MAX5223 Low-Power, Dual, 8-Bit, Voltage Output Serial DAC in 8
... The MAX5223 contains two 8-bit, voltage output DACs. The DACs are “inverted” R-2R ladder networks. They use complementary switches that convert 8-bit digital inputs into equivalent analog output voltages in proportion to the applied reference voltage. The MAX5223 has one reference input that is shar ...
... The MAX5223 contains two 8-bit, voltage output DACs. The DACs are “inverted” R-2R ladder networks. They use complementary switches that convert 8-bit digital inputs into equivalent analog output voltages in proportion to the applied reference voltage. The MAX5223 has one reference input that is shar ...
MAX8566 High-Efficiency, 10A, PWM Internal-Switch Step-Down Regulator General Description
... switching frequencies greater than 1MHz possible, achieving all-ceramic-capacitor designs to minimize PC board space. The error amplifier works with Type 3 compensation to fully utilize the bandwidth of the highfrequency switching to obtain fast transient response. Adjustable soft-start time provide ...
... switching frequencies greater than 1MHz possible, achieving all-ceramic-capacitor designs to minimize PC board space. The error amplifier works with Type 3 compensation to fully utilize the bandwidth of the highfrequency switching to obtain fast transient response. Adjustable soft-start time provide ...
Operating manual Power Quality Analyser PQ-Box 100
... The PQ-Box 100 should not be opened for cleaning purposes. Do not use solvents for cleaning nor immerse the device in liquid. Caution: Don´t open the meter under any circumstances! The opening can result in electric shock. The PQ-Box 100 contains no user-serviceable parts. The maintenance and batter ...
... The PQ-Box 100 should not be opened for cleaning purposes. Do not use solvents for cleaning nor immerse the device in liquid. Caution: Don´t open the meter under any circumstances! The opening can result in electric shock. The PQ-Box 100 contains no user-serviceable parts. The maintenance and batter ...
LT1011/LT1011A - Voltage Comparator
... 4. Keep resistive source impedance as low as possible. If a resistor is added in series with one input to balance source impedances for DC accuracy, bypass it with a capacitor. The low input bias current of the LT1011 usually eliminates any need for source resistance balancing. A 5kΩ imbalance, for ...
... 4. Keep resistive source impedance as low as possible. If a resistor is added in series with one input to balance source impedances for DC accuracy, bypass it with a capacitor. The low input bias current of the LT1011 usually eliminates any need for source resistance balancing. A 5kΩ imbalance, for ...
Self -Excited DC Motor
... A commutator is a mechanical rectifier which converts the alternating voltage generated in the armature winding into direct voltage across the brushes. The commutator is made of copper segments insulated from each other by mica sheets and mounted on the shaft of the machine. The armature conductors ...
... A commutator is a mechanical rectifier which converts the alternating voltage generated in the armature winding into direct voltage across the brushes. The commutator is made of copper segments insulated from each other by mica sheets and mounted on the shaft of the machine. The armature conductors ...
Tektronix AM503 current probe system, user-manual
... Tektronix warrants that this product will be free from defects in materials and workmanship for a period of one (1) year from the date of shipment. If any such product proves defective during this warranty period, Tektronix, at its option, either will repair the defective product without charge for ...
... Tektronix warrants that this product will be free from defects in materials and workmanship for a period of one (1) year from the date of shipment. If any such product proves defective during this warranty period, Tektronix, at its option, either will repair the defective product without charge for ...
Synchronous operation of five-phase converters in linear modulation
... voltage of the five-phase system. So, its spectrum includes only odd (non fifth-order) harmonics for both continuous and discontinuous versions of synchronized PWM for any fundamental frequencies and for any (integer and fractional) ratios between the switching frequency and fundamental frequency. I ...
... voltage of the five-phase system. So, its spectrum includes only odd (non fifth-order) harmonics for both continuous and discontinuous versions of synchronized PWM for any fundamental frequencies and for any (integer and fractional) ratios between the switching frequency and fundamental frequency. I ...
ZXTC6718MC Features Mechanical Data
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
Low Voltage Performance of Multilayer Ceramic Capacitors
... Several experimental groups were then prepared in which the capacitors had physical flaws purposely induced. This was accomplished by subjecting the parts to severe thermal and mechanical shock so as to induce microcracks and/or macrocracks. The subjected shock treatment far exceeded any likely to b ...
... Several experimental groups were then prepared in which the capacitors had physical flaws purposely induced. This was accomplished by subjecting the parts to severe thermal and mechanical shock so as to induce microcracks and/or macrocracks. The subjected shock treatment far exceeded any likely to b ...
Silverstein™ Facial Nerve Monitor/Stimulator, Model S8 Service
... The pulse width of .0002 seconds has been found to be optimal for subcutaneous (intraoperative) stimulation. For transcutaneous stimulation, a pulse width of .0006 seconds is required, due to the skin barrier. Stimulators with a .0006 second pulse width are available from WR Medical Electronics. Sti ...
