SMP18
... supplies over a voltage range of 7 to 15 volts. Based on the supply voltages chosen, VDD and VSS establish the output voltage range, which is: ...
... supplies over a voltage range of 7 to 15 volts. Based on the supply voltages chosen, VDD and VSS establish the output voltage range, which is: ...
LTC3216 - 1A Low Noise High Current LED Charge Pump with
... current to the LTC3216 will be relatively constant while the charge pump is on either the input charging phase or the output charging phase but will drop to zero during the clock nonoverlap times. Since the nonoverlap time is small (~15ns), these missing “notches” will result in only a small perturb ...
... current to the LTC3216 will be relatively constant while the charge pump is on either the input charging phase or the output charging phase but will drop to zero during the clock nonoverlap times. Since the nonoverlap time is small (~15ns), these missing “notches” will result in only a small perturb ...
MWPR1516 16 KB Flash - Freescale Semiconductor
... 5. Input must be current limited to the value specified. To determine the value of the required current-limiting resistor, calculate resistance values for positive and negative clamp voltages, then use the large one. 6. Power supply must maintain regulation within operating VDD range during instanta ...
... 5. Input must be current limited to the value specified. To determine the value of the required current-limiting resistor, calculate resistance values for positive and negative clamp voltages, then use the large one. 6. Power supply must maintain regulation within operating VDD range during instanta ...
Evaluation Board User Guide UG-310
... PWM mode selected, the switching frequency is set to 500 kHz. Different output voltage settings and configurations can be achieved by changing appropriate passive components or jumper settings. The ambient temperature operating range is −40°C to +85°C. Full details on the ADP2323 dual regulator are ...
... PWM mode selected, the switching frequency is set to 500 kHz. Different output voltage settings and configurations can be achieved by changing appropriate passive components or jumper settings. The ambient temperature operating range is −40°C to +85°C. Full details on the ADP2323 dual regulator are ...
Data Sheet - Energy Recovery Products
... ERP - Energy Recovery Products (ERP Power, LLC) - reserves the right to make changes without further noNce to any products herein. ERP makes no warranty, representaNon or guarantee regarding the suitability of its products for any parNcular purpose, nor does ERP assume any liability arising out of ...
... ERP - Energy Recovery Products (ERP Power, LLC) - reserves the right to make changes without further noNce to any products herein. ERP makes no warranty, representaNon or guarantee regarding the suitability of its products for any parNcular purpose, nor does ERP assume any liability arising out of ...
Triode Electronics Dynaco ST
... This indicates either a restriction in the power supply such as open windings in the power transformer or choke, or a bad rectifier tube, or excessive current draw. Excessive current draw can be caused by shorted output transformers, bad output tubes, leaky coupling capacitors, or leaky filter capac ...
... This indicates either a restriction in the power supply such as open windings in the power transformer or choke, or a bad rectifier tube, or excessive current draw. Excessive current draw can be caused by shorted output transformers, bad output tubes, leaky coupling capacitors, or leaky filter capac ...
LT1787/LT1787HV - Precision, High Side Current Sense Amplifiers
... side current sense amplifier. The LT1787 monitors bidirectional currents via the voltage across an external sense resistor. A current or voltage output indicates the direction and magnitude of the sense current. The LT1787 delivers greater than a 12-bit dynamic range with ultralow 40µV input offset ...
... side current sense amplifier. The LT1787 monitors bidirectional currents via the voltage across an external sense resistor. A current or voltage output indicates the direction and magnitude of the sense current. The LT1787 delivers greater than a 12-bit dynamic range with ultralow 40µV input offset ...
Here
... uncertainty conditions. Reference [3] research work has been done in GSM based fully automated system in power transformer. To operate a power distribution system with a transformer out of service is always very difficult. The impact of a transformer fault is more serious than a transmission line ou ...
... uncertainty conditions. Reference [3] research work has been done in GSM based fully automated system in power transformer. To operate a power distribution system with a transformer out of service is always very difficult. The impact of a transformer fault is more serious than a transmission line ou ...
MAX629 28V, Low-Power, High-Voltage, Boost or Inverting DC
... inductor current, but may limit output current capability at low input voltages and provide slower start-up times. Smaller inductances require less board space, but may cause greater peak current due to current-sense comparator propagation delay. If input voltages below 2V will be common, reducing t ...
... inductor current, but may limit output current capability at low input voltages and provide slower start-up times. Smaller inductances require less board space, but may cause greater peak current due to current-sense comparator propagation delay. If input voltages below 2V will be common, reducing t ...
Integration of Distributed Generation in Low Voltage Networks
... conditions that are out of the normal operating range can lead to poor operation of the power system and customer loads, damage to utility equipment and customer loads, and in extreme cases can even be a safety hazard. Generally speaking, utilities strive to meet the standard European voltage limits ...
... conditions that are out of the normal operating range can lead to poor operation of the power system and customer loads, damage to utility equipment and customer loads, and in extreme cases can even be a safety hazard. Generally speaking, utilities strive to meet the standard European voltage limits ...
MAX5188/MAX5191 Dual, 8-Bit, 40MHz, Current/Voltage, Alternate-Phase Output DACs General Description
... speeds up to 40MHz. Each of these dual converters consists of separate input and DAC registers, followed by a current-source array capable of generating up to 1.5mA full-scale output current (Figure 1). An integrated +1.2V voltage reference and control amplifier determine the data converters’ full-s ...
... speeds up to 40MHz. Each of these dual converters consists of separate input and DAC registers, followed by a current-source array capable of generating up to 1.5mA full-scale output current (Figure 1). An integrated +1.2V voltage reference and control amplifier determine the data converters’ full-s ...
BD8143MUV : Power Management ICs
... The OSC generates the frequency that determines the Amp's refresh time. External input can be selected using serial input. ・Power On Reset When the digital power supply DVCC is activated, each IC generates a reset signal to initialize the serial interface, registers. Adding a 1,000 pF capacitor to t ...
... The OSC generates the frequency that determines the Amp's refresh time. External input can be selected using serial input. ・Power On Reset When the digital power supply DVCC is activated, each IC generates a reset signal to initialize the serial interface, registers. Adding a 1,000 pF capacitor to t ...
VF-0 series - Panasonic Electric Works
... MN for 60s) and has low level open-circuit power consumption. This function is particularly useful for drives with strong fluctuating loads or high starting inertia, as well as for sensorless speed control of motors requiring slip compensation. ...
... MN for 60s) and has low level open-circuit power consumption. This function is particularly useful for drives with strong fluctuating loads or high starting inertia, as well as for sensorless speed control of motors requiring slip compensation. ...
Electrical ballast
An electrical ballast is a device intended to limit the amount of current in an electric circuit. A familiar and widely used example is the inductive ballast used in fluorescent lamps, to limit the current through the tube, which would otherwise rise to destructive levels due to the tube's negative resistance characteristic.Ballasts vary in design complexity. They can be as simple as a series resistor or inductor, capacitors, or a combination thereof or as complex as electronic ballasts used with fluorescent lamps and high-intensity discharge lamps.