• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
How to read a signal averaged electrocardiogram at Musgrove
How to read a signal averaged electrocardiogram at Musgrove

... can identify patients at low risk. We now have the capacity to undertake SAECGs at Musgrove and these can be performed by the ECG technicians. Time domain analyses are performed on a number of averaged beats. Frequency domain analysis is not yet validated. See the GE Healthcare poster for more infor ...
3366 External Power Supply
3366 External Power Supply

... The COM loop address is set with an Address setting tool 3314. The unit has an address label where the address is to be written. 3314 is also used to set the mode: NORMAL mode: This mode can be used in systems EBL128, EBL512 with S/W version > 2.3 and EBL512 G3. 2330 mode: This mode is used in syste ...
TRANSDUCER CONDITIONING INTERFACE output of this unit provides a direct
TRANSDUCER CONDITIONING INTERFACE output of this unit provides a direct

... channel. It has been developed with technical and functional features particularly suitable to convert a position measurement in a signal compatible with most of the analog cards for data acquisition. The ...
Aalborg Universitet A generic inertia emulation controller for multi-terminal VSC-HVDC systems
Aalborg Universitet A generic inertia emulation controller for multi-terminal VSC-HVDC systems

... frequency is a global indicator of the active power generation and demand. Any short-term active power imbalance results an instantaneous rate of change of frequency, where system inertia plays an important role in determining the sensitivity of frequency deviation under these power imbalances. High ...
J31066073
J31066073

View/Download-PDF - International Journal of Computer Science
View/Download-PDF - International Journal of Computer Science

... Simulation model for three phase T-source inverter was designed by using MATLAB/SIMULINK software.fig.1.5-1.8 shows output voltage, current, operating pulse, phase voltage of T-source inverter with maximum boost control technique. In this model input voltage of 100V is boosted upto 325V by shoot thr ...
Home Inverter Home inverter is to provide uninterruptible power to
Home Inverter Home inverter is to provide uninterruptible power to

ILLUMINEX Series
ILLUMINEX Series

... causing loss of normal lighting even though a total power failure has not occurred. Low Voltage Disconnect When the battery’s terminal voltage falls below predetermined levels, the low-voltage circuit disconnects the emergency lighting load. The disconnect remains in effect until normal power is res ...
TS19751 - Taiwan Semiconductor
TS19751 - Taiwan Semiconductor

... 1. Stresses listed as the above “Absolute Maximum Ratings” may cause permanent damage to the device. These are for stress ratings. Functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to ...
additional maximum voltage and maximum power transfer conditions
additional maximum voltage and maximum power transfer conditions

C7/C9 LED Retrofits Instructions
C7/C9 LED Retrofits Instructions

... incandescent  lamps.  The  challenge  in  designing  with  LEDs  is  that  they  run  on  very  low   voltage  -­‐  typically  3.5VDC  for  a  white  LED.  To  reduce  the  120VAC  line  voltage  to  a  few   volts,  the  manufactur ...


... flexible installation options, and durability are required. ...
Brought to you by Jestine Yong
Brought to you by Jestine Yong

... Troubleshooting linear power supply was quite easy as compare to switch mode power supplies (SMPS). AC voltage enters to the primary side of linear transformer and then converted the AC into a lower or higher AC voltage depending on the secondary winding. The output AC voltage is then rectified and ...
Aalborg Universitet Connected Modes
Aalborg Universitet Connected Modes

P5 – Electric Circuits
P5 – Electric Circuits

TIP125/126/127 PNP Epitaxial Darlington Transistor
TIP125/126/127 PNP Epitaxial Darlington Transistor

Twisted Pear Audio - Legato User Manual v1.0.2
Twisted Pear Audio - Legato User Manual v1.0.2

... discrete single-ended Class-A buffers. With the stock parts it is only recommended to use the buffers if your load is less than 4K. The module is designed to stack with the Buffalo II using mezzanine connectors (male and female pin headers). The supplied parts provide a 1st-order low pass filter wit ...
report docx
report docx

... transistors, the inverter fails to function. For the other results we see that Tp is inversely proportional to the Vdd. It falls off in the expected shape for a reciprocal relationship. At voltages further from the point in which symmetric response was calculated (2.5) the propagation delays are les ...
487-079
487-079

... Modern electronic governors have the facility to operate in isochronous mode. In this mode, the load sensors on each of the governors are effectively linked together using load share lines. Any imbalance in active load between connected generators will cause a change to the regulating circuit in eac ...
Involves Mux and sense amplifier design - WSU EECS
Involves Mux and sense amplifier design - WSU EECS

...  When the wordline (wl) signal goes high, one bit line remains high and the other falls at a linear rate until wl goes low  The difference between the bit lines is feed into a voltagesensing latch-based amplifier that is triggered when the differential voltage exceeds a certain threshold ...
scope-guide-LabVIEW - inst.eecs.berkeley.edu
scope-guide-LabVIEW - inst.eecs.berkeley.edu

...  Shape: sine, square, or triangle waves. These are all mathematical functions of time.  Frequency: inverse of the period of the signal; units are cycles per second (Hz)  Amplitude: peak to peak value of the time-varying component of the signal  DC Offset: constant voltage added to the signal to ...
Aalborg Universitet Microgrids in Active Network Management-Part II
Aalborg Universitet Microgrids in Active Network Management-Part II

Stanford University
Stanford University

... hours or less, and within the input current limits specified. Provide means for on-line testing of UPS, including test points to allow adjusting and servicing. Provide means for testing static switch while load is bypassed to utility. Mean Time Between Failures: (60,000) (________) hours, minimum. C ...
Physics Tutorial: Inductance and Transformers
Physics Tutorial: Inductance and Transformers

... Transformers allow 240V to be stepped down to convenient levels for digital electronics (only a few volts) or for other low power applications (typically 12V). Transformers step the voltage up for transmission, as mentioned above, and down for safe distribution. Without transformers, the waste of el ...
Project - sunist
Project - sunist

< 1 ... 1093 1094 1095 1096 1097 1098 1099 1100 1101 ... 1265 >

Islanding

Islanding refers to the condition in which a distributed generator (DG) continues to power a location even though electrical grid power from the electric utility is no longer present. Islanding can be dangerous to utility workers, who may not realize that a circuit is still powered, and it may prevent automatic re-connection of devices. For that reason, distributed generators must detect islanding and immediately stop producing power; this is referred to as anti-islanding.The common example of islanding is a grid supply line that has solar panels attached to it. In the case of a blackout, the solar panels will continue to deliver power as long as irradiance is sufficient. In this case, the supply line becomes an ""island"" with power surrounded by a ""sea"" of unpowered lines. For this reason, solar inverters that are designed to supply power to the grid are generally required to have some sort of automatic anti-islanding circuitry in them.In intentional islanding, the generator disconnects from the grid, and forces the distributed generator to power the local circuit. This is often used as a power backup system for buildings that normally sell their excess power to the grid.