• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)

Cree XLamp LED Electrical Overstress Application Note
Cree XLamp LED Electrical Overstress Application Note

... Unlike many other LEDs on the market, most XLamp LEDs are capable of withstanding application of reverse voltage equal to the forward voltage of the device. In other words, if the LED load is connected with reverse polarity to a power supply with an output voltage less than or equal to the forward v ...
M5 Brochure - Societe Industrial Solutions Ltd
M5 Brochure - Societe Industrial Solutions Ltd

Schneider Electric White Template
Schneider Electric White Template

... limit capacitor inrush currents Air or Iron Core reactors in MV Anti-Resonant and Filtered systems detune the system to prevent resonance and remove up to 50% of the 5th harmonic ...
CrCM PFC Boost Converter Design - Digi-Key
CrCM PFC Boost Converter Design - Digi-Key

... mains voltage, in order to maximize the real power drawn from the mains. In a perfect PFC circuit, load should look like a pure resistance load. The input current is a clean sine wave and in phase with the voltage, with no input current harmonics. This document is intended to discuss the topology an ...
A New Wave of CMOS Power Amplifier Innovations: Fusing Digital
A New Wave of CMOS Power Amplifier Innovations: Fusing Digital

Universal Calibrator for Electrical Quantities for Power
Universal Calibrator for Electrical Quantities for Power

AND8093/D Current Sensing Power MOSFETs
AND8093/D Current Sensing Power MOSFETs

O A
O A

... Case (1) calibration the OCR without capacitor: The CT ratio is selected to provide some margin above the trip setting so meters will not read off - scale. The rated current of motor is195, it must multiply by 1.15 and 1.25 where 1.15 service factors and 1.25 relay pickup setting, then the rated cur ...
MAX8569A/MAX8569B 200mA Step-Up Converters in 6-Pin SOT23 and TDFN General Description
MAX8569A/MAX8569B 200mA Step-Up Converters in 6-Pin SOT23 and TDFN General Description

... SOT23 and TDFN The MAX8569A and MAX8569B compact high-efficiency step-up converters feature low-quiescent supply current to ensure the highest possible efficiency over a wide load range. With a minimum 1.5V input voltage, these devices are well suited for applications with two alkaline cells, two ni ...
Low-Dropout Regulator with modest ripple and rugged performance
Low-Dropout Regulator with modest ripple and rugged performance

... Transient response of LDO LDO provide power to low-voltage digital circuits operating under different modes of operation -voltage transients-cannot be handled by digital circuits Factors affecting transient response of an LDO  The internal compensation of the LDO  The amount of output capacitance ...
ADN8810 12-Bit High Output Current Source (Rev. A) Data Sheet
ADN8810 12-Bit High Output Current Source (Rev. A) Data Sheet

bus ele pp 10521 mv fuses quikship
bus ele pp 10521 mv fuses quikship

... Eaton and Bussmann® series current-limiting E-Rated, R-Rated and PT medium voltage fuses provide fusible circuit protection for motors, switchgear, transformers, small power and control transformers, and feeder circuits. Our portfolio includes a solution for virtually every medium voltage applicatio ...
AN-776 20 Watt Simple Switcher Forward Converter (Rev. A)
AN-776 20 Watt Simple Switcher Forward Converter (Rev. A)

... applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask ...
201: Voltage Measurement
201: Voltage Measurement

... tbey do not provide electrical isolation between tbe high voltage and tbe measuringsystemsand so impose special conditions for tbeir use. The cost of tbc electromagneticVT tends to increase at an exponential rate witb tbe rated voltage increase.An ...
Auto-Lite Type B Generator, Current Voltage Regulator
Auto-Lite Type B Generator, Current Voltage Regulator

BM400/2 Series Analogue/Digital Insulation Continuity Testers
BM400/2 Series Analogue/Digital Insulation Continuity Testers

... analogue scale. Due to the low test voltage and current of this range, it can be used to test circuits with sensitive equipment connected, without causing damage. Two voltage ranges measure up to 50,0 V and 600 V a.c. or d.c. respectively, and indicate the presence of negative d.c. A voltage warning ...
MAX1856 Wide Input Range, Synchronizable, PWM SLIC Power Supply General Description
MAX1856 Wide Input Range, Synchronizable, PWM SLIC Power Supply General Description

... input-to-output voltage ratio and the transformer’s turn ratio. The current-mode feedback loop regulates peak inductor current as a function of the output error signal. At light loads, the controller enters Idle Mode. During Idle Mode, switching pulses are provided only as necessary to supply the lo ...
Application of SVCs by CenterPoint Energy to Address Voltage
Application of SVCs by CenterPoint Energy to Address Voltage

... response. In many cases, one of the reasons for the disparity between simulated and actual response was incorrect load modeling. It has been proven that for voltage recovery studies the characteristics of motor response to voltages below about 80% of nominal must be taken into account to produce rea ...
Common Mode Rejection Ratio
Common Mode Rejection Ratio

ACTIVE POWER FILTERING TECHNIQUES FOR HARMONIC
ACTIVE POWER FILTERING TECHNIQUES FOR HARMONIC

... The increasing use of power electronics-based loads (adjustable speed drives, switch mode power supplies, etc.) to improve system efficiency and controllability is increasing the concern for harmonic distortion levels in end use facilities and on the overall power system. The application of passive ...
Simplify Multiple Bias Voltage Sequencing and
Simplify Multiple Bias Voltage Sequencing and

... mainframe digital I/O port provided a convenient means of generating the PW-OK output signal without any extra equipment. An extra slot is available in each of the mainframes for adding another module. This could be used as another output or paralleled with an existing output for greater power, if d ...
VS Series Installation & Application Notes 500 - 2500 Watts
VS Series Installation & Application Notes 500 - 2500 Watts

... Dynamic response ...
Siemens Simatic ST70 Control Systems 2011
Siemens Simatic ST70 Control Systems 2011

... Signal voltage for connection to T400 (HTL, unipolar) • for "0" signal • for "1" signal ...
Evaluates: MAX848/MAX849 MAX849 Evaluation Kit _______________General Description ____________________________Features
Evaluates: MAX848/MAX849 MAX849 Evaluation Kit _______________General Description ____________________________Features

... kit, and how to evaluate its performance. Do not turn on the power supply until all connections are completed. 1) Configure the jumper and resistor settings as desired. For a standard 3.3V output and 90% power-OK threshold, close jumper JU1 (Table 1). 2) Insert an AA-size battery cell into the batte ...
< 1 ... 566 567 568 569 570 571 572 573 574 ... 1265 >

Islanding

Islanding refers to the condition in which a distributed generator (DG) continues to power a location even though electrical grid power from the electric utility is no longer present. Islanding can be dangerous to utility workers, who may not realize that a circuit is still powered, and it may prevent automatic re-connection of devices. For that reason, distributed generators must detect islanding and immediately stop producing power; this is referred to as anti-islanding.The common example of islanding is a grid supply line that has solar panels attached to it. In the case of a blackout, the solar panels will continue to deliver power as long as irradiance is sufficient. In this case, the supply line becomes an ""island"" with power surrounded by a ""sea"" of unpowered lines. For this reason, solar inverters that are designed to supply power to the grid are generally required to have some sort of automatic anti-islanding circuitry in them.In intentional islanding, the generator disconnects from the grid, and forces the distributed generator to power the local circuit. This is often used as a power backup system for buildings that normally sell their excess power to the grid.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report