64-Position OTP Digital Potentiometer AD5171 FEATURES
... Devices offers device programming software that operates across Windows® 95 to XP platforms, including Windows NT. This software application effectively replaces the need for external I2C controllers or host processors and, therefore, significantly reduces the development time of the users. An AD517 ...
... Devices offers device programming software that operates across Windows® 95 to XP platforms, including Windows NT. This software application effectively replaces the need for external I2C controllers or host processors and, therefore, significantly reduces the development time of the users. An AD517 ...
1 AC Losses in High Temperature Superconductors under non –Sinusoidal Conditions
... AC loss calculation are usually based on consideration of the non-linear Maxwell equations in which a superconductor is simulated by a media with non-linear voltage current characteristic, in the general case which depends on a local magnetic field and a local temperature. Many investigations are de ...
... AC loss calculation are usually based on consideration of the non-linear Maxwell equations in which a superconductor is simulated by a media with non-linear voltage current characteristic, in the general case which depends on a local magnetic field and a local temperature. Many investigations are de ...
D43052327
... capacitive design of a microswitch it refers the RF signal is shorted to ground by a variable capacitor. In the Resistive design switch operates by creating an open or short in the transmission line. This paper reviews the progress in MEMS applications from a device perspective. It includes the desi ...
... capacitive design of a microswitch it refers the RF signal is shorted to ground by a variable capacitor. In the Resistive design switch operates by creating an open or short in the transmission line. This paper reviews the progress in MEMS applications from a device perspective. It includes the desi ...
TPS62260-Q1 数据资料 dataSheet 下载
... The TPS6226x devices are high-efficiency synchronous step-down dc-dc converters optimized for battery powered applications. It provides up to 600-mA output current from a single Li-Ion cell and is ideal to power mobile phones and other portable applications. With an wide input voltage range of 2 V t ...
... The TPS6226x devices are high-efficiency synchronous step-down dc-dc converters optimized for battery powered applications. It provides up to 600-mA output current from a single Li-Ion cell and is ideal to power mobile phones and other portable applications. With an wide input voltage range of 2 V t ...
Aluminum Electrolytic Capacitor Application Guide
... grown on the anode foil during a process called “formation.” Formation is accomplished by pulling the anode foil on rollers through an electrolyte bath and continuously applying a DC voltage between the bath and the foil. The voltage is 135% to 200% of the final capacitor’s rated voltage. The thickn ...
... grown on the anode foil during a process called “formation.” Formation is accomplished by pulling the anode foil on rollers through an electrolyte bath and continuously applying a DC voltage between the bath and the foil. The voltage is 135% to 200% of the final capacitor’s rated voltage. The thickn ...
Powerstroke Diesel IDM mod Doc
... modification, although it has given some very noticeable gains on most trucks. Stock trucks show the most gains, highly modified ones the least. Any gains are also very dependant on what condition the original IDM is in: If the original IDM is already modified, and the pulse gap is shorter than .36- ...
... modification, although it has given some very noticeable gains on most trucks. Stock trucks show the most gains, highly modified ones the least. Any gains are also very dependant on what condition the original IDM is in: If the original IDM is already modified, and the pulse gap is shorter than .36- ...
Series-Parallel Networks
... voltage V4. Because of the similarities between the networks of Figs. 7.1(a) and 7.1(e), and between 7.1(b) and 7.1(d), the networks drawn during the reduction phase are often used for the return path. Although all the details of the analysis were not described above, the general procedure for a num ...
... voltage V4. Because of the similarities between the networks of Figs. 7.1(a) and 7.1(e), and between 7.1(b) and 7.1(d), the networks drawn during the reduction phase are often used for the return path. Although all the details of the analysis were not described above, the general procedure for a num ...
MAX1533/MAX1537 High-Efficiency, 5x Output, Main Power-Supply Controllers for Notebook Computers General Description
... overlap occurs, compared to 180° out-of-phase regulators where the duty-cycle overlap occurs when the input drops below 10V. Output current sensing provides accurate current limit using a sense resistor. Alternatively, power dissipation can be reduced using lossless inductor current sensing. Interna ...
