BQ24450 数据资料 dataSheet 下载
... the IC to implement a charger for sealed lead-acid batteries. The IC's internal driver transistor Q1 (see Figure 1) supports NPN as well as PNP pass transistors, and provides enough drive current (25mA specified) to support a wide range of charging rates. The driver transistor is controlled by a vol ...
... the IC to implement a charger for sealed lead-acid batteries. The IC's internal driver transistor Q1 (see Figure 1) supports NPN as well as PNP pass transistors, and provides enough drive current (25mA specified) to support a wide range of charging rates. The driver transistor is controlled by a vol ...
Data Sheet
... Should by any chance the power dissipation rating be exceeded the rise in temperature of the chip may result in deterioration of the properties of the chip. In case of exceeding this absolute maximum rating, increase the board size and copper area to prevent exceeding the Pd rating. ...
... Should by any chance the power dissipation rating be exceeded the rise in temperature of the chip may result in deterioration of the properties of the chip. In case of exceeding this absolute maximum rating, increase the board size and copper area to prevent exceeding the Pd rating. ...
LTC3550-1
... current to maintain a constant die temperature during high power operation or high ambient temperature conditions. The float voltage is fixed at 4.2V and the charge currents are programmed with external resistors. The LTC3550-1 terminates the charge cycle when the charge current drops below the progra ...
... current to maintain a constant die temperature during high power operation or high ambient temperature conditions. The float voltage is fixed at 4.2V and the charge currents are programmed with external resistors. The LTC3550-1 terminates the charge cycle when the charge current drops below the progra ...
UPG2024TQ - California Eastern Laboratories
... exempted from the requirement of RoHS directive (*). In all cases the devices have Pb-free terminals. All devices with these suffixes meet the requirements of the RoHS directive. This status is based on CEL’s understanding of the EU Directives and knowledge of the materials that go into its products ...
... exempted from the requirement of RoHS directive (*). In all cases the devices have Pb-free terminals. All devices with these suffixes meet the requirements of the RoHS directive. This status is based on CEL’s understanding of the EU Directives and knowledge of the materials that go into its products ...
isscc 2013 / session 24 / energy
... tree is also implemented for comparison, since clocking with an unbuffered tree is more energy-efficient than that with a buffered tree in near/sub-Vt circuits [7]. Figures 24.9.4 (a) and (b) show conventional non-resonant clocking and the proposed IRC, respectively. For a fair power comparison, the ...
... tree is also implemented for comparison, since clocking with an unbuffered tree is more energy-efficient than that with a buffered tree in near/sub-Vt circuits [7]. Figures 24.9.4 (a) and (b) show conventional non-resonant clocking and the proposed IRC, respectively. For a fair power comparison, the ...
F`MONOSTABLE I] \/
... is manually set With the tuning control 6. The supply voltage for the generator 6 is derived, through the resistive divider 10, from the output of the poWer supply 12, labeled “PWR”, ...
... is manually set With the tuning control 6. The supply voltage for the generator 6 is derived, through the resistive divider 10, from the output of the poWer supply 12, labeled “PWR”, ...
eet 3086 power transmission and distribution
... INITIATE FAULT button………………………………………………….released position FAULT DURATION switch……………………………………………………….0.05 – 5 s Make sure that the current transformers are connected as shown in Figure 3 then set the switches of current transformers CT4, CT5, and CT6 on the current transformers module to the O (ope ...
... INITIATE FAULT button………………………………………………….released position FAULT DURATION switch……………………………………………………….0.05 – 5 s Make sure that the current transformers are connected as shown in Figure 3 then set the switches of current transformers CT4, CT5, and CT6 on the current transformers module to the O (ope ...
Equal-Area Criterion Applied on Power Transfer Corridors
... fulfil the equal-area criterion, several studies focus on the identification of critical machines which are likely to loose synchronism with the remaining system [5-13]. In the case with multiple critical machines, it is possible to cluster these into an equivalent one-machine-infinite-bus (OMIB) sy ...
... fulfil the equal-area criterion, several studies focus on the identification of critical machines which are likely to loose synchronism with the remaining system [5-13]. In the case with multiple critical machines, it is possible to cluster these into an equivalent one-machine-infinite-bus (OMIB) sy ...
