
MAX8677C 1.5A Dual-Input USB/AC Adapter Charger and Smart Power Selector General Description
... Smart Power Selector™ with dual (DC and USB) power inputs. It can operate with either separate inputs for USB and AC adapter power*, or from a single input that accepts both. All power switches for charging and switching the load between battery and external power are included on-chip. No external M ...
... Smart Power Selector™ with dual (DC and USB) power inputs. It can operate with either separate inputs for USB and AC adapter power*, or from a single input that accepts both. All power switches for charging and switching the load between battery and external power are included on-chip. No external M ...
equipotential planes, a figment
... be large enough to place the ammeter around a cow or other large object. Therefore, a voltmeter was substituted. With the proliferation of the dangerous multigrounded neutral electrical distribution system using the earth as a path for return neutral distribution current to flow back to the source s ...
... be large enough to place the ammeter around a cow or other large object. Therefore, a voltmeter was substituted. With the proliferation of the dangerous multigrounded neutral electrical distribution system using the earth as a path for return neutral distribution current to flow back to the source s ...
Fluke Corporation Fluke 83V Industrial Multimeter Manual
... verify the presence of hazardous voltages. Voltages greater than what is indicated may be present. First, make a voltage measurement without the filter to detect the possible presence of hazardous voltage. Then select the filter function. ...
... verify the presence of hazardous voltages. Voltages greater than what is indicated may be present. First, make a voltage measurement without the filter to detect the possible presence of hazardous voltage. Then select the filter function. ...
Senior Design I Final Document - UCF EECS
... also be designed and implemented that provides an efficient means of transferring the power generated into a stored and ready to use form available for consumer use. This includes a charging system capable of handling the simultaneous connection of 3 input devices, as well as the most efficient batt ...
... also be designed and implemented that provides an efficient means of transferring the power generated into a stored and ready to use form available for consumer use. This includes a charging system capable of handling the simultaneous connection of 3 input devices, as well as the most efficient batt ...
ZXMS6005DT8 Product Summary Features and Benefits
... 11. The drain current is restricted only when the device is in saturation (see graph ‘typical output characteristic’). This allows the device to be used in the fully on state without interference from the current limit. The device is fully protected at all drain currents, as the low power dissipatio ...
... 11. The drain current is restricted only when the device is in saturation (see graph ‘typical output characteristic’). This allows the device to be used in the fully on state without interference from the current limit. The device is fully protected at all drain currents, as the low power dissipatio ...
1.1. Modes of Operation
... of conversion and technology maintains two key objectives: the utility power is used as efficiently as possible, and the amount of distortion reflected back to the utility is minimized therefore providing cleaner power to other devices in the building not being protected by the N Series. PFC Control ...
... of conversion and technology maintains two key objectives: the utility power is used as efficiently as possible, and the amount of distortion reflected back to the utility is minimized therefore providing cleaner power to other devices in the building not being protected by the N Series. PFC Control ...
A MULTI-DIMENSIONAL SPREAD SPECTRUM TRANSCEIVER Saurabh Sinha Philosophiae Doctor (Electronic Engineering)
... utilize signal energy and bandwidth. In most communication systems these are essential issues. However, in some cases, there exist situations in which it is necessary for the system to resist external interference, to operate at low spectral energy, to provide multiple access capability without exte ...
... utilize signal energy and bandwidth. In most communication systems these are essential issues. However, in some cases, there exist situations in which it is necessary for the system to resist external interference, to operate at low spectral energy, to provide multiple access capability without exte ...
64-0007 Rev B - Magnum Dimensions
... To reduce the risk of electrical shock, fire, or other safety hazard, the following safety symbols have been placed throughout this manual to indicate dangerous and important safety instructions. WARNING: This symbol indicates that failure to take a specified action could result in physical harm to ...
... To reduce the risk of electrical shock, fire, or other safety hazard, the following safety symbols have been placed throughout this manual to indicate dangerous and important safety instructions. WARNING: This symbol indicates that failure to take a specified action could result in physical harm to ...
6.3 Power Strip Module - UCF EECS
... basic power monitoring system. Any device plugged into the power strip will have its power consumption and cost calculated and displayed on the touch screen. The feature will aid the homeowner on monthly power bill reduction and just overall reduction in wasted power consumption. When normal utility ...
... basic power monitoring system. Any device plugged into the power strip will have its power consumption and cost calculated and displayed on the touch screen. The feature will aid the homeowner on monthly power bill reduction and just overall reduction in wasted power consumption. When normal utility ...
INSTALLATION & OPERATING MANUAL X75 SERIES DC POWER POWER SYSTEM www.unipowerco.com
... shelf with a 2RU total height. This system holds up to six rectifier modules with up to 3900 watts output; it can be operated as a 5+1 redundant system with up to 3250 watts output. Each rectifier module is cooled by a fan that operates at a speed which is a function of load and temperature. There a ...
... shelf with a 2RU total height. This system holds up to six rectifier modules with up to 3900 watts output; it can be operated as a 5+1 redundant system with up to 3250 watts output. Each rectifier module is cooled by a fan that operates at a speed which is a function of load and temperature. There a ...