... overlap occurs, compared to 180° out-of-phase regulators where the duty-cycle overlap occurs when the input drops below 10V. Output current sensing provides accurate current limit using a sense resistor. Alternatively, power dissipation can be reduced using lossless inductor current sensing. Interna ...
Ultra-low-noise large-bandwidth transimpedance amplifier
... capacitance (Cd), by the common mode input capacitances (C CM, CCM) and by the open-loop voltage gain AV,OP modeled, in turn, as a first-order dominant pole response (DC voltage gain AV0 and dominant pole time constant τ OP). The feedback resistor is modeled with its parasitic parallel ...
... capacitance (Cd), by the common mode input capacitances (C CM, CCM) and by the open-loop voltage gain AV,OP modeled, in turn, as a first-order dominant pole response (DC voltage gain AV0 and dominant pole time constant τ OP). The feedback resistor is modeled with its parasitic parallel ...
General Maintenance Manual
... Place alligator clips on the B+ terminal and the field terminal of the alternator. Run on machine for 10-15 seconds. If full resistance is achieved during this time, your alternator has correct current flow. It is accepting current (field) and producing current (B+). Replace the alternator if no res ...
... Place alligator clips on the B+ terminal and the field terminal of the alternator. Run on machine for 10-15 seconds. If full resistance is achieved during this time, your alternator has correct current flow. It is accepting current (field) and producing current (B+). Replace the alternator if no res ...
DXTN07100BP5 Features Mechanical Data
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
Cold-Junction Compensated Thermocouple-to-Digital Converter General Description Features
... complete serial-interface read of the cold-junction compensated thermocouple temperature requires 14 clock cycles. Thirty-two clock cycles are required to read both the thermocouple and reference junction temperatures (Table 2 and Table 3.) The first bit, D31, is the thermocouple temperature sign bi ...
... complete serial-interface read of the cold-junction compensated thermocouple temperature requires 14 clock cycles. Thirty-two clock cycles are required to read both the thermocouple and reference junction temperatures (Table 2 and Table 3.) The first bit, D31, is the thermocouple temperature sign bi ...
sleuth - I-Gard
... users to trace the faulted current all the way to the point of the fault, the automatic pulsing system found in the Sleuth™ system varies the low-level current pulses in the ground fault path. This does not adversely affect any electrical equipment. Locating a ground fault is easy with the use of th ...
... users to trace the faulted current all the way to the point of the fault, the automatic pulsing system found in the Sleuth™ system varies the low-level current pulses in the ground fault path. This does not adversely affect any electrical equipment. Locating a ground fault is easy with the use of th ...
WIDEBAND, LOW-DISTORTION FULLY DIFFERENTIAL AMPLIFIERS THS4502 THS4503 FEATURES
... junction temperature at or below 125°C for best performance and long term reliability. ...
... junction temperature at or below 125°C for best performance and long term reliability. ...
Merlin 350KW-400KW Large Portable Load Bank
... 3. Operate all hinged panels and doors for smooth and safe operation, try all latches and knobs. 4. Rotate and push all switches through all positions to ensure smooth operation. 5. Check cooling system by inspecting fan motor and blade. Slowly rotate blade by hand and note clearance of blade tip th ...
... 3. Operate all hinged panels and doors for smooth and safe operation, try all latches and knobs. 4. Rotate and push all switches through all positions to ensure smooth operation. 5. Check cooling system by inspecting fan motor and blade. Slowly rotate blade by hand and note clearance of blade tip th ...
FZT751Q Description Applications
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
YK CENTRIFUGAL LIQUID CHILLER OptiView Control Panel
... Programmable values and Navigation commands are subject to access level control. Display Only information is read-only parameters about unit operation. This information may be represented by a numerical value, a text string, or an LED image. For numerical values, if the monitored parameter is above ...
... Programmable values and Navigation commands are subject to access level control. Display Only information is read-only parameters about unit operation. This information may be represented by a numerical value, a text string, or an LED image. For numerical values, if the monitored parameter is above ...