• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
AD8074/AD8075 500 MHz, G = +1 and +2 Triple
AD8074/AD8075 500 MHz, G = +1 and +2 Triple

... the output need swing only 2 V, then the buffers could be operated on dual 3.5 V or single 7 V supplies. It is cautioned that saturation effects may become noticeable when the output swings within 2.6 V of either rail. The system designer may opt to use this characteristic to his or her advantage by ...
7000A Thyristor Controlled Rectifier
7000A Thyristor Controlled Rectifier

... A Polaron Cortina 7,000 Amp rectifier offering a thryristor controllable 0-60 Volt output. Cortina specialise in the manufacture of Variable voltage and current thyristor rectifiers, for anodising, welding and plating applications. The Polaron Cortina is a primary SCR, single copper wound transforme ...
MIC5318 - Microchip
MIC5318 - Microchip

MAX2031EVKIT.pdf
MAX2031EVKIT.pdf

... This section provides a step-by-step guide to testing the basic functionality of the EV kit. As a general precaution to prevent damaging the outputs by driving high-VSWR loads, do not turn on DC power or RF signal generators until all connections are made. This procedure is specific to operation in ...
model 3800
model 3800

... 83 Ib. (Shipping) Specifications subject to change without notice. ...
Improvement of the Electric Power Quality Using Series Active and
Improvement of the Electric Power Quality Using Series Active and

LINEARITY ANALYSIS OF SPLIT SAR ADC
LINEARITY ANALYSIS OF SPLIT SAR ADC

... significantly. Successive approximation register (SAR) analog-to-digital converter is wellmatched with the standard CMOS process with low provides voltage, because it does not need ready amplifiers. A precious alternate is the split capacitive DAC, which has been lately reconsider for average resolu ...
127 A direct torque control of induction motor based on three
127 A direct torque control of induction motor based on three

... Fig.7 and Fig.9 show the simulation results of the conventional direct torque control (with two levels inverter and PI speed controller) applied to an induction machine for a reference speed variation and nominal load application. The real speed is obtained from the mechanical sensor. The obtained s ...
LW025 Single-Output-Series
LW025 Single-Output-Series

... operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included; however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a normal-blow fuse with a maximum rating of 5 ...
IOM Manual
IOM Manual

... The MotorGuard is a low-pass sine wave filter designed and developed by TCI to deliver conditioned power to motor loads driven by PWM drives at a variety of lead lengths. The MotorGuard is available for 460/480 volt and 575/600 volt systems. The MotorGuard is a passive filter connected in series wit ...
2LD545 User’s Manual For
2LD545 User’s Manual For

... A series motor configuration would typically be used in applications where a higher torque at lower speeds is required. Because this configuration has the most inductance, the performance will start to degrade at higher speeds. In series mode, the motors should also be run at only 70% of their rated ...
What is LDO (Low-Dropout Voltage Regulator) 2006/6  John Wu 吳旻翰
What is LDO (Low-Dropout Voltage Regulator) 2006/6 John Wu 吳旻翰

... (A) “Classic” NPN-based regulators that require 2.5 to 3V of excess input voltage to function.7805,317,340 (B) “Low Dropout NPN” regulators, with a NPN output but a PNP base drive circuit. These devices reduce the dropout requirement to 1.2 to 1.5V. (C) True low dropout PNP-based regulators that nee ...
FAN6754WA Highly Integrated Green-Mode PWM Controller FAN6754WA — Highly Integra
FAN6754WA Highly Integrated Green-Mode PWM Controller FAN6754WA — Highly Integra

... When the SENSE voltage across sense resistor RSENSE reaches the threshold voltage, around 0.46 V for lowline condition, the output GATE drive is turned off after a small delay, tPD. This delay introduces an additional current proportional to tPD • VIN / LP. Since the delay is nearly constant, regard ...
Abstract
Abstract