Improving the Stability of Cascaded DC/DC Converter Systems via
... load converter, simultaneously. In [25], one solution of this contradictory issue is presented by developing the regulation signal maps of the source converter into the regulation loop of the load converter. However, this method may be unachievable in some applications. For instance, if the source c ...
... load converter, simultaneously. In [25], one solution of this contradictory issue is presented by developing the regulation signal maps of the source converter into the regulation loop of the load converter. However, this method may be unachievable in some applications. For instance, if the source c ...
section 15172
... and digital output relays. CC. VFD shall provide plain language readouts of output frequency in hertz, PID feedback in percent, output voltage in volts, output current in amps, output power in kilowatts, DC bus voltage in volts, heatsink temperature in degrees, digital input terminal status, and fau ...
... and digital output relays. CC. VFD shall provide plain language readouts of output frequency in hertz, PID feedback in percent, output voltage in volts, output current in amps, output power in kilowatts, DC bus voltage in volts, heatsink temperature in degrees, digital input terminal status, and fau ...
LM120QML Series 3-Terminal Negative
... The LM120 needs only one external component—a compensation capacitor at the output, making them easy to apply. Worst case specifies on output voltage deviation due to any combination of line, load or temperature variation assure satisfactory system operation. Exceptional effort has been made to make ...
... The LM120 needs only one external component—a compensation capacitor at the output, making them easy to apply. Worst case specifies on output voltage deviation due to any combination of line, load or temperature variation assure satisfactory system operation. Exceptional effort has been made to make ...
EFFICIENT CONTROL OF THE SERIES RESONANT CONVERTER FOR HIGH FREQUENCY OPERATION
... limits of switching frequency are pushed. The goal of this thesis is to address two areas that practically limit the achievable switching frequency of resonant topologies. Traditional control methods based on single cycle response are impractical at high frequency; forcing the use of pulse density m ...
... limits of switching frequency are pushed. The goal of this thesis is to address two areas that practically limit the achievable switching frequency of resonant topologies. Traditional control methods based on single cycle response are impractical at high frequency; forcing the use of pulse density m ...
AD8342 数据手册DataSheet 下载
... Broadband RF, LO, and IF ports Conversion gain: 3.7 dB Noise figure: 12.2 dB Input IP3: 22.7 dBm Input P1dB: 8.3 dBm LO drive: 0 dBm Differential high impedance RF input port Single-ended, 50 Ω LO input port Open-collector IF output port Single-supply operation: 5 V @ 98 mA ...
... Broadband RF, LO, and IF ports Conversion gain: 3.7 dB Noise figure: 12.2 dB Input IP3: 22.7 dBm Input P1dB: 8.3 dBm LO drive: 0 dBm Differential high impedance RF input port Single-ended, 50 Ω LO input port Open-collector IF output port Single-supply operation: 5 V @ 98 mA ...
Riello UPS Dialog Dual DLD Series 5000-6000 Manual
... b) Avoid connecting the output neutral to the input neutral or to earth as this could cause malfunctions. c) DANGEROUS electrical voltages are generated inside the UPS. All installation and maintenance operations must be carried out EXCLUSIVELY by authorized personnel. d) The UPS contains an interna ...
... b) Avoid connecting the output neutral to the input neutral or to earth as this could cause malfunctions. c) DANGEROUS electrical voltages are generated inside the UPS. All installation and maintenance operations must be carried out EXCLUSIVELY by authorized personnel. d) The UPS contains an interna ...
VOS627A Optocoupler, Phototransistor Output, AC Input, Low Input
... Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vi ...
... Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vi ...
QUESTION BANK FOR SYB Sc. ELECTRONICS
... 16. When negative voltage feedback is applied to an amplifier of gain 1000 the overall gain falls to 6. Calculate the feedback factor. 17.When negative voltage feedback is applied to an amplifier of gain 60 the overall gain falls to 50. Calculate the feedback factor. 18 The gain and distortion of an ...
... 16. When negative voltage feedback is applied to an amplifier of gain 1000 the overall gain falls to 6. Calculate the feedback factor. 17.When negative voltage feedback is applied to an amplifier of gain 60 the overall gain falls to 50. Calculate the feedback factor. 18 The gain and distortion of an ...
ISSCC 2017
... technology is demonstrated. An efficient calibration technique, applied to a 27GHz-to-31GHz injection-locking frequency multiplier with quadrature outputs, is introduced. In the area of frequency synthesizers, three papers at ISSCC 2017 highlight advancements in digital architectures: a 50GHz-to-66G ...
... technology is demonstrated. An efficient calibration technique, applied to a 27GHz-to-31GHz injection-locking frequency multiplier with quadrature outputs, is introduced. In the area of frequency synthesizers, three papers at ISSCC 2017 highlight advancements in digital architectures: a 50GHz-to-66G ...
Report - KFUPM Faculty List
... caused by an over-current instance can cause electronic equipment to malfunction due to over-voltage, and disrupt service due to under-voltage. Poor discrimination between protection devices can cause upstream device operation, resulting in major interruption to service. The rapid advancement of bot ...
... caused by an over-current instance can cause electronic equipment to malfunction due to over-voltage, and disrupt service due to under-voltage. Poor discrimination between protection devices can cause upstream device operation, resulting in major interruption to service. The rapid advancement of bot ...