MAX961–MAX964/ MAX997/MAX999 Single/Dual/Quad, Ultra
... The MAX961–MAX964/MAX997/MAX999 are low-power, ultra-high-speed comparators with internal hysteresis. These devices are optimized for single +3V or +5V operation. The input common-mode range extends 100mV Beyond-theRails™, and the outputs can sink or source 4mA to within 0.52V of GND and VCC. Propag ...
... The MAX961–MAX964/MAX997/MAX999 are low-power, ultra-high-speed comparators with internal hysteresis. These devices are optimized for single +3V or +5V operation. The input common-mode range extends 100mV Beyond-theRails™, and the outputs can sink or source 4mA to within 0.52V of GND and VCC. Propag ...
DESCRIPTION FEATURES ULTRA-PRECISION DIFFERENTIAL
... The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use. Micrel reserves the right to change circuitry and specifications at any time without notification to the customer. Micrel Products are not desi ...
... The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use. Micrel reserves the right to change circuitry and specifications at any time without notification to the customer. Micrel Products are not desi ...
Modeling of Multi-Pulse VSC Based SSSC and STATCOM
... Figure 1 results in phase, va6, and line, vab6, voltages for phase a like the ones exhibited in Figure 3. The harmonic components of these signals are in the order of n = 6m ± 1, where m = 0,1,2, …, and the peak amplitude of the fundamental and harmonic components of va6 and vab6 are given by va6n = ...
... Figure 1 results in phase, va6, and line, vab6, voltages for phase a like the ones exhibited in Figure 3. The harmonic components of these signals are in the order of n = 6m ± 1, where m = 0,1,2, …, and the peak amplitude of the fundamental and harmonic components of va6 and vab6 are given by va6n = ...
36-V, Prog.-Gain, Voltage-Output, Bidir, Zero
... Four discrete gain levels are selectable using the two gain-select terminals (GS0 and GS1) to program gains of 25 V/V, 50 V/V, 100 V/V, and 200 V/V. The low-offset, zero-drift architecture and precision gain values enable current-sensing with maximum drops across the shunt as low as 10 mV of full-sc ...
... Four discrete gain levels are selectable using the two gain-select terminals (GS0 and GS1) to program gains of 25 V/V, 50 V/V, 100 V/V, and 200 V/V. The low-offset, zero-drift architecture and precision gain values enable current-sensing with maximum drops across the shunt as low as 10 mV of full-sc ...
ECE 431 Electric Machines Lab Manual
... 2/3 of all electrical energy is delivered to electric machinery, and nearly 100% is produced by machines. It is well known that growth in electrical energy production has been closely correlated with economic growth in nearly all countries over the past several decades. The reasons are not just thos ...
... 2/3 of all electrical energy is delivered to electric machinery, and nearly 100% is produced by machines. It is well known that growth in electrical energy production has been closely correlated with economic growth in nearly all countries over the past several decades. The reasons are not just thos ...
Distribution Systems, Substations, and Integration of Distributed
... customer. This system provides the safe and reliable transfer of electric energy to various customers throughout the service territory. Typical distribution systems begin as the medium-voltage three-phase circuit, typically about 30–60 kV, and terminate at a lower secondary three- or single-phase vo ...
... customer. This system provides the safe and reliable transfer of electric energy to various customers throughout the service territory. Typical distribution systems begin as the medium-voltage three-phase circuit, typically about 30–60 kV, and terminate at a lower secondary three- or single-phase vo ...
MAX1778/ MAX1880–MAX1885 Quad-Output TFT LCD DC-DC Converters with Buffer
... The main step-up converter accurately generates an externally set output voltage up to 13V that can supply the display’s row/column drivers. The converter’s high switching frequency and current-mode PWM architecture provide fast transient response and allow the use of small low-profile inductors and ...