Low Frequency Sounder/Strobes
... DC or FWR (full wave rectified) systems. Sounder/Strobe versions are only to be used with 24 volt, DC or FWR systems. These products are electrically backward compatible with the previous generation of SpectrAlert notification appliances. The 2-wire products fit systems where a single NAC controls b ...
... DC or FWR (full wave rectified) systems. Sounder/Strobe versions are only to be used with 24 volt, DC or FWR systems. These products are electrically backward compatible with the previous generation of SpectrAlert notification appliances. The 2-wire products fit systems where a single NAC controls b ...
UCCx813-x Low-Power Economy BiCMOS
... Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absol ...
... Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absol ...
SBS 1.1-COMPLIANT FUEL GAUGE WITH
... DQ communication interfaces are both available. Together with the integrated analog front-end (AFE) short-circuit and overload protection, the bq34z950 maximizes functionality and safety while minimizing external component count, cost, and size in smart battery circuits. The implemented Impedance Tr ...
... DQ communication interfaces are both available. Together with the integrated analog front-end (AFE) short-circuit and overload protection, the bq34z950 maximizes functionality and safety while minimizing external component count, cost, and size in smart battery circuits. The implemented Impedance Tr ...
MAX17595/MAX17596/MAX17597 Peak-Current-Mode Controllers for Flyback and Boost Regulators General Description
... an internal error amplifier with 1% accurate reference, eliminating the need for an external reference. The switching frequency is programmable from 100kHz to 1MHz with an accuracy of 8% , allowing optimization of magnetic and filter components, resulting in compact and cost-effective power conversi ...
... an internal error amplifier with 1% accurate reference, eliminating the need for an external reference. The switching frequency is programmable from 100kHz to 1MHz with an accuracy of 8% , allowing optimization of magnetic and filter components, resulting in compact and cost-effective power conversi ...
Multi-Output Power Supplies with VCOM Amplifier and High
... The MAX17126B generates all the supply rails for thinfilm transistor liquid-crystal display (TFT LCD) TV panels operating from a regulated 12V input. They include a step-down and a step-up regulator, a positive and a negative charge pump, an operational amplifier, a highaccuracy high-voltage gamma r ...
... The MAX17126B generates all the supply rails for thinfilm transistor liquid-crystal display (TFT LCD) TV panels operating from a regulated 12V input. They include a step-down and a step-up regulator, a positive and a negative charge pump, an operational amplifier, a highaccuracy high-voltage gamma r ...
Diesel-Electric Propulsion Systems
... are based on the principle of speed controlled AC or DC motors driving the propeller directly or by gearing. The most reliable and low noise design is the direct drive. Electric propulsion systems are designed according to the „power station principle“. That means that under normal conditions all al ...
... are based on the principle of speed controlled AC or DC motors driving the propeller directly or by gearing. The most reliable and low noise design is the direct drive. Electric propulsion systems are designed according to the „power station principle“. That means that under normal conditions all al ...
MPC941 rev 10 Final Data Sheet.fm
... In equation 2, P stands for the number of outputs with a parallel or thevenin termination. VOL, IOL, VOH and IOH are a function of the output termination technique, and DCQ is the clock signal duty cyle. If transmission lines are used, CL is zero in equation 2 and can be eliminated. In general, the ...
... In equation 2, P stands for the number of outputs with a parallel or thevenin termination. VOL, IOL, VOH and IOH are a function of the output termination technique, and DCQ is the clock signal duty cyle. If transmission lines are used, CL is zero in equation 2 and can be eliminated. In general, the ...
MUSICAL INSTRUMENTS
... 9 V outputs to increase the current intensity to a massive 500 mA, the other one, with a white connector, connects two 9 V outputs to double the voltage to 18 V.. Also included is a 1-into5 daisy chain that lets you power five pedals from one output if their total current draw does not exceed 250 mA ...
... 9 V outputs to increase the current intensity to a massive 500 mA, the other one, with a white connector, connects two 9 V outputs to double the voltage to 18 V.. Also included is a 1-into5 daisy chain that lets you power five pedals from one output if their total current draw does not exceed 250 mA ...
