
1N5820 - Vishay
... Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vi ...
... Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vi ...
PD166017T1F Data Sheet INTELLIGENT POWER DEVICE
... Over temperature protection Shutdown with auto-restart on cooling Built-in diagnostic function Proportional load current sensing Defined fault signal in case of abnormal load condition Under voltage lock out Reverse battery protection by self turn on of N-ch MOSFET ...
... Over temperature protection Shutdown with auto-restart on cooling Built-in diagnostic function Proportional load current sensing Defined fault signal in case of abnormal load condition Under voltage lock out Reverse battery protection by self turn on of N-ch MOSFET ...
FJP5554 NPN Silicon Transistor FJP5554 — NPN Silicon T
... system whose failure to perform can be reasonably expected to intended for surgical implant into the body or (b) support or sustain cause the failure of the life support device or system, or to affect its life, and (c) whose failure to perform when properly used in safety or effectiveness. accordanc ...
... system whose failure to perform can be reasonably expected to intended for surgical implant into the body or (b) support or sustain cause the failure of the life support device or system, or to affect its life, and (c) whose failure to perform when properly used in safety or effectiveness. accordanc ...
MAX2023 High-Dynamic-Range, Direct Up-/Downconversion 1500MHz to 2500MHz Quadrature Mod/Demod General Description
... (MAX2023 Typical Application Circuit, when operated as a modulator, VCC = 4.75V to 5.25V, GND = 0V, I/Q differential inputs driven from a 100Ω DC-coupled source, 0V common-mode input, 50Ω LO and RF system impedance, R1 = 432Ω, R2 = 562Ω, R3 = 301Ω, TC = -40°C to +85°C. Typical values are at VCC = 5V ...
... (MAX2023 Typical Application Circuit, when operated as a modulator, VCC = 4.75V to 5.25V, GND = 0V, I/Q differential inputs driven from a 100Ω DC-coupled source, 0V common-mode input, 50Ω LO and RF system impedance, R1 = 432Ω, R2 = 562Ω, R3 = 301Ω, TC = -40°C to +85°C. Typical values are at VCC = 5V ...
SCCR Update Based on 2008 NEC ®
... assembly is equal to or greater than the system voltage. When devices such as slash rated circuit breakers or motor controllers (ie 480/277) are used, the entire assembly is also limited. Per 240.85 and 430.83(E), a device, which is slash voltage rated, limits the application of that device to only ...
... assembly is equal to or greater than the system voltage. When devices such as slash rated circuit breakers or motor controllers (ie 480/277) are used, the entire assembly is also limited. Per 240.85 and 430.83(E), a device, which is slash voltage rated, limits the application of that device to only ...
S203T Advanced Three-phase Network Analyzer VG VG VG
... In three-phase environments, measurements given above corresponding to any phase are available, other than the three-phase value (except the frequency of course). These measurements are rendered in both floating point and normalised format (except Frequency and Active energy) between 0..+10000 (-100 ...
... In three-phase environments, measurements given above corresponding to any phase are available, other than the three-phase value (except the frequency of course). These measurements are rendered in both floating point and normalised format (except Frequency and Active energy) between 0..+10000 (-100 ...
Si4356 - Silicon Labs
... Note: 1. R1 is required to minimize power up current. R1 is only necessary for pin configurations where SEL2 or SEL3 is mapped to GND. 2. An optional external low-pass RC filter may be connected to RX_DATA to filter the output and improve sensitivity. R2 and C7 should be selected to realize a cut-of ...
... Note: 1. R1 is required to minimize power up current. R1 is only necessary for pin configurations where SEL2 or SEL3 is mapped to GND. 2. An optional external low-pass RC filter may be connected to RX_DATA to filter the output and improve sensitivity. R2 and C7 should be selected to realize a cut-of ...
FFP08H60S 8 A, 600 V, Hyperfast II Diode F
... Distributors who are listed by country on our web page cited above. Products customers buy either from Fairchild directly or from Authorized Fairchild Distributors are genuine parts, have full traceability, meet Fairchild’s quality standards for handing and storage and provide access to Fairchild’s ...
... Distributors who are listed by country on our web page cited above. Products customers buy either from Fairchild directly or from Authorized Fairchild Distributors are genuine parts, have full traceability, meet Fairchild’s quality standards for handing and storage and provide access to Fairchild’s ...
Solar Electric Product Catalog
... installation of the inverter. There is an optional digital kWh meter with socket box (Part # 400010). Inverters come with standard 10-year warranties. Fronius offers the option to extend the warranty to 15-years. For three-phase installations, many SMA inverters are field configurable for 208 or 277 ...
... installation of the inverter. There is an optional digital kWh meter with socket box (Part # 400010). Inverters come with standard 10-year warranties. Fronius offers the option to extend the warranty to 15-years. For three-phase installations, many SMA inverters are field configurable for 208 or 277 ...
MAX5974A Evaluation Kit Evaluates: General Description Features
... the Ethernet data signals. PCB pads VDD and VSS are available for powering the EV kit if network connectivity is not required. The EV kit output voltage is configured for +5V and provides up to 4.7A output current while achieving up to 92% efficiency. Transformer T1 provides up to +1650V galvanic is ...
