![MAX14508E–MAX14511E/MAX14509AE USB 2.0 Hi-Speed and Audio Switches with Negative Signal Capability General Description](http://s1.studyres.com/store/data/008860200_1-4f6acc3fe96cf16681f499b5675c5d80-300x300.png)
MAX14508E–MAX14511E/MAX14509AE USB 2.0 Hi-Speed and Audio Switches with Negative Signal Capability General Description
... video. These devices combine the low on-capacitance (CON) and low on-resistance (RON) necessary for highperformance switching applications in portable electronics, and include an internal negative supply to pass audio signals that swing below ground (down to VCC 5.0V). The MAX14508E–MAX14511E/MAX145 ...
... video. These devices combine the low on-capacitance (CON) and low on-resistance (RON) necessary for highperformance switching applications in portable electronics, and include an internal negative supply to pass audio signals that swing below ground (down to VCC 5.0V). The MAX14508E–MAX14511E/MAX145 ...
Switch Mode Power Supply (15/25/35/50/75/100/150/200/350
... • Global Standards: Conforms to CE (all models), Approved for UL (all models) and CCC (15 to 150-W models). • Easy mounting to DIN Rails with Mounting Brackets. * Refer to Period and Terms of Warranty on page 39. Refer to Safety Precautions for All Power Supplies and Safety Precautions on page 36. ...
... • Global Standards: Conforms to CE (all models), Approved for UL (all models) and CCC (15 to 150-W models). • Easy mounting to DIN Rails with Mounting Brackets. * Refer to Period and Terms of Warranty on page 39. Refer to Safety Precautions for All Power Supplies and Safety Precautions on page 36. ...
WBK Options User`s Manual
... WBK12A and WBK13A are 8-channel programmable low-pass filter cards for use with WaveBook data acquisition systems. These cards install directly into a WaveBook or WBK10A module and provide programmable low-pass filtering over all channels. Multiple WBK12A and WBK13A cards can be installed in one sys ...
... WBK12A and WBK13A are 8-channel programmable low-pass filter cards for use with WaveBook data acquisition systems. These cards install directly into a WaveBook or WBK10A module and provide programmable low-pass filtering over all channels. Multiple WBK12A and WBK13A cards can be installed in one sys ...
Technical guide Protection criteria for medium voltage
... and additional protections can also be provided exploiting the potential logics and protection functions available in digital relays. The “from the theoretical point of view” statement, is to underline that, from the theoretical point of view, it is possible to identify and therefore eliminate just ...
... and additional protections can also be provided exploiting the potential logics and protection functions available in digital relays. The “from the theoretical point of view” statement, is to underline that, from the theoretical point of view, it is possible to identify and therefore eliminate just ...
Liebert NXL UPS 1100kVA 1+N Multi-Module
... redundant or non-redundant as stated elsewhere in this specification. In a non-redundant system, all the modules making up the UPS system shall supply the full rated load. If a module should malfunction, placing an overload on the remaining on-line modules, the load shall be transferred automaticall ...
... redundant or non-redundant as stated elsewhere in this specification. In a non-redundant system, all the modules making up the UPS system shall supply the full rated load. If a module should malfunction, placing an overload on the remaining on-line modules, the load shall be transferred automaticall ...
D-500 - datakom electronics engineering as
... When the unit is connected to the network do not touch terminals. Short circuit terminals of unused current transformers. Any electrical parameter applied to the device must be in the range specified in the user manual. Although the unit is designed with a wide safety margin, over-range parame ...
... When the unit is connected to the network do not touch terminals. Short circuit terminals of unused current transformers. Any electrical parameter applied to the device must be in the range specified in the user manual. Although the unit is designed with a wide safety margin, over-range parame ...
Submersible Motors - Stallion Equipment
... When the pump-motor operates in water hotter than 30°C, a flow rate of at least .91 m/sec is required. When selecting the motor to drive a pump in over 30°C water, the motor horsepower must be de-rated per the ...
... When the pump-motor operates in water hotter than 30°C, a flow rate of at least .91 m/sec is required. When selecting the motor to drive a pump in over 30°C water, the motor horsepower must be de-rated per the ...
Handbook on Electricity Meters
... Measurement accuracy will not necessarily result in equity if the accurate measurements are used in an inappropriate or inconsistent manner. ...
... Measurement accuracy will not necessarily result in equity if the accurate measurements are used in an inappropriate or inconsistent manner. ...
Service Manual
... SG SPARE PARTS LIST - 230V (7.5 - 40 HP) Description CONTROL PCB assembly POWER PCB assembly SMPS (CTRL) PCB assembly SMPS (DRV) PCB assembly DM+CT PCB assembly SNUBBER PCB assembly ...
... SG SPARE PARTS LIST - 230V (7.5 - 40 HP) Description CONTROL PCB assembly POWER PCB assembly SMPS (CTRL) PCB assembly SMPS (DRV) PCB assembly DM+CT PCB assembly SNUBBER PCB assembly ...
MAX11131 Evaluation Kit Evaluates: MAX11131 General Description
... 2) Install the EV kit software on your computer by running the INSTALL.EXE program inside the temporary folder. The program files are copied to your PC and icons are created in the Windows Start | Programs menu. During software installation, some versions of Windows may show a warning message indic ...
... 2) Install the EV kit software on your computer by running the INSTALL.EXE program inside the temporary folder. The program files are copied to your PC and icons are created in the Windows Start | Programs menu. During software installation, some versions of Windows may show a warning message indic ...
