• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
12 - Research Script International Journals
12 - Research Script International Journals

... the boost inductor in energy storing mode or goes to the load in energy transferring mode. But, in an isolated boost converter, commutation from energy storing mode to energy transferring mode cannot take place instantly due to the existence of the leakage inductance of the isolation transformer. Th ...
ec 6404 linear integrated circuits ltpc
ec 6404 linear integrated circuits ltpc

... IC741 has a low slew rate because of the predominance of capacitance present in the circuit at higher frequencies. As frequency increases the output gets distorted due to limited slew rate. 21. What causes slew rate. (MAY 2008) There is a capacitor with-in or outside of an op-amp to prevent oscillat ...
Power Factor Controller „BR 5306 / 5312“ Instruction book
Power Factor Controller „BR 5306 / 5312“ Instruction book

... If the "- C" LED is alight in spite of an inductive mains load when the BR 53 is put into operation, this points to the fact that the measuring voltage or measuring current terminals may have been mixed up, with target p.f. set to 1, or that the phase position was not considered. This also applies i ...
Alarm Unit Hooter / Siren / Buzzer / Bell
Alarm Unit Hooter / Siren / Buzzer / Bell

PS9332L, PS9332L2 Data Sheet
PS9332L, PS9332L2 Data Sheet

... output side might affect the photocoupler’s LED input, leading to malfunction or degradation of characteristics. (If the pattern needs to be close to the input block, to prevent the LED from lighting during the off state due to the abovementioned coupling, design the input-side circuit so that the b ...
adom smart i/o - Smart Controls, LLC
adom smart i/o - Smart Controls, LLC

... indicator will be illuminated providing the user with confirmation the particular analog channel has been placed in the manual mode of operation. Each analog channel has its own manual override indicator LED. The ADOM can be powered with either AC or DC voltages. A green LED indicator is illuminated ...
Low Power Techniques
Low Power Techniques

...  (1) The generalized spring which may undergo deformation caused by a driving force from the driver;  (2) The switch which determines a logic transition in response to the driving force, depending on the input information;  (3) The communication channel through which state information can be conv ...
O A RIGINAL RTICLE
O A RIGINAL RTICLE

... voltage waveform and any deviation from these predesigned magnitude and frequency can cause power quality problems and resultantly failure of equipment on the customer side (Dugan et al. 2003). Among the power quality disturbances, voltage sag and harmonic distortion are the most important disturban ...
pdf format
pdf format

... In this mode, an analog 0–10 VDC signal applied to the ANV/C input connector remotely controls laser power. PWM duty cycle output is approximately proportional to voltage applied. The front panel Power Adj knob is disabled when the Mode switch is set to ANV. Remote Current Control (ANC) In this mode ...
ENHANCING FUEL BURNING EFFICIENCY BY REGULATE SPARK
ENHANCING FUEL BURNING EFFICIENCY BY REGULATE SPARK

... where it is high performances, low emission and less fuel consumption. Piezoelectric actuators require a high DCbus voltage to obtain high performance. The FPGA controlled coupled inductor boost is presented as a good option to solve high boosting requirements in automotive applications. High power ...
Stray Voltage: Sources and Solutions
Stray Voltage: Sources and Solutions

A Novel Piezoelectric Microtransformer for Autonmous Sensors Applications  Senior Member, IEEE
A Novel Piezoelectric Microtransformer for Autonmous Sensors Applications Senior Member, IEEE

... any power supply and allows sufficient amplification to generate up to 5.4 V DC starting from a voltage of only 50 mV AC (available at the output of the micro transformer). Also, the with power consumption is very low : 60 nW in the transient (of 2 ms) and 2.97 pW in the steady state, with the corre ...
FEATURES DESCRIPTION D
FEATURES DESCRIPTION D

... complete device failure. Precision integrated circuits may be more susceptible to damage because very small parametric changes could cause the device not to meet its published specifications. ...
Aalborg Universitet permanently connected shunt reactor
Aalborg Universitet permanently connected shunt reactor

