Optimized Distribution Feeder Protection With Remote and Local
... electromechanical relay components could, in theory, go undiscovered for long periods of time and fail to operate when needed. The latest generation of numerical feeder protection relays addresses reliability and testing concerns while providing extensive functionality at relatively low installation ...
... electromechanical relay components could, in theory, go undiscovered for long periods of time and fail to operate when needed. The latest generation of numerical feeder protection relays addresses reliability and testing concerns while providing extensive functionality at relatively low installation ...
2350 POWER SERIES Selector Guide
... Input terminals to case: 2300 Volts AC for 1 minute (except 2351 is 1500 V AC) ...
... Input terminals to case: 2300 Volts AC for 1 minute (except 2351 is 1500 V AC) ...
Glossary - General for Electron and Ion Guns
... Analog meter: A meter with a dial and pointer which displays current or voltage. Anode: (also G-2) (1) The second electrostatic lens element in the gun, which usually provides the potential difference that accelerates the electrons; the third element of the triode; usually a tube with an ...
... Analog meter: A meter with a dial and pointer which displays current or voltage. Anode: (also G-2) (1) The second electrostatic lens element in the gun, which usually provides the potential difference that accelerates the electrons; the third element of the triode; usually a tube with an ...
PI3HDMI412AD_HDMI_ApplicationInformation
... One low-ESR 0.1uF decoupling capacitor should be mounted at each VDD pin. Smaller body size capacitors can facilitate component placement. The capacitor should be placed next to a VDD pin, i.e. within 100mil. One capacitor with capacitance in the range of 4.7uF to 10uF should be incorporated in ...
... One low-ESR 0.1uF decoupling capacitor should be mounted at each VDD pin. Smaller body size capacitors can facilitate component placement. The capacitor should be placed next to a VDD pin, i.e. within 100mil. One capacitor with capacitance in the range of 4.7uF to 10uF should be incorporated in ...
MAX2370 Complete 450MHz Quadrature Transmitter General Description Features
... Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Expo ...
... Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Expo ...
STABILITY ANALYSIS AND OPTIMAL CONTROL DESIGN FOR AC-DC POWER SYSTEM WITH by
... Power electronics are involved in many applications. The number of applications has been growing significantly during the last decades. Among those applications, there is a typical type of load: the constant power load (CPL). This type of load has always been an important issue both for the industry ...
... Power electronics are involved in many applications. The number of applications has been growing significantly during the last decades. Among those applications, there is a typical type of load: the constant power load (CPL). This type of load has always been an important issue both for the industry ...
Hydro Generator Simulator - wsu-eecs
... model, and thus no quadrature axis saturation is present for Figure 3. As a result, the equations for the flux linkages of the salient-pole machine are more difficult to use than their round-rotor counterparts [4]. Fortunately, the equations that pertain to the a, b, and c phases can be transformed ...
... model, and thus no quadrature axis saturation is present for Figure 3. As a result, the equations for the flux linkages of the salient-pole machine are more difficult to use than their round-rotor counterparts [4]. Fortunately, the equations that pertain to the a, b, and c phases can be transformed ...
A 1.2- mu m CMOS current-controlled oscillator - Solid
... capacitor CT. Although the unavoidable stray capacitances Cpl and Cpr do not form part of the timing capacitance, they nevertheless have an effect on oscillator timing. In order to overcome this problem, Sneep and Verhoven [12] and Banu [IO] (in a MOS equivalent) replaced the single floating capacit ...
... capacitor CT. Although the unavoidable stray capacitances Cpl and Cpr do not form part of the timing capacitance, they nevertheless have an effect on oscillator timing. In order to overcome this problem, Sneep and Verhoven [12] and Banu [IO] (in a MOS equivalent) replaced the single floating capacit ...
DC1646A LTC5564 15GHz RF Power Detector with Comparator
... or Table 3 for the typical VOUTADJ voltage for the desired VOUT DC output offset in each gain setting. The VCC_OUT (E12) test point is an alternative output of VOUT (J3 SMA CONNECTOR). Install a 0Ω resistor or a jumper at R5 will have the VOUT at this VCC_OUT test point. The R7 and C12 footprints ar ...
... or Table 3 for the typical VOUTADJ voltage for the desired VOUT DC output offset in each gain setting. The VCC_OUT (E12) test point is an alternative output of VOUT (J3 SMA CONNECTOR). Install a 0Ω resistor or a jumper at R5 will have the VOUT at this VCC_OUT test point. The R7 and C12 footprints ar ...
