• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
AN ADVANCED FACTS CONTROLLER FOR POWER FLOW
AN ADVANCED FACTS CONTROLLER FOR POWER FLOW

... transmission network capable of delivering contracted power from suppliers to consumers over large geographic area under market forces-controlled, and continuously varying patterns of demand and supply. Flexible AC Transmission Systems (FACTS) are being popularly used by utilities due to their capab ...
Mains Electricity
Mains Electricity

... at any point in the electricity supply system but the voltage varies in different parts of the national grid. The voltage of mains electricity supplied to UK homes is 230 V. This is an effective voltage which is equal to the voltage of a d.c. supply that would produce the same heating effect. The pe ...
RB-Pol-214 12V Step-Up Voltage Regulator U3V12F12 Description
RB-Pol-214 12V Step-Up Voltage Regulator U3V12F12 Description

Analizzatore qualità di rete classe S, Cos FI, Wattmetro,registratore
Analizzatore qualità di rete classe S, Cos FI, Wattmetro,registratore

... downloading, view, analysis of recorded data and professional report creation; • Flexible clamps (without additional power supply) are included in the Euro set. ...
50W - 100W, Rugged, Ultra-compact, Industrial DC/DC Converter
50W - 100W, Rugged, Ultra-compact, Industrial DC/DC Converter

... applications requiring higher immunity to shock, vibration and humidity. Customized, potted versions, are also available. This series is suitable for building complex, multi-output DC/DC systems with virtually no NRE cost. Multiple output versions with two, three or four outputs are also available. ...
Auxiliary Power Supply for Metro Application
Auxiliary Power Supply for Metro Application

... an additional transformer. This solution allows the supply of singlephase loads of another voltage level. In case of the Metro Kaohsiung project the single-phase AC voltage output has a nominal voltage of 1x 110 V AC, 60 Hz. The air conditioning systems are the main consumers of electric power. Air ...
Product Overview
Product Overview

... If a grid fault occurs which requires the VRB-ESS® to trip off line it will remain offline until instructed to reconnect in accordance with utility grid codes. Communication implementation between VRB-ESS® and Purchaser’s supervisory system for data collection may be established; extra hardware to a ...
EVO 160-200
EVO 160-200

Example - s3.amazonaws.com
Example - s3.amazonaws.com

... • The Y generator is balanced with an abc phase sequence and Van = 480 V • Each of the 3 lines (between source and load) has an impedance of 2 + j4 ohms • The  load is balanced where each of the three loads have an impedance of 60 + j90 ohms ...
EEE 120-3741
EEE 120-3741

... ** Assistant Professor, Electronics & Communications Engineering, CMR Engineering College, Hyderabad *** Professor & Principal, CMR Engineering College, Hyderabad ...
T. Moy, W. Rieutort-Louis, Y. Hu, L. Huang, J. Sanz-Robinson, J.C. Sturm, S. Wagner, and N. Verma, "Thin-film Circuits for Scalable Interfacing Between Large-area Electronics and CMOS ICs", Device Research Conference (DRC), (2014).
T. Moy, W. Rieutort-Louis, Y. Hu, L. Huang, J. Sanz-Robinson, J.C. Sturm, S. Wagner, and N. Verma, "Thin-film Circuits for Scalable Interfacing Between Large-area Electronics and CMOS ICs", Device Research Conference (DRC), (2014).

protection_from_ligh..
protection_from_ligh..

... – Electronic circuits damaged by high current or voltage caused by that current. • If lightning occurs near an overhead electric or telephone line, large current induced or injected into the line. • Charge can also be injected into soil. Arcing to nearby buried conductors at distances up to 100 m. ...
Schmitt Trigger
Schmitt Trigger

Complete Paper - Research Publish Journals
Complete Paper - Research Publish Journals

... and switching over from utility supply to generator in cases of utility power failure as well as when the supply is restored. With the intervention of electronics, these entire processes can be achieved in a faster and more efficient manner with little or no risk of damage to equipments. This paper ...
ZXTN2010A 60V NPN LOW SATURATION MEDIUM POWER TRANSISTOR IN E-LINE SUMMARY BV
ZXTN2010A 60V NPN LOW SATURATION MEDIUM POWER TRANSISTOR IN E-LINE SUMMARY BV

... Fax: (49) 89 45 49 49 49 [email protected] ...
A Proposed Broadband Power Line Communication System
A Proposed Broadband Power Line Communication System

... time monitoring and reaction of events on the Grid, anticipation of upcoming events, and problem isolation. In order to realize the Smart Grid, data are gathered from large numbers of intelligent sensors and processors installed on the power lines and equipment of the distribution grid (e.g. switche ...
Linear Circuits In linear circuits, voltage is proportional to the current
Linear Circuits In linear circuits, voltage is proportional to the current

... Power supply ...
SolarQuestÒ es una empresa que desarrolla equipo de alta
SolarQuestÒ es una empresa que desarrolla equipo de alta

... within the time frame specified. We have installed an experimental Power Management System in our facilities at Santa Cruz, California. Our Power Management System has been customized to match our solar powered, grid-backup energy system, and we have also included climate measurements. This informat ...
Vacuum Contactors
Vacuum Contactors

... CPX:our most compact design for 3.6kV applications CLX: for motor starters up to 7.2 kV,offering front access to terminals with its slim line ● CBX: a cubic arrangement for 7.2 kV&12 kV applications ○ Single-phase or three-phase ○ Mechanical interlock between two contactors for motor reverse command ...
Document
Document

Texas Instruments Integrated Power Conference
Texas Instruments Integrated Power Conference

... Off trajectories converge to 60V, 15A point, because this is the value of the input voltage and the load ...
Final Draft Standards Inverters ed 2
Final Draft Standards Inverters ed 2

... these standards does not endanger the safety of person or property when properly installed, maintained, and used in applications for which it was intended. ...
VersaNode 210
VersaNode 210

... support ‘dual boot’ capabilities with both the ISA100 and WirelessHART stacks on the same hardware, the VN210 allows customers to minimize the cost of design, field deployment, and testing. The VN210, in conjunction with a standards based router such as the VersaRouter 900, enables users to wireless ...
Dynamic VAR`s [D-VAR]
Dynamic VAR`s [D-VAR]

... • Instantaneously injects precise amounts of reactive power into a network • Can be seamlessly integrated with static shunt devices as part of a larger solution ...
Lecture_15_SRAM_52
Lecture_15_SRAM_52

... A shmoo plot is a graph that represents how a particular test passes or fails when parameters like frequency, voltage, or temperature are varied and the test is executed repeatedly. The shape of the failing region is meaningful and helps in determining the cause of the failure. A shmoo plot of norma ...
< 1 ... 1142 1143 1144 1145 1146 1147 1148 1149 1150 ... 1265 >

Islanding

Islanding refers to the condition in which a distributed generator (DG) continues to power a location even though electrical grid power from the electric utility is no longer present. Islanding can be dangerous to utility workers, who may not realize that a circuit is still powered, and it may prevent automatic re-connection of devices. For that reason, distributed generators must detect islanding and immediately stop producing power; this is referred to as anti-islanding.The common example of islanding is a grid supply line that has solar panels attached to it. In the case of a blackout, the solar panels will continue to deliver power as long as irradiance is sufficient. In this case, the supply line becomes an ""island"" with power surrounded by a ""sea"" of unpowered lines. For this reason, solar inverters that are designed to supply power to the grid are generally required to have some sort of automatic anti-islanding circuitry in them.In intentional islanding, the generator disconnects from the grid, and forces the distributed generator to power the local circuit. This is often used as a power backup system for buildings that normally sell their excess power to the grid.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report