... 2.1 - Advantage of plasma speakers over conventional high-frequency speakers Conventional high frequency speakers have a number of drawbacks. One of the most difficult issues to address is the mass of the speaker. The voice coil, suspension system, and cone or dome of a conventional speaker all move ...
APC by Schneider Electric: Increasing Data Center Efficiency By
APC by Schneider Electric: Increasing Data Center Efficiency By

... racks is consumed by PDUs. In addition, the PDUs would make up more that 25% of the weight on the raised floor. Note that these impacts were much lower in data centers of the past which operated at approximately 2 kW per rack. Therefore, the benefit of using this new power distribution approach incr ...
AN1001 - PICList
AN1001 - PICList

... applied to the base of the NPN transistor. Normal leakage current is so low that the combined h FE of the specially coupled two-transistor feedback amplifier is less than unity, thus keeping the circuit in an off-state condition. A momentary positive pulse applied to the gate will bias the NPN trans ...
Isolation Transformers Increase Safety of Electronic Systems
Isolation Transformers Increase Safety of Electronic Systems

... Thermal design is simplified in the same way, since heat is distributed throughout the system, rather than concentrated in one location. Even though isolated DC-to-DC converters can be used to achieve high isolation in such a modular, distributed-power architecture, they are expensive compared to no ...
Utility Static Var Compensator (SVC)
Utility Static Var Compensator (SVC)

TA3404 Owner`s Manual Doc.indd
TA3404 Owner`s Manual Doc.indd

Triode Electronics Dynaco ST
Triode Electronics Dynaco ST

... After making any changes to R18, R21, R24, and R26 the bias of the EF86 must be adjusted manually by changing the cathode resistors (R14 and R17) and bleeder resistors (R19 and R25) to produce a plate voltage (pin 6 of EF86) between 80 and 115 volts. If the EF86 plate voltage is out of this range, t ...
Magnetic Performance of a Single Phase Induction Motor under
Magnetic Performance of a Single Phase Induction Motor under

Logic signal voltage levels
Logic signal voltage levels

Multi Look-Up Table Digital Predistortion for RF Power Amplifier Linearization Ph.D. Thesis
Multi Look-Up Table Digital Predistortion for RF Power Amplifier Linearization Ph.D. Thesis

... Considering a weak nonlinearity, the C/I3 can be calculated using the IP3 value [Sal05], which is usually provided by the manufacturer in the PA specifications: C/I3 [dBc] = IM D3ratio [dBc] = 2 (Pout [dBm] − OIP 3[dBm]) ...
Chapter 4 Re-VIEW
Chapter 4 Re-VIEW

... the cause of this problem, remove the case and check all connections from the power supply to the motherboard and drives (see Figure 4-26). Problems that Come and Go 1. Intermittent problems come and go. Review the symptoms that may indicate an intermittent problem with the electrical system after t ...
SIFT Scanner System
SIFT Scanner System

... microcontroller runs the scan based on input parameters. The step is set to 3 um, which means that the microcontroller will stop every 3 um and sample the OBIC signal and reflected laser signal simultaneously. The scan area is determined by simply setting the origin and navigating with the joystick ...
< 1 ... 591 592 593 594 595 596 597 598 599 ... 1265 >

Islanding

Islanding refers to the condition in which a distributed generator (DG) continues to power a location even though electrical grid power from the electric utility is no longer present. Islanding can be dangerous to utility workers, who may not realize that a circuit is still powered, and it may prevent automatic re-connection of devices. For that reason, distributed generators must detect islanding and immediately stop producing power; this is referred to as anti-islanding.The common example of islanding is a grid supply line that has solar panels attached to it. In the case of a blackout, the solar panels will continue to deliver power as long as irradiance is sufficient. In this case, the supply line becomes an ""island"" with power surrounded by a ""sea"" of unpowered lines. For this reason, solar inverters that are designed to supply power to the grid are generally required to have some sort of automatic anti-islanding circuitry in them.In intentional islanding, the generator disconnects from the grid, and forces the distributed generator to power the local circuit. This is often used as a power backup system for buildings that normally sell their excess power to the grid.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report