LTC6900 - Low Power, 1kHz to 20MHz Resistor
... spanning 0.1MHz to 20MHz. However, accuracy may suffer if the master oscillator is operated at greater than 10MHz with a supply voltage lower than 4V. A programmable divider extends the frequency range to greater than three decades. Table 1 describes the recommended frequencies for each divider sett ...
... spanning 0.1MHz to 20MHz. However, accuracy may suffer if the master oscillator is operated at greater than 10MHz with a supply voltage lower than 4V. A programmable divider extends the frequency range to greater than three decades. Table 1 describes the recommended frequencies for each divider sett ...
Guidelines for Grid-connected Small Scale (Rooftop) Solar PV
... In Tamil Nadu a facility known as “net-metering” has been introduced. In netmetering the solar energy exported to the grid is deducted from the energy imported from the grid subject to certain conditions. The consumer pays for the net-energy imported from the grid. To enable net-metering TANGEDCO wi ...
... In Tamil Nadu a facility known as “net-metering” has been introduced. In netmetering the solar energy exported to the grid is deducted from the energy imported from the grid subject to certain conditions. The consumer pays for the net-energy imported from the grid. To enable net-metering TANGEDCO wi ...
Application Note - Aeroflex Microelectronic Solutions
... In spacecraft applications, the temperature sensors are often located at some distance from the data acquisition unit, which contains the MUX, excitation source and processor, and are connected by cables. As a result, designing to meet EMI requirements is critical, particularly with respect to Radia ...
... In spacecraft applications, the temperature sensors are often located at some distance from the data acquisition unit, which contains the MUX, excitation source and processor, and are connected by cables. As a result, designing to meet EMI requirements is critical, particularly with respect to Radia ...
i.MX35 Multimedia Power Consumption Under Linux
... layout of the CPU card precluded separating the i.MX35 from the other devices on that power supply rail, the relative proportion of contribution to power is assumed to be constant. The second two columns are difference between the power consumption calculated for each codec and the idle current when ...
... layout of the CPU card precluded separating the i.MX35 from the other devices on that power supply rail, the relative proportion of contribution to power is assumed to be constant. The second two columns are difference between the power consumption calculated for each codec and the idle current when ...
Aalborg Universitet Control and Virtual Impedance
... two types. One is PQ bus and the other is the bus where the DG unit with droop control and virtual impedance is connected (here it is called dispatchable DG bus). The PQ buses include not only load but also nodes connected with an non-dispatchable DG unit. Generally, the dispatchable DGs are diesel ...
... two types. One is PQ bus and the other is the bus where the DG unit with droop control and virtual impedance is connected (here it is called dispatchable DG bus). The PQ buses include not only load but also nodes connected with an non-dispatchable DG unit. Generally, the dispatchable DGs are diesel ...
LM5015 High Voltage Monolithic Two-Switch Forward DC
... The LM5015 provides two separate input power pins, VIN and PVIN, allowing for flexible decoupling options. The VIN pin provides power to the low drop-out VCC bias regulator which powers all internal control blocks. The PVIN connects directly to the high side MOSFET drain. If used with a single input ...
... The LM5015 provides two separate input power pins, VIN and PVIN, allowing for flexible decoupling options. The VIN pin provides power to the low drop-out VCC bias regulator which powers all internal control blocks. The PVIN connects directly to the high side MOSFET drain. If used with a single input ...
Analog-to-Digital Conversion Utilizing AT89LP
... In this application (Figure 5), an AT89CX051 microcontroller with an integral analog comparator performs the SAR function in software, reducing the component count. The DAC selected for the application is an MC1408-8, eight-bit, current output type chosen for its low cost. Seven- and six-bit versio ...
... In this application (Figure 5), an AT89CX051 microcontroller with an integral analog comparator performs the SAR function in software, reducing the component count. The DAC selected for the application is an MC1408-8, eight-bit, current output type chosen for its low cost. Seven- and six-bit versio ...
EE 442 Lab Experiment No. 2 Introduction to the Measurement of
... meter can be used with little difference in operation. Voltmeter A voltmeter measures electrical potential between its terminals. Voltmeters are always placed in parallel with the circuit or circuit element where the voltage measurement is desired. Since the voltage across two or more parallel eleme ...
... meter can be used with little difference in operation. Voltmeter A voltmeter measures electrical potential between its terminals. Voltmeters are always placed in parallel with the circuit or circuit element where the voltage measurement is desired. Since the voltage across two or more parallel eleme ...