Solid State Guitar Amplifiers - Teemu
... A heartfelt thanks goes out to Nigel Goodwin, Don Booth and Joseph Raymond who assisted in proofreading this book. They should not however be held responsible for any errors or oversights. Another heartfelt thanks goes out to Hugh Dean, whose contributions to diyAudio forum have more than once prove ...
... A heartfelt thanks goes out to Nigel Goodwin, Don Booth and Joseph Raymond who assisted in proofreading this book. They should not however be held responsible for any errors or oversights. Another heartfelt thanks goes out to Hugh Dean, whose contributions to diyAudio forum have more than once prove ...
INA220-Q1 Automotive Grade, 26-V, I2C
... When the INA220-Q1 is in the normal operating mode (that is, MODE bits of the Configuration register are set to 111), it continuously converts the shunt voltage up to the number set in the shunt voltage averaging function (Configuration register, SADC bits). The device then converts the bus voltage ...
... When the INA220-Q1 is in the normal operating mode (that is, MODE bits of the Configuration register are set to 111), it continuously converts the shunt voltage up to the number set in the shunt voltage averaging function (Configuration register, SADC bits). The device then converts the bus voltage ...
3.3 volt logic characteristics and applications
... line noise. Because a FET is used, the output can be pulled all the way to GND, whereas a similar configuration with an NPN (as found in many competing technologies) would only pull-down to about 200mV, reducing noise immunity. The N-Channel pull-up FET quickly pulls the output voltage above the 2 v ...
... line noise. Because a FET is used, the output can be pulled all the way to GND, whereas a similar configuration with an NPN (as found in many competing technologies) would only pull-down to about 200mV, reducing noise immunity. The N-Channel pull-up FET quickly pulls the output voltage above the 2 v ...
Fundamentals Handbook
... If you’re installing a smaller UPS behind a larger UPS, you must consider the total potential power of the smaller UPS as well as other loads that will be powered by the larger UPS. For example, if you’re plugging a 1500 VA UPS into a 10,000 VA UPS, you must consider the load of the smaller UPS rath ...
... If you’re installing a smaller UPS behind a larger UPS, you must consider the total potential power of the smaller UPS as well as other loads that will be powered by the larger UPS. For example, if you’re plugging a 1500 VA UPS into a 10,000 VA UPS, you must consider the load of the smaller UPS rath ...
Practical Aspects of Rogowski Coil Applications to Relaying
... (CTs). The main difference between Rogowski Coils and CTs is that Rogowski Coil windings are wound over an (non-magnetic) air core, instead of over an iron core. As a result, Rogowski Coils are linear since the air core cannot saturate. However, the mutual coupling between the primary conductor and ...
... (CTs). The main difference between Rogowski Coils and CTs is that Rogowski Coil windings are wound over an (non-magnetic) air core, instead of over an iron core. As a result, Rogowski Coils are linear since the air core cannot saturate. However, the mutual coupling between the primary conductor and ...
R280-90-7
... Reliability comparisons between overhead and underground feeders and distribution systems present a unique problem. Underground installation is more costly than overhead. Since there is no exposure to wind, trees, or ice, an underground system has few transient faults. This means there is no need fo ...
... Reliability comparisons between overhead and underground feeders and distribution systems present a unique problem. Underground installation is more costly than overhead. Since there is no exposure to wind, trees, or ice, an underground system has few transient faults. This means there is no need fo ...
VS-UFB280FA20 Insulated Ultrafast Rectifier Module, 280 A
... Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vi ...
... Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vi ...
CD4067 CD4097
... In applications where separate power sources are used to drive VDD and the signal inputs, the VDD current capability should exceed VDD/RL (RL = effective external load). This provision avoids permanent current flow or clamp action on the VDD supply when power is applied or removed from the CD4067BMS ...
... In applications where separate power sources are used to drive VDD and the signal inputs, the VDD current capability should exceed VDD/RL (RL = effective external load). This provision avoids permanent current flow or clamp action on the VDD supply when power is applied or removed from the CD4067BMS ...
UM0708
... workspace. It is used to quickly evaluate both the MCU and the available tools. In addition, when used together with the STM8/128-MCKIT motor control starter kit and a PM motor, a motor can be made to run in a very short time. The BLDC library also eliminates the need for time-consuming development ...
... workspace. It is used to quickly evaluate both the MCU and the available tools. In addition, when used together with the STM8/128-MCKIT motor control starter kit and a PM motor, a motor can be made to run in a very short time. The BLDC library also eliminates the need for time-consuming development ...
ni elvis i
... will, at its option, repair or replace software media that do not execute programming instructions if National Instruments receives notice of such defects during the warranty period. National Instruments does not warrant that the operation of the software shall be uninterrupted or error free. A Retu ...
... will, at its option, repair or replace software media that do not execute programming instructions if National Instruments receives notice of such defects during the warranty period. National Instruments does not warrant that the operation of the software shall be uninterrupted or error free. A Retu ...
Section [26 33 53] [16611]
... maintenance bypass cabinet, hereafter referred to as the MBC, the battery system, UPS paralleling gear, external bypass static switch (EBS), and other such electrical distribution as described in this Section. 3. The UPS and associated equipment shall operate in conjunction with a primary power supp ...
... maintenance bypass cabinet, hereafter referred to as the MBC, the battery system, UPS paralleling gear, external bypass static switch (EBS), and other such electrical distribution as described in this Section. 3. The UPS and associated equipment shall operate in conjunction with a primary power supp ...