• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
An Improved Topology for Symmetric, Asymmetric and
An Improved Topology for Symmetric, Asymmetric and

... consists of a series-connected main high-, medium- and low-voltage stages. The high-voltage stage is made of a three-phase, six-switch inverter. The medium- and lowvoltage stages are made of three-level inverters constructed by H-bridge units. The proposed control strategy assumes a reference input ...
04.AnalyzingSeriesCircuitsWNotes
04.AnalyzingSeriesCircuitsWNotes

... 3. A 100 Ohm, a 47 Ohm, a 50 Ohm and an 20 Ohm resistor are wired in series with a 20 Volt Power supply during a lab. Draw your schematic diagram, including where you would place an ammeter to measure the total current, and a volt meter to measure the voltage across the 47 Ohm resistor. Complete the ...
Power Quality Counts
Power Quality Counts

... Application Note ...
design and construction of an automatic voltage
design and construction of an automatic voltage

Chapter 22 notes
Chapter 22 notes

... resonance: a peaking of the current amplitude at a certain frequency in a constant voltage circuit. resonance angular frequency : the angular frequency ω0 at which the resonance peak occurs. The inductive and capacitive reactance are equal at the resonance angular frequency so ...
ADC issues - TI E2E Community
ADC issues - TI E2E Community

4CX400A Russian Tubes for the MLA-2500 Amplifier By: B.
4CX400A Russian Tubes for the MLA-2500 Amplifier By: B.

... Before sealing the G-10 to the side panels, plug the 4CX400As into the sockets. Attempt to remove them using only a hold on the plate cap and a limited rocking motion no larger than the holes in the G-10. If you can't remove the tubes this way, carefully loosen the tension caused by the SK2A socket. ...
PPT
PPT

... • Output is a function of the inputs only • Similar to a pure function in mathematics, y=f(x). No way to store information, no side effects • If we change X, Y will change immediately (after a short delay) • Very important: This is not like a function call! f is active and doing what it does continu ...
Conductivity
Conductivity

... 1. Look at filter frequency response and estimate the undamped natural frequency and damping coefficient. Also check the stability. 2. Check out noise at the input and output of the filter. Is the noise less at the output, why or why not? 3. Find the transfer function from the schematic. 4. Determin ...
I41045662
I41045662

... by a fault in the utility system, a fault within the customer’s facility or a large increase of the load current, like starting a motor or transformer energizing. Typical faults are single-phase or multiple-phase short circuits, which leads to high currents. The high current results in a voltage dro ...
Development of a Picosecond-resolution TDC for
Development of a Picosecond-resolution TDC for

... the digitization would be done with a 5 GHz 10-bit counter, resulting in a least count of 1 ps. The second design we have simulated is a time-to-amplitude converter (TAC) with a sensitivity of 1mV/ps. The maximum input time interval of 1ns will convert to a 1.0V voltage that is held in a capacitor. ...
Preparation of Papers in Two-Column Format for the Proceedings of
Preparation of Papers in Two-Column Format for the Proceedings of

... One method of solution is to use Kirchhoff's and Ohm's laws. The first step in this approach is to label the directions of voltage-drop and currentdrop measurements for all resistors. Note that the measurements, if not specified, may be in either direction, although the arrow for the current measure ...
Reverse polarity and overvoltage protection
Reverse polarity and overvoltage protection

Fairchild Semiconductor`s
Fairchild Semiconductor`s

... such as solar inverters, welding machines and uninterruptible power supplies (UPS). Featuring extremely low saturation voltage (VCE(sat), Typ. = 1.1 V), the FGH30N60LSD is specially designed to increase system efficiency while meeting low-frequency requirements. For further energy efficiency in indu ...
AE4301167171
AE4301167171

EX: Find the numerical value of v2 in the circuit below. Show all work
EX: Find the numerical value of v2 in the circuit below. Show all work

... One method of solution is to use Kirchhoff's and Ohm's laws. The first step in this approach is to label the directions of voltage-drop and currentdrop measurements for all resistors. Note that the measurements, if not specified, may be in either direction, although the arrow for the current measure ...
DC-link Voltage Control using a TI DSP. National Center of
DC-link Voltage Control using a TI DSP. National Center of

... the advancement of power electronics, which has permitted the development of efficient and low cost WECS in the last decades. A WECS configuration that has great attention is based on a doubly fed induction generator (DFIG) and a back to back (B2B) converter, the back to back converter is constitute ...
Jamming Wireless 101
Jamming Wireless 101

011011014b
011011014b

... .18um CMOS process parameter provided by Mosis. Supply voltage used were ±1.5V. The simulation result shows that its frequency response is 26.73 GHz. Its power dissipation observed is ...
Two low power LED flashers
Two low power LED flashers

... experiments and gadgets. For examples see the experiments below: shake-a-gen rectifier and storage device sea water battery Although they are cheap and available there seem to be so many different types how do you know which one to use? The purpose of this little article is to compare a number of co ...
Field Testing Morningstar SunGuard Controllers
Field Testing Morningstar SunGuard Controllers

... Notes: • This testing procedure was developed for use in field conditions where no external power sources are available. • Due to the construction of the SunGuard controllers, it is possible only to determine whether the unit is functioning properly. It is not always apparent what component has fail ...
frs thomson 3-5800 technical description
frs thomson 3-5800 technical description

... The received signal from the antenna is band limited to 600 MHz by the transmitter harmonic filter. The desired signal is fed to a low noise amplifier (LNA – Q6) centered 440MHz at provides approximately 10 dB of gain. The output of the LNA is filtered with a Band Pass filter (SF1) with pass-band of ...
ZFAD SERIES
ZFAD SERIES

Power Quality Counts
Power Quality Counts

... Application Note ...
Sunmodule Plus 285W mono
Sunmodule Plus 285W mono

... Fully-automated production lines and seamless monitoring of the process and material ensure the quality that the company sets as its benchmark for its sites worldwide. SolarWorld Plus-Sorting Plus-Sorting guarantees highest system efficiency. SolarWorld only delivers modules that have greater than o ...
< 1 ... 1167 1168 1169 1170 1171 1172 1173 1174 1175 ... 1265 >

Islanding

Islanding refers to the condition in which a distributed generator (DG) continues to power a location even though electrical grid power from the electric utility is no longer present. Islanding can be dangerous to utility workers, who may not realize that a circuit is still powered, and it may prevent automatic re-connection of devices. For that reason, distributed generators must detect islanding and immediately stop producing power; this is referred to as anti-islanding.The common example of islanding is a grid supply line that has solar panels attached to it. In the case of a blackout, the solar panels will continue to deliver power as long as irradiance is sufficient. In this case, the supply line becomes an ""island"" with power surrounded by a ""sea"" of unpowered lines. For this reason, solar inverters that are designed to supply power to the grid are generally required to have some sort of automatic anti-islanding circuitry in them.In intentional islanding, the generator disconnects from the grid, and forces the distributed generator to power the local circuit. This is often used as a power backup system for buildings that normally sell their excess power to the grid.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report