... The pulse width of .0002 seconds has been found to be optimal for subcutaneous (intraoperative) stimulation. For transcutaneous stimulation, a pulse width of .0006 seconds is required, due to the skin barrier. Stimulators with a .0006 second pulse width are available from WR Medical Electronics. Sti ...
Resistance Welding
... electric current. The electrodes also transmitt pressure required for formation of strong weld. Diameter of the weld spot is in the range 1/8” - 1/2” (3 - 12 mm). It consist of a transformer core having primary and secondary Winding. One end of secondary winding is connected to upper Electrode and o ...
... electric current. The electrodes also transmitt pressure required for formation of strong weld. Diameter of the weld spot is in the range 1/8” - 1/2” (3 - 12 mm). It consist of a transformer core having primary and secondary Winding. One end of secondary winding is connected to upper Electrode and o ...
A wide input voltage and load output variations fixed
... proposed for resonant converters [3]-[7], which permit the optimization of the converter’s magnetics, as well as its input and output filters. However, in order to achieve ZVS for a wide load variation, the converter must operate with a switching frequency much higher than the resonant frequency of ...
... proposed for resonant converters [3]-[7], which permit the optimization of the converter’s magnetics, as well as its input and output filters. However, in order to achieve ZVS for a wide load variation, the converter must operate with a switching frequency much higher than the resonant frequency of ...
transformer protection
... components and/or equipment involved. For example in the case of motors, a single motor overloaded by just 15% may experience less than 50% of its normal insulation life. Temporary overloads occur frequently. Common causes include temporary equipment overloads such as a machine tool taking too deep ...
... components and/or equipment involved. For example in the case of motors, a single motor overloaded by just 15% may experience less than 50% of its normal insulation life. Temporary overloads occur frequently. Common causes include temporary equipment overloads such as a machine tool taking too deep ...
Three-input Type Single Chip Inverter IC Application Note 【Rev 0】
... When the 15V_VCC voltage goes below the LVSD operating voltage (LVSDON), the output IGBTs of the top and bottom arms are all turned off regardless of the input signal. This function has hysteresis (Vrh). When the 15V_VCC voltage goes up again, the system returns to a state in which the ouput IGBT op ...
... When the 15V_VCC voltage goes below the LVSD operating voltage (LVSDON), the output IGBTs of the top and bottom arms are all turned off regardless of the input signal. This function has hysteresis (Vrh). When the 15V_VCC voltage goes up again, the system returns to a state in which the ouput IGBT op ...
DIGITAL MULTIMETER
... 1.2.2 Do not take measurements that exceed the protection limit values indicated in the specifications 1.2.3 Do not touch the metal tips of the test leads when the meter is connected to the circuit to be measured. ...
... 1.2.2 Do not take measurements that exceed the protection limit values indicated in the specifications 1.2.3 Do not touch the metal tips of the test leads when the meter is connected to the circuit to be measured. ...
AN2865
... – Phase 1: a current source (IDCH_SRC = 15 - 30 µA) is connected to the DP line. If at the end of this phase (100 ms min), both DP and DM lines are high, the detection proceeds to phase 2; – Phase 2: IDAT_SINK current sink (same as in current sink method, 50 - 100 µA) is connected to the DM line for ...
... – Phase 1: a current source (IDCH_SRC = 15 - 30 µA) is connected to the DP line. If at the end of this phase (100 ms min), both DP and DM lines are high, the detection proceeds to phase 2; – Phase 2: IDAT_SINK current sink (same as in current sink method, 50 - 100 µA) is connected to the DM line for ...
INA260 Precision Current and Power Monitor with Low
... The INA260 is a digital-output, current, power, and voltage monitor with an I2C and SMBus™-compatible interface with an integrated precision shunt resistor. It enables high-accuracy current and power measurements and over-current detection at common-mode voltages that can vary from 0 V to 36 V, inde ...
... The INA260 is a digital-output, current, power, and voltage monitor with an I2C and SMBus™-compatible interface with an integrated precision shunt resistor. It enables high-accuracy current and power measurements and over-current detection at common-mode voltages that can vary from 0 V to 36 V, inde ...
AP3154A
... The AP3154A is designed for white LED applications. An internal comparator circuit compares the voltage at each constant current sink input against a reference voltage. To ensure maximum power efficiency, the most appropriate switching mode (x1, x1.5, x2) is automatically selected. In applications, ...
... The AP3154A is designed for white LED applications. An internal comparator circuit compares the voltage at each constant current sink input against a reference voltage. To ensure maximum power efficiency, the most appropriate switching mode (x1, x1.5, x2) is automatically selected. In applications, ...