EGEE
... The need for a magnetic field tolerant converter imposes the use of an air-core (or coreless) inductor, limiting the available inductance value to below about 700nH. This imposes a switching frequency of 1-4MHz, which is beyond typical converter implementations. To efficiently drive the switches at ...
... The need for a magnetic field tolerant converter imposes the use of an air-core (or coreless) inductor, limiting the available inductance value to below about 700nH. This imposes a switching frequency of 1-4MHz, which is beyond typical converter implementations. To efficiently drive the switches at ...
OPA660 Wide Bandwidth OPERATIONAL TRANSCONDUCTANCE
... It is also possible to vary the quiescent current with a control signal. The control loop in Figure 3 shows a 1/2 of a REF200 current source used to develop 100mV on R1. The loop forces 100mV to appear on R2. Total quiescent current of the OPA660 is approximately 85 • I1, where I1 is the current mad ...
... It is also possible to vary the quiescent current with a control signal. The control loop in Figure 3 shows a 1/2 of a REF200 current source used to develop 100mV on R1. The loop forces 100mV to appear on R2. Total quiescent current of the OPA660 is approximately 85 • I1, where I1 is the current mad ...
2014 Connecting of Meters - Schuylkill Technology Center
... 2. Locates overloads and open circuits 3. Balances the loads on multiwire circuits 4. Locates electrical component malfunctions 5. Two types a. In-line In-line ammeters should always be connected in series with the circuit or component being tested. If direct current is being measured, always check ...
... 2. Locates overloads and open circuits 3. Balances the loads on multiwire circuits 4. Locates electrical component malfunctions 5. Two types a. In-line In-line ammeters should always be connected in series with the circuit or component being tested. If direct current is being measured, always check ...
Half stepping techniques
... The first part shows the two-phase-on drive where the motor steps from pos 1 to 3, 5, 7. In the second part of the diagram, a half step sequence is fed into the windings. Compared to full-step drive, half-step drive gives some major advantages: • Higher resolution (without use of a more expensive mo ...
... The first part shows the two-phase-on drive where the motor steps from pos 1 to 3, 5, 7. In the second part of the diagram, a half step sequence is fed into the windings. Compared to full-step drive, half-step drive gives some major advantages: • Higher resolution (without use of a more expensive mo ...
CP2102 - Sparkfun
... resulting from the use of information included herein. Additionally, Silicon Laboratories assumes no responsibility for the functioning of undescribed features or parameters. Silicon Laboratories reserves the right to make changes without further notice. Silicon Laboratories makes no warranty, repre ...
... resulting from the use of information included herein. Additionally, Silicon Laboratories assumes no responsibility for the functioning of undescribed features or parameters. Silicon Laboratories reserves the right to make changes without further notice. Silicon Laboratories makes no warranty, repre ...
WATER COOLED POWER TETRODE 8974
... should be smoothly increased from zero to the operating level over a period of two minutes, and a motordriven continuously variable auto-transformer (such as a VARIAC* or a POWERSTAT*) is suggested. Normal turnoff procedure should be a smooth decrease from the operating voltage to zero over a period ...
... should be smoothly increased from zero to the operating level over a period of two minutes, and a motordriven continuously variable auto-transformer (such as a VARIAC* or a POWERSTAT*) is suggested. Normal turnoff procedure should be a smooth decrease from the operating voltage to zero over a period ...
high voltage direct current power transmission
... converted to DC in a converter station, transmitted to the receiving point by an overhead line or cable and then converted back to AC in another converter station and injected into the receiving AC network. ...
... converted to DC in a converter station, transmitted to the receiving point by an overhead line or cable and then converted back to AC in another converter station and injected into the receiving AC network. ...
Power inverter
A power inverter, or inverter, is an electronic device or circuitry that changes direct current (DC) to alternating current (AC).The input voltage, output voltage and frequency, and overall power handling depend on the design of the specific device or circuitry. The inverter does not produce any power; the power is provided by the DC source.A power inverter can be entirely electronic or may be a combination of mechanical effects (such as a rotary apparatus) and electronic circuitry.Static inverters do not use moving parts in the conversion process.