• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Phase Leg IGBT with an Integrated Driver Module
Phase Leg IGBT with an Integrated Driver Module

DC SIGNAL SOURCE SS7012
DC SIGNAL SOURCE SS7012

Alberta Reliability Standard Generator Operation for Maintaining Network Voltages VAR-002-AB-1.1b
Alberta Reliability Standard Generator Operation for Maintaining Network Voltages VAR-002-AB-1.1b

... R2 The operator of an aggregated generating facility, subject to requirement R3 and the ISO’s consent to operate otherwise, must only operate such aggregated generating facility with the voltage regulating system in service, in voltage control mode and controlling voltage. R3 Each operator of a gene ...
MULTIPLE CHOICE QUESTIONS (MCQS) Chapter 2: Thyristor
MULTIPLE CHOICE QUESTIONS (MCQS) Chapter 2: Thyristor

Module B3 Three Phase Analysis
Module B3 Three Phase Analysis

D6 Amplifier Hardware manual (1.9 EN)
D6 Amplifier Hardware manual (1.9 EN)

... The switch mode mains power supply permits worldwide application without the need for mains voltage switching or conversion. The power supply incorporates active Power Factor Correction (PFC) which provides a clean and highly efficient sinusoidal current draw, thus providing highest performance unde ...
BD6382EFV
BD6382EFV

... This IC has a built in over current protection circuit as a provision against destruction when the motor outputs are shorted each other or VCC-output or motor output-GND is shorted. This circuit latches the motor output to OPEN condition when the regulated threshold current flows for 4μs (typ.). It ...
2. digital instruments - ELECTRONICS AND INSTRUMENTATION
2. digital instruments - ELECTRONICS AND INSTRUMENTATION

NJU7380
NJU7380

PSU_Part1_EfficiencyPowerFactor - Renesas e
PSU_Part1_EfficiencyPowerFactor - Renesas e

...  Transformer changes AC voltage (eg. AC 100 V -> AC 12 V), and electrically isolates the secondary side from the primary ...
Battery charge I.C. - STMicroelectronics
Battery charge I.C. - STMicroelectronics

... the accessories with a strong current. The drop of the internal P-Channel MOS is very low (200mV @ 800mA) and the switch properly work for VBATT higher than 2.5V. This allows to supply energy on the VCHARGE pin. When the switch is ON (CMD-REVERSE high) the current direction into the chip is from VBA ...
Multilevel converters
Multilevel converters

... Each level of the full-bridge converter consists of four switches, SI, S,, S,, and S,. Using the top level as the example, turning on SI and S, yields vI=+Vdc. Turing on S, and S, yields v]=-vdc. Turning off a11 switches yieIds vI=O. Similarly, the ac output voltage at each level can be obtained in ...
TPS54872 数据资料 dataSheet 下载
TPS54872 数据资料 dataSheet 下载

... signals. Noise injected between the two grounds can degrade the performance of the TPS54872, particularly at higher output currents. Ground noise on an analog ground plane can also cause problems with some of the control and bias signals. For these reasons, separate analog and power ground traces ar ...
Alberta Reliability Standard Generator Operation for Maintaining Network Voltages VAR-002-AB-1.1b
Alberta Reliability Standard Generator Operation for Maintaining Network Voltages VAR-002-AB-1.1b

... R2 The operator of an aggregated generating facility, subject to requirement R3 and the ISO’s consent to operate otherwise, must only operate such aggregated generating facility with the voltage regulating system in service, in voltage control mode and controlling voltage. R3 Each operator of a gene ...
DATA  SHEET BGY135; BGY136 VHF power amplifier modules 1996 May 08
DATA SHEET BGY135; BGY136 VHF power amplifier modules 1996 May 08

... more of the limiting values may cause permanent damage to the device. These are stress ratings only and operation of the device at these or at any other conditions above those given in the Characteristics sections of the specification is not implied. Exposure to limiting values for extended periods ...
A Study of CMOS Current Comparators in 180 nm Technology
A Study of CMOS Current Comparators in 180 nm Technology

IOSR Journal of Electronics and Communication Engineering (IOSR-JECE)
IOSR Journal of Electronics and Communication Engineering (IOSR-JECE)