... The main step-up converter accurately generates an externally set output voltage up to 13V that can supply the display’s row/column drivers. The converter’s high switching frequency and current-mode PWM architecture provide fast transient response and allow the use of small low-profile inductors and ...
AC Sources - Operating 3.8.1 3.8 ELECTRICAL POWER SYSTEMS
... ------------------------------NOTES-----------------------------1. Momentary transients outside the load and power factor ranges do not invalidate this test. 2. If performed with EDG synchronized with offsite power, it shall be performed at a power factor ≤ 0.9. However, if grid conditions do not pe ...
... ------------------------------NOTES-----------------------------1. Momentary transients outside the load and power factor ranges do not invalidate this test. 2. If performed with EDG synchronized with offsite power, it shall be performed at a power factor ≤ 0.9. However, if grid conditions do not pe ...
Linear Transverters for 144 and 220 Mhz
... transverter interconnecting cables, interfering with signals being received from 220 MHz. Also, when more than one transverter with a 28-MHz IF is operated in the same room (at a multioperator VHF contest station, for example), it is not uncommon to hear signals from the other IF transceivers. Oscil ...
... transverter interconnecting cables, interfering with signals being received from 220 MHz. Also, when more than one transverter with a 28-MHz IF is operated in the same room (at a multioperator VHF contest station, for example), it is not uncommon to hear signals from the other IF transceivers. Oscil ...
MAX14838/9 - Maxim Part Number Search
... the absolute maximum rating of the VCC pin occur during ESD, burst, and hot plug events. The MAX14838/ MAX14839 cannot be damaged with a 100nF bypass capacitor on the VCC line. Transients due to inductive kickback on DO when driving inductive loads up to 1.5H at 100mA or less can also bring the DO v ...
... the absolute maximum rating of the VCC pin occur during ESD, burst, and hot plug events. The MAX14838/ MAX14839 cannot be damaged with a 100nF bypass capacitor on the VCC line. Transients due to inductive kickback on DO when driving inductive loads up to 1.5H at 100mA or less can also bring the DO v ...
CGR-0118Z DUAL CATV 5MHz to 65MHz CATV AMP IC Features Product Description
... Exposed area on the bottom side of the package must be soldered to the ground plane of hte board for optimum thermal and RF performance. Several vias should be located under the EPAD as shown in the recommended land pattern. ...
... Exposed area on the bottom side of the package must be soldered to the ground plane of hte board for optimum thermal and RF performance. Several vias should be located under the EPAD as shown in the recommended land pattern. ...
AL5811 Description Pin Assignments
... 2. support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in significant injury to the user. B. A critical component is any component in a life support device or system whose failur ...
... 2. support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in significant injury to the user. B. A critical component is any component in a life support device or system whose failur ...
list of tables - Sacramento - California State University
... sun by using photoresistor sensors. Batteries will be used and efficiently maintained by solar energy and a control circuit to protect the battery from over and under charging. Because the main system components will be selected based on both cost and efficiency, these characteristics will be carefu ...
... sun by using photoresistor sensors. Batteries will be used and efficiently maintained by solar energy and a control circuit to protect the battery from over and under charging. Because the main system components will be selected based on both cost and efficiency, these characteristics will be carefu ...
R225-01-1
... Figure 2C shows the neutral shift resulting from the third bank of regulators. Phases VAB and VAC adjust when the voltage regulators change tap position. However, the angle of this shift is 120° with respect to both of the initial shifts from bank one and bank two. The result is a cancellation of th ...
... Figure 2C shows the neutral shift resulting from the third bank of regulators. Phases VAB and VAC adjust when the voltage regulators change tap position. However, the angle of this shift is 120° with respect to both of the initial shifts from bank one and bank two. The result is a cancellation of th ...
LMC6482 - UTK-EECS
... Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is intended to be functional, but specific performance is not ensured. For ensured specifications and the test conditions, see the Electrical Characteristi ...
... Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is intended to be functional, but specific performance is not ensured. For ensured specifications and the test conditions, see the Electrical Characteristi ...
MAX9674 Evaluation Kit Evaluates: General Description Features
... The MAX9674 EV kit demonstrates the MAX9674 reference voltage generator for gamma correction in TFTLCD panels, such as those found in high-resolution TVs and high-end monitors, or for general-purpose industrial reference voltage generation. The EV kit provides a total of 17 programmable 10-bit-resol ...
... The MAX9674 EV kit demonstrates the MAX9674 reference voltage generator for gamma correction in TFTLCD panels, such as those found in high-resolution TVs and high-end monitors, or for general-purpose industrial reference voltage generation. The EV kit provides a total of 17 programmable 10-bit-resol ...
MAX9377/MAX9378 Anything-to-LVPECL/LVDS Translators with Pin-Selectable Divide-by-Four General Description
... Outputs are placed in differential low. ...
... Outputs are placed in differential low. ...
AN-272 Op Amp Booster Designs (Rev. B)
... 300W for positive outputs up to a staggering 1000V. This performance is achieved without sacrificing efficiency because this booster, in contrast to all the others shown, operates in a switching mode. In addition, this booster runs off ±15V supplies and has the highly desirable property of not requi ...
... 300W for positive outputs up to a staggering 1000V. This performance is achieved without sacrificing efficiency because this booster, in contrast to all the others shown, operates in a switching mode. In addition, this booster runs off ±15V supplies and has the highly desirable property of not requi ...
Presentation DC-UPS Line
... cell). Below this level the device automatically switches off to prevent Deep discharge and battery damage. ...
... cell). Below this level the device automatically switches off to prevent Deep discharge and battery damage. ...
Aalborg Universitet
... A novel Insulated Gate Bipolar Transistor (IGBT) electrothermal modeling approach involving PSpice and ANSYS/Icepak with both high accuracy and simulation speed has been presented to study short-circuit of a 1.7 kV/1 kA commercial IGBT module. The approach successfully predicts the current and tempe ...
... A novel Insulated Gate Bipolar Transistor (IGBT) electrothermal modeling approach involving PSpice and ANSYS/Icepak with both high accuracy and simulation speed has been presented to study short-circuit of a 1.7 kV/1 kA commercial IGBT module. The approach successfully predicts the current and tempe ...
AC Sources - Operating 3.8.1 3.8 ELECTRICAL POWER SYSTEMS
... ------------------------------NOTES-----------------------------1. Momentary transients outside the load and power factor ranges do not invalidate this test. 2. If performed with EDG synchronized with offsite power, it shall be performed at a power factor ≤ 0.9. However, if grid conditions do not pe ...
... ------------------------------NOTES-----------------------------1. Momentary transients outside the load and power factor ranges do not invalidate this test. 2. If performed with EDG synchronized with offsite power, it shall be performed at a power factor ≤ 0.9. However, if grid conditions do not pe ...
VIII .Typical Transmission Line Surge Arrester Installation
... each other. Their diameter decisively determines the energy absorption and the current carrying capability. It is within a range of about 30 mm when used for distribution system, and up to 100 mm or more for high-voltage and extra-high voltage system. Metal-Oxide resistors vary in height between 20 ...
... each other. Their diameter decisively determines the energy absorption and the current carrying capability. It is within a range of about 30 mm when used for distribution system, and up to 100 mm or more for high-voltage and extra-high voltage system. Metal-Oxide resistors vary in height between 20 ...
Power inverter
A power inverter, or inverter, is an electronic device or circuitry that changes direct current (DC) to alternating current (AC).The input voltage, output voltage and frequency, and overall power handling depend on the design of the specific device or circuitry. The inverter does not produce any power; the power is provided by the DC source.A power inverter can be entirely electronic or may be a combination of mechanical effects (such as a rotary apparatus) and electronic circuitry.Static inverters do not use moving parts in the conversion process.