• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Connecting Outputs in Series to Achieve High Voltage Transients
Connecting Outputs in Series to Achieve High Voltage Transients

... Due to the three- phase AC input of AC sources is fed directly to bridge rectifiers, certain voltage level is required at the input terminal. When the voltage rating is 190-250Vac, it simply means that the voltage applied to each Bridge Rectifier must be 190 to 250 Vac . It doesn't matter if it’s fr ...
Diagnostic News On-Line Monitoring of Partial Discharge in Voltage Source January 2015
Diagnostic News On-Line Monitoring of Partial Discharge in Voltage Source January 2015

... the stress relief coatings which may lead to  overheating and high PD from degraded  coatings.  ...
interface ASD-NIB Analog Signal & Discrete Non-Incendive Barrier
interface ASD-NIB Analog Signal & Discrete Non-Incendive Barrier

... If a low impedance to 0V cannot be guaranteed on the return path, Wieland recommends the use of two barriers (one per signal) and to connect one of the return terminals on each barrier directly to ground ...
excitation systems
excitation systems

... and the manner in which they interface with each other  any given system may include only some or all of these functions depending on the specific application and the type of exciter  control functions regulate specific quantities at the desired level  limiting functions prevent certain quantitie ...
EE 101 Lab 5 PCB sub
EE 101 Lab 5 PCB sub

... The ECEbot circuitry requires a 5 volt DC supply. If we simply tried to use a combination of batteries to create the 5 volts, we would find that the actual voltage would vary as the load changed and as the batteries gradually discharged. This sort of voltage variation would lead to incorrect operati ...
LMD18200 3A, 55V H-Bridge 3A, 55V
LMD18200 3A, 55V H-Bridge 3A, 55V

stripfet iii and optimal choice of mosfets in high current vrms
stripfet iii and optimal choice of mosfets in high current vrms

... The right choice of the switches is fundamental to reach the maximum power efficiency. The switching and conduction losses due to the step-down conversion are both critical even if the weights are different for the upper and lower devices. In typical conditions the resulting duty factor is lower tha ...
Voltage Margining using the TPS62130
Voltage Margining using the TPS62130

Creating High Voltage Outputs
Creating High Voltage Outputs

- Connect Innovate UK
- Connect Innovate UK

... lay-out, DC power grids may be ungrounded, high-resistance grounded, or low-resistance grounded. In addition, the ground in such systems could be connected either to one of the poles or to the mid-rail point of the DC supply - in general, grounding arrangements used for AC power distribution grids c ...
AD8044
AD8044

... The capacitive load drive of the AD8044 can be increased by adding a low valued resistor in series with the load. Figure 35 shows the effects of a series resistor on capacitive drive for varying voltage gains. As the closed-loop gain is increased, the larger phase margin allows for larger capacitive ...
ENHANCEMENT OF TRANSIENT STABILITY FOR AN AC/DC
ENHANCEMENT OF TRANSIENT STABILITY FOR AN AC/DC

EEE
EEE

... 2. Students turn themselves into champions of their lives. 3. Students take things positively, convert everything into happiness and contribute for the happiness of others. 4. Students become potential sources for contributing to the development of the society around them and institutions / organisa ...
7_electric_1216
7_electric_1216

... and ground on the other. It’s usually not advisable to use this technique on components with more than two wires, especially if you’re relatively inexperienced in electrical troubleshooting. Some sensor circuits may be engineered to operate at a reduced voltage. This is usually a 5V reference, but m ...
CMOS Bandgap References (2)
CMOS Bandgap References (2)

On the design of a very high resolution DAC at 1 kHz for
On the design of a very high resolution DAC at 1 kHz for

8000 Series Fault Diagnosis Sheet Fault Diagnosis
8000 Series Fault Diagnosis Sheet Fault Diagnosis

... WHEN DID THE FAULT FIRST APPEAR? OTHER SYMPTOMS : ...
lecture5
lecture5

Maximizing Cell Monitoring Accuracy and Data Integrity in Energy
Maximizing Cell Monitoring Accuracy and Data Integrity in Energy

... uses a delta-sigma topology, aided by six userselectable filter options to address noisy environments. The delta-sigma approach reduces the effect of electromagnetic interference (EMI) and other transient noise, by its very nature of using many samples per conversion, with an averaging, filtering fu ...
NCP1612GEVB 160-W, Wide Mains, PFC Stage Driven by the NCP1612 Evaluation Board
NCP1612GEVB 160-W, Wide Mains, PFC Stage Driven by the NCP1612 Evaluation Board

... • At the first valley as classically done in CrM operation • Or at the first valley following the completion of the dead-time generated by the CCFF function to reduce the frequency. • The circuit nicely stays “locked” on to valley n until it needs to jump to either valley (n-1) or valley (n+1). In o ...
Application of reclosers in distribution systems requires
Application of reclosers in distribution systems requires

... Application of reclosers in distribution systems requires selection of its ratings such as minimum trip current, continuous current, symmetrical interrupting current etc. For a single phase system, single phase reclosers can be used whereas for a three phase system, one three phase recloser or three ...
Application of reclosers in distribution systems requires
Application of reclosers in distribution systems requires

A Control Strategy for Hybrid Power Filter to Compensate Four
A Control Strategy for Hybrid Power Filter to Compensate Four

Capacitor Self
Capacitor Self

MAX8857A Smallest, All-Internal MOSFET, 7-Channel 2 AA DSC PMIC General Description
MAX8857A Smallest, All-Internal MOSFET, 7-Channel 2 AA DSC PMIC General Description

... The MAX8857A PMIC provides a complete power-supply solution for digital still cameras (DSCs) and digital video cameras (DVCs). The MAX8857A improves performance, component count, and board space utilization compared to currently available solutions for 2 AA cell and dual-battery designs. On-chip pow ...
< 1 ... 806 807 808 809 810 811 812 813 814 ... 1265 >

Islanding

Islanding refers to the condition in which a distributed generator (DG) continues to power a location even though electrical grid power from the electric utility is no longer present. Islanding can be dangerous to utility workers, who may not realize that a circuit is still powered, and it may prevent automatic re-connection of devices. For that reason, distributed generators must detect islanding and immediately stop producing power; this is referred to as anti-islanding.The common example of islanding is a grid supply line that has solar panels attached to it. In the case of a blackout, the solar panels will continue to deliver power as long as irradiance is sufficient. In this case, the supply line becomes an ""island"" with power surrounded by a ""sea"" of unpowered lines. For this reason, solar inverters that are designed to supply power to the grid are generally required to have some sort of automatic anti-islanding circuitry in them.In intentional islanding, the generator disconnects from the grid, and forces the distributed generator to power the local circuit. This is often used as a power backup system for buildings that normally sell their excess power to the grid.