... for impedance matching between these two networks. Biasing techniques may be used along with the supply network for the driver stage and the power stage. For biasing current mirror circuits may be used. ...
DU-40ACI1 & DU-40ACI5 1 Amp and 5 Amp AC Meters
DU-40ACI1 & DU-40ACI5 1 Amp and 5 Amp AC Meters

... DU-35ACI1/5 ..........AC amps, Scaled RMS. (1 or 5 Amp Internal shunt), 3.5 digit DU-35ACIRMS1/5 ..AC amps, True RMS. (1 or 5 Amp Internal shunt), 3.5 digit DU-40ACI1-5 ..........AC amps, Scaled RMS. (1 or 5 Amp Internal shunt), 4 digit DU-35AC ........................AC volts, Scaled RMS. 199.9/700 ...
passive techniques for reducing input current
passive techniques for reducing input current

Improved, Quad, SPST Analog Switches General Description New Features
Improved, Quad, SPST Analog Switches General Description New Features

... Note 2: Typical values are for design aid only, are not guaranteed, and are not subject to production testing. The algebraic convention, where the most negative value is a minimum and the most positive value a maximum, is used in this data sheet. Note 3: Guaranteed by design. Note 4: On-resistance m ...
RF3021 SPDT, HIGH ISOLATION, SINGLE BIT CONTROL, REFLECTIVE SWITCH Features
RF3021 SPDT, HIGH ISOLATION, SINGLE BIT CONTROL, REFLECTIVE SWITCH Features

... Exceeding any one or a combination of the Absolute Maximum Rating conditions may cause permanent damage to the device. Extended application of Absolute Maximum Rating conditions to the device may reduce device reliability. Specified typical performance or functional operation of the device under Abs ...
35 W wide-range high power factor flyback converter evaluation
35 W wide-range high power factor flyback converter evaluation

... EVL6562A-35WFLB evaluation board using the L6562A . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 EVL6562A-35WFLB evaluation board: electrical schematic . . . . . . . . . . . . . . . . . . . . . . . . 6 EVL6562A-35WFLB compliance with EN61000-3-2 Class-C limits @ full load . . . . . . . . . ...
High-Speed Digital Output PLC Module
High-Speed Digital Output PLC Module

... Assuming load capacitance is around 5 nF including cable and receiver capacitance. If 1-MHz speed is to be achieved and RC time constant of the load is to be kept below 0.1 in a period of 1 μs, a maximum load of 20 Ω must be used. When full-swing driving is used (like CMOS or TTL) and to maintain th ...
PP101007-a - Indico
PP101007-a - Indico

... A Command is defined as something that is recognized by the Power Supply and drives the Power Supply between two states. The Commands for the Power Supply are: OFF: If no DEFECT is present, the power supply is transitioned to the OFF state. In this state the outputs of the AC power sections of the s ...
AIremote Battery Monitor Users Guide
AIremote Battery Monitor Users Guide

... This is the application note for the Battery Monitoring Algorithm, designed to operate on the AIremote. The algorithm was developed using the Telcordia Battery Specification, specifically using the Coup de Fouet, which is the name given to the transient response of a cell (or battery) when it is tak ...
< 1 ... 542 543 544 545 546 547 548 549 550 ... 1265 >

Islanding

Islanding refers to the condition in which a distributed generator (DG) continues to power a location even though electrical grid power from the electric utility is no longer present. Islanding can be dangerous to utility workers, who may not realize that a circuit is still powered, and it may prevent automatic re-connection of devices. For that reason, distributed generators must detect islanding and immediately stop producing power; this is referred to as anti-islanding.The common example of islanding is a grid supply line that has solar panels attached to it. In the case of a blackout, the solar panels will continue to deliver power as long as irradiance is sufficient. In this case, the supply line becomes an ""island"" with power surrounded by a ""sea"" of unpowered lines. For this reason, solar inverters that are designed to supply power to the grid are generally required to have some sort of automatic anti-islanding circuitry in them.In intentional islanding, the generator disconnects from the grid, and forces the distributed generator to power the local circuit. This is often used as a power backup system for buildings that normally sell their excess power to the grid.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report