... the Ethernet data signals. PCB pads VDD and VSS are available for powering the EV kit if network connectivity is not required. The EV kit output voltage is configured for +5V and provides up to 4.7A output current while achieving up to 92% efficiency. Transformer T1 provides up to +1650V galvanic is ...
SUGGESTED SPECIFICATION for ASCO 7000 Series Soft Load
... in the event the source connected to load becomes unacceptable. An unacceptable source would be when their measured values are below the dropout or above the trip settings listed above. B. Repetitive accuracy of all settings shall be within ± 0.5 % over an operating temperature range of -20 C to 60 ...
... in the event the source connected to load becomes unacceptable. An unacceptable source would be when their measured values are below the dropout or above the trip settings listed above. B. Repetitive accuracy of all settings shall be within ± 0.5 % over an operating temperature range of -20 C to 60 ...
- Victoria Institution (College)
... 5. The Bidder should have valid CST/State VAT/TIN registration certificate. A copy of which should be enclosed. 6. Overall Average Annual Turnover of the Company/Firm/Corporation in the last two financial years should be at least 1.00crore.This must be the individual Company’s turnover and not that ...
... 5. The Bidder should have valid CST/State VAT/TIN registration certificate. A copy of which should be enclosed. 6. Overall Average Annual Turnover of the Company/Firm/Corporation in the last two financial years should be at least 1.00crore.This must be the individual Company’s turnover and not that ...
AN67 - Linear Technology Magazine Circuit Collection, Volume III
... is an application area for which the LTC1257 is appropriate. Autoranging is especially useful when using an ADC with multiplexed inputs. Without autoranging only two reference values are used: one to set the full-scale magnitude and another to set the zero scale magnitude. Since it is common to have ...
... is an application area for which the LTC1257 is appropriate. Autoranging is especially useful when using an ADC with multiplexed inputs. Without autoranging only two reference values are used: one to set the full-scale magnitude and another to set the zero scale magnitude. Since it is common to have ...
SIOV metal oxide varistors, General technical information
... circuit designers may generally want to know about the largest possible leakage current at given operating voltage. Therefore the lower limit of the tolerance band is shown. Righthand part of the curve (> 1 mA): This segment covers the “low-resistance” mode in an overvoltage event, where the circuit ...
... circuit designers may generally want to know about the largest possible leakage current at given operating voltage. Therefore the lower limit of the tolerance band is shown. Righthand part of the curve (> 1 mA): This segment covers the “low-resistance” mode in an overvoltage event, where the circuit ...
AN1290 Application Note How to Use the TDA911X and Improve Performances
... How to Use the TDA911X and Improve Performances TDA911x Deflection Processors at a Glance The TDA911x is a family of deflection processors for multisync monitors, incorporating horizontal and vertical processing, geometry correction, dynamic corrections (focus and/or brightness etc.), DC/DC conversi ...
... How to Use the TDA911X and Improve Performances TDA911x Deflection Processors at a Glance The TDA911x is a family of deflection processors for multisync monitors, incorporating horizontal and vertical processing, geometry correction, dynamic corrections (focus and/or brightness etc.), DC/DC conversi ...
Motor - Schneider Electric
... the inrush current may generate a voltage drop at the terminals of the motor the distance between the motor starter and the motor has no influence on motor starting motor starting through an auto-transformer is always a cycle of three steps it is possible to continuously operate an auto transformer ...
... the inrush current may generate a voltage drop at the terminals of the motor the distance between the motor starter and the motor has no influence on motor starting motor starting through an auto-transformer is always a cycle of three steps it is possible to continuously operate an auto transformer ...
LTM4628 - Dual 8A or Single 16A DC/DC uModule Regulator
... current source. When one channel is configured to be master of the two channels, then a capacitor from this pin to ground will set a soft-start ramp rate. The remaining channel can be set up as the slave, and have the master’s output applied through a voltage divider to the slave output’s track pin. ...
... current source. When one channel is configured to be master of the two channels, then a capacitor from this pin to ground will set a soft-start ramp rate. The remaining channel can be set up as the slave, and have the master’s output applied through a voltage divider to the slave output’s track pin. ...
NEW TRIACS: IS THE SNUBBER CIRCUIT NECESSARY?
... When driving an inductive load, triacs are designed with RC snubber. These commutation aid networks are badly optimized in most of applications. The subject of this paper is, first of all, to analyze the functions of snubber circuits for triacs and to propose calculation methods. But today snubber c ...
... When driving an inductive load, triacs are designed with RC snubber. These commutation aid networks are badly optimized in most of applications. The subject of this paper is, first of all, to analyze the functions of snubber circuits for triacs and to propose calculation methods. But today snubber c ...
SP481E 数据资料DataSheet下载
... potential on the person discharges through an arcing path to the rear panel of the system before he or she even touches the system. This energy, whether discharged directly or through air, is predominantly a function of the discharge current rather than the discharge voltage. Variables with an air d ...
... potential on the person discharges through an arcing path to the rear panel of the system before he or she even touches the system. This energy, whether discharged directly or through air, is predominantly a function of the discharge current rather than the discharge voltage. Variables with an air d ...