LTC4006
... The LTC®4006 is a complete constant-current/constantvoltage charger controller for 2-, 3- or 4-cell lithium batteries in a small package using few external components. The PWM controller is a synchronous, quasi-constant frequency, constant off-time architecture that will not generate audible noise e ...
... The LTC®4006 is a complete constant-current/constantvoltage charger controller for 2-, 3- or 4-cell lithium batteries in a small package using few external components. The PWM controller is a synchronous, quasi-constant frequency, constant off-time architecture that will not generate audible noise e ...
MAX5180/MAX5183 Dual, 10-Bit, 40MHz, Current/Voltage Simultaneous-Output DACs General Description
... The MAX5180 contains two 10-bit, simultaneousupdate, current-output digital-to-analog converters (DACs) designed for superior performance in communications systems requiring analog signal reconstruction with low distortion and low-power operation. The MAX5183 provides equal specifications, with on-c ...
... The MAX5180 contains two 10-bit, simultaneousupdate, current-output digital-to-analog converters (DACs) designed for superior performance in communications systems requiring analog signal reconstruction with low distortion and low-power operation. The MAX5183 provides equal specifications, with on-c ...
ekonomski fakultet podgorica
... basics of diode rectifiers. Computer simulations are important in learning process and can provide additional support in better understanding not just of rectifiers but better understanding of different power electronics circuits. Three models of singe phase full- wave rectifier have been prepared f ...
... basics of diode rectifiers. Computer simulations are important in learning process and can provide additional support in better understanding not just of rectifiers but better understanding of different power electronics circuits. Three models of singe phase full- wave rectifier have been prepared f ...
NRD1-6_Rev.0110 - pes-psrc
... the frequency and voltage of the generator. See: manual synchronizing system, semiautomatic synchronizing system, synchronizing relay, synchronism check relay. Breaker-and-a-half. A configuration of three circuit breakers in series between two buses with a line, transformer, generator or other circu ...
... the frequency and voltage of the generator. See: manual synchronizing system, semiautomatic synchronizing system, synchronizing relay, synchronism check relay. Breaker-and-a-half. A configuration of three circuit breakers in series between two buses with a line, transformer, generator or other circu ...
IGC114T170S8RH
... Due to technical requirements, components may contain dangerous substances. For information on the types in question, please contact the nearest Infineon Technologies Office. Infineon Technologies components may be used in life-support devices or systems only with the express written approval of Inf ...
... Due to technical requirements, components may contain dangerous substances. For information on the types in question, please contact the nearest Infineon Technologies Office. Infineon Technologies components may be used in life-support devices or systems only with the express written approval of Inf ...
Maxwell`s Original Equations
... take the curl, we end up with the familiar partial time derivative form, curl E = −∂B/∂t. Heaviside referred to this partial time derivative curl equation as „Faraday‟s Law‟. Strictly speaking, it is not exactly Faraday‟s law because it doesn‟t cover for the convective aspect of electromagnetic indu ...
... take the curl, we end up with the familiar partial time derivative form, curl E = −∂B/∂t. Heaviside referred to this partial time derivative curl equation as „Faraday‟s Law‟. Strictly speaking, it is not exactly Faraday‟s law because it doesn‟t cover for the convective aspect of electromagnetic indu ...
Electrical Training Catalog
... terminology, installation and application. The course includes information on alternating current (AC) and direct current (DC) theory, power systems, circuits, motors, and generators; AC power and reactive components; batteries; AC and DC voltage regulators; transformers; and electrical test instrum ...
... terminology, installation and application. The course includes information on alternating current (AC) and direct current (DC) theory, power systems, circuits, motors, and generators; AC power and reactive components; batteries; AC and DC voltage regulators; transformers; and electrical test instrum ...
Increasing the Efficiency of a Single Phase Z
... input voltage without the need of a second input boosting stage. The ZSI also features fault tolerance capability (e.g. in case of DC-link shoot trough) which makes it ideal for operation in harsh environments as they are found in very small hydro-generators located in outlying regions. In previous ...
... input voltage without the need of a second input boosting stage. The ZSI also features fault tolerance capability (e.g. in case of DC-link shoot trough) which makes it ideal for operation in harsh environments as they are found in very small hydro-generators located in outlying regions. In previous ...
Guidelines for Providing Surge Protection Introduction
... diverts the energy to ground. An important concept about the SPD is that it is a sacrificial device with degradation of performance over time. It is considered to be at the end of its life when it has lost 10 percent of its design capacity. When selecting an SPD, there are many features to consider, ...
... diverts the energy to ground. An important concept about the SPD is that it is a sacrificial device with degradation of performance over time. It is considered to be at the end of its life when it has lost 10 percent of its design capacity. When selecting an SPD, there are many features to consider, ...
C a p a c ito rs - D S C C 9 3 0 2 6 a p p ro v e d , re lia b le o p e ra
... c) Ripple current ratings by part number at 85 °C and 40 kHz are included in the table. Ripple current correction factors for other temperatures and frequencies are given on the next page. d)Transient reverse voltage surges are acceptable under the following conditions: The peak reverse voltage does ...
... c) Ripple current ratings by part number at 85 °C and 40 kHz are included in the table. Ripple current correction factors for other temperatures and frequencies are given on the next page. d)Transient reverse voltage surges are acceptable under the following conditions: The peak reverse voltage does ...
Speedtronic Control Calibrator Handbook
... the sum of all currents to the summing junction is zero. 2. Many of the amplifiers used herein have integrating feedbacks. This means that, if the net current to the summing junction is negative, the output volts will continue to rise and conversely, a net positive summing junction current will caus ...
... the sum of all currents to the summing junction is zero. 2. Many of the amplifiers used herein have integrating feedbacks. This means that, if the net current to the summing junction is negative, the output volts will continue to rise and conversely, a net positive summing junction current will caus ...
Dual Power-Supply Supervisors
... an internal silicon-controlled rectifier (SCR) is triggered, providing 250-mA peak instantaneous current and 25-mA continuous current to the SCR gate drive terminal, which can drive an external high-current SCR gate or an overvoltage-warning circuit. The TL7770C series is characterized for operation ...
... an internal silicon-controlled rectifier (SCR) is triggered, providing 250-mA peak instantaneous current and 25-mA continuous current to the SCR gate drive terminal, which can drive an external high-current SCR gate or an overvoltage-warning circuit. The TL7770C series is characterized for operation ...
Transmission Planning Reliability Criteria - AEP PJM
... AEP steady state planning criteria requires that no bus voltage on AEP system shall exceed 1.05 per unit under system normal or contingency conditions. This voltage limit takes into consideration the equipment capabilities on AEP system. Short circuit assessment is performed assuming 1.05 per unit v ...
... AEP steady state planning criteria requires that no bus voltage on AEP system shall exceed 1.05 per unit under system normal or contingency conditions. This voltage limit takes into consideration the equipment capabilities on AEP system. Short circuit assessment is performed assuming 1.05 per unit v ...
AP5101 1.5A Step-Down Converter with 1.4MHz Switching Frequency
... The output voltage can be adjusted from 0.81V to 15V using an external resistor divider. Table 1 shows a list of resistor selection for common output voltages. Resistor R1 is selected based on a design tradeoff between efficiency and output voltage accuracy. For high values of R1 there is less curre ...
... The output voltage can be adjusted from 0.81V to 15V using an external resistor divider. Table 1 shows a list of resistor selection for common output voltages. Resistor R1 is selected based on a design tradeoff between efficiency and output voltage accuracy. For high values of R1 there is less curre ...