. Otten, R. Abramson, and D.J. Perreault, “Impedance Control Network Resonant Step-Down DC-DC Converter Architecture,” 2015 Energy Conversion Congress and Exposition , pp. 539-547, Sept. 2015.
S. Gunter, K.K. Afridi, D.M. Otten, R. Abramson, and D.J. Perreault, “Impedance Control Network Resonant Step-Down DC-DC Converter Architecture,” 2015 Energy Conversion Congress and Exposition , pp. 539-547, Sept. 2015.

... is tied to both the circuit design and the control methodology. A. Frequency Control One common technique used to enable soft-switching in resonant converters (e.g., series, parallel, series-parallel, LLC converters, etc.) is through frequency control. By modulating the converter switching frequency ...
< 1 ... 367 368 369 370 371 372 373 374 375 ... 947 >

Electrical ballast



An electrical ballast is a device intended to limit the amount of current in an electric circuit. A familiar and widely used example is the inductive ballast used in fluorescent lamps, to limit the current through the tube, which would otherwise rise to destructive levels due to the tube's negative resistance characteristic.Ballasts vary in design complexity. They can be as simple as a series resistor or inductor, capacitors, or a combination thereof or as complex as electronic ballasts used with fluorescent lamps and high-intensity discharge lamps.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report