Comparative Analysis of 150W RF VDMOS Transistors
Comparative Analysis of 150W RF VDMOS Transistors

... elevated device junction temperature due to increased dissipation from reflected power. Although ruggedness and survivability are general, albeit vague terms, it is well understood that the device ruggedness can be improved by enhancing its thermal performance as well as lowering the operating outpu ...
STP 3 & 4 8.3  Onsite Power Systems
STP 3 & 4 8.3 Onsite Power Systems

... utilizes digital timers that can reproduce the timing requirements by sensing the number of cycles of the electrical waveform itself. Coordination of the definite time delay and the upstream bus feeder breakers allows termination of the fault current before the feeder breakers are free to trip. Trip ...
Photodiode Technical Information
Photodiode Technical Information

... When light strikes a photodiode, the electron within the crystal structure becomes stimulated. If the light energy is greater than the band gap energy Eg, the electrons are pulled up into the conduction band, leaving holes in their place in the valence band. (See Figure 1-2) These electron-hole pair ...
When power interruptions happen.
When power interruptions happen.

... Bad order equipment: Equipment that mis-operated or caused an interruption resulting from equipment being damaged or deteriorated. Breaker lockout (lockout): The operation that occurs when a circuit breaker is unable to clear a fault. When a breaker locks out, it typically results in a sustained int ...
Hi-Rel DC/DC CONVERTER MGDM-200 : 200W
Hi-Rel DC/DC CONVERTER MGDM-200 : 200W

... The synchronization function allows to synchronize one converter to the other or to an external frequency source. The load sharing allows parallel operation to increase output power with a true N+1 without any additionnal external components. ...
II. Principle of HVDC Transmission System
II. Principle of HVDC Transmission System

AL8807Q Description Pin Assignments
AL8807Q Description Pin Assignments

... LED current can be adjusted digitally, by applying a low frequency Pulse Width Modulated (PWM) logic signal to the CTRL pin to turn the device on and off. This will produce an average output current proportional to the duty cycle of the control signal. In particular, a PWM signal with a max resoluti ...
ancillary service details: voltage control
ancillary service details: voltage control

... to continue operating without impacting any customers. That is, the system is designed to withstand a single contingency. Taken together, these two factors result in a dynamic reactive-power requirement. The loss of a generator or a major transmission line can have the compounding effect of reducing ...
Rail-to-Rail I/O, 2A Power Amplifier (Rev. A)
Rail-to-Rail I/O, 2A Power Amplifier (Rev. A)

... Input signals that can swing more than 0.5V beyond the supply rails should be current limited to 10mA or less. (3) Short-circuit to ground. ...
Radiometers
Radiometers

STP 3 & 4 8.3  Onsite Power Systems
STP 3 & 4 8.3 Onsite Power Systems

... diesel bus source. Switching back to the Class 1E diesel bus power is by manual action only. Per IEEE-384 and Regulatory Guide 1.75, isolation between the Class 1E bus and non-1E load is maintained. STD DEP 8.3-1 STP DEP 8.3-3 The design minimizes the probability of a single failure affecting more t ...
< 1 ... 383 384 385 386 387 388 389 390 391 ... 1265 >

Islanding

Islanding refers to the condition in which a distributed generator (DG) continues to power a location even though electrical grid power from the electric utility is no longer present. Islanding can be dangerous to utility workers, who may not realize that a circuit is still powered, and it may prevent automatic re-connection of devices. For that reason, distributed generators must detect islanding and immediately stop producing power; this is referred to as anti-islanding.The common example of islanding is a grid supply line that has solar panels attached to it. In the case of a blackout, the solar panels will continue to deliver power as long as irradiance is sufficient. In this case, the supply line becomes an ""island"" with power surrounded by a ""sea"" of unpowered lines. For this reason, solar inverters that are designed to supply power to the grid are generally required to have some sort of automatic anti-islanding circuitry in them.In intentional islanding, the generator disconnects from the grid, and forces the distributed generator to power the local circuit. This is often used as a power backup system for buildings that normally sell their excess